Literature DB >> 7874545

Results of the AO spinal internal fixator in the surgical treatment of thoracolumbar burst fractures.

S Akalm1, M Kiş, I T Benli, M Citak, E F Mumcu, M Tüzüner.   

Abstract

The potential for clinical instability following thoracolumbar fractures has evoked a progressive increase in interest in the surgical treatment of unstable thoracolumbar fractures. From September 1988 to October 1991, 44 thoracolumbar burst fractures were treated surgically by the AO Spinal Internal Fixator at the Orthopaedics and Traumatology Clinics of Ankara Social Security Hospital. Mean follow-up period was 28.8 (range 12-48) months. Fourteen (31.8%) of the patients were female, and 30 (68.2%) were male. Postoperatively, the mean anterior vertebral height loss and spinal canal compromise were corrected by 36.5% and 39.9%, respectively. Also, postoperatively 15.9% of improvement was obtained in the mean kyphosis angle. The mean compression angle, which was 19.5 degrees preoperatively, was corrected by 12.3 degrees and came to an average of 7.1 degrees postoperatively. In light of these data, it is suggested that the AO Spinal Internal Fixator effectively restores three-dimensional alignment of the spine and provides a rigid fixation.

Entities:  

Mesh:

Year:  1994        PMID: 7874545     DOI: 10.1007/bf02221448

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  34 in total

1.  Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae.

Authors:  D C George; M H Krag; C C Johnson; M E Van Hal; L D Haugh; L J Grobler
Journal:  Spine (Phila Pa 1976)       Date:  1991-02       Impact factor: 3.468

2.  Application and results of the AO internal fixation system in nontraumatic indications.

Authors:  D G Marchesi; J S Thalgott; M Aebi
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

3.  Burst fractures in the thoracic and lumbar spine. A clinico-neuropathologic analysis.

Authors:  J A Willen; U H Gaekwad; B A Kakulas
Journal:  Spine (Phila Pa 1976)       Date:  1989-12       Impact factor: 3.468

4.  Complications with the variable spinal plating system.

Authors:  T S Whitecloud; J C Butler; J L Cohen; P D Candelora
Journal:  Spine (Phila Pa 1976)       Date:  1989-04       Impact factor: 3.468

5.  Stabilization of the lower thoracic and lumbar spine with external skeletal fixation.

Authors:  F P Magerl
Journal:  Clin Orthop Relat Res       Date:  1984-10       Impact factor: 4.176

6.  Radiographic evaluation of thoracolumbar fractures.

Authors:  J S Keene
Journal:  Clin Orthop Relat Res       Date:  1984-10       Impact factor: 4.176

7.  Posterior fixation of thoracic and lumbar spine fractures using DC plates and pedicle screws.

Authors:  R C Sasso; H B Cotler; J D Reuben
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

8.  Effects of rigidity of an internal fixation device. A comprehensive biomechanical investigation.

Authors:  V K Goel; T H Lim; J Gwon; J Y Chen; J M Winterbottom; J B Park; J N Weinstein; J Y Ahn
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

9.  Analysis of 75 operated thoracolumbar fractures and fracture dislocations with and without neurological deficit.

Authors:  M Aebi; J Mohler; G Zäch; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1986

10.  An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing.

Authors:  M H Krag; B D Beynnon; M H Pope; J W Frymoyer; L D Haugh; D L Weaver
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

View more
  3 in total

1.  Thoracoscopic repair of thoracic spine trauma.

Authors:  H Hertlein; W H Hartl; H Dienemann; M Schürmann; G Lob
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

2.  Postoperative bedrest improves the alignment of thoracolumbar burst fractures treated with the AO spinal fixator.

Authors:  Yen Dang; David Yen; Wilma M Hopman
Journal:  Can J Surg       Date:  2009-06       Impact factor: 2.089

3.  Improved Monosegment Pedicle Instrumentation for Treatment of Thoracolumbar Incomplete Burst Fractures.

Authors:  Liehua Liu; Yibo Gan; Qiang Zhou; Haoming Wang; Fei Dai; Fei Luo; Tianyong Hou; Chengmin Zhang; Chen Zhao; Jinsong Zhang; Jianzhong Xu; Yingwen Lü
Journal:  Biomed Res Int       Date:  2015-05-04       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.