Literature DB >> 31741598

Applications of dual energy CT in clinical practice: A pictorial essay.

Parang S Sanghavi1, Bhavin G Jankharia1.   

Abstract

In dual-energy CT (DECT), two different x-ray spectra are used to acquire two image datasets of the same region, to allow the analysis of energy-dependent changes in the attenuation of different materials. Each type of material demonstrates a relatively specific change in attenuation between images obtained with a high-energy spectrum and those obtained with a low-energy spectrum. Based on the relatively specific change in attenuation with two different energies, material composition information can be obtained to allow tissue characterization. The DECT ability of material differentiation allows bone removal in various CT angiography studies and bone marrow edema depiction, while with material optimization, metal artefacts can be significantly reduced to almost nil. DECT allows material separation to differentiate uric acid crystals from calcium to determine the composition of urinary calculi and to diagnose gout. Using the DECT ability of material decomposition, iodine maps can be generated, which are useful in the evaluation of any enhancing lesion in the body without the need to obtain a plain scan and allow perfusion maps to be created in cases of pulmonary thromboembolism. Copyright:
© 2019 Indian Journal of Radiology and Imaging.

Entities:  

Keywords:  Dual energy CT; iodine map; material; metal artefact; uric acid

Year:  2019        PMID: 31741598      PMCID: PMC6857256          DOI: 10.4103/ijri.IJRI_241_19

Source DB:  PubMed          Journal:  Indian J Radiol Imaging        ISSN: 0970-2016


Introduction

In diagnostic imaging, the photoelectric effect is the most important mechanism by which the x-ray photons interact with matter. The chances of this effect increase as the energy of the x-ray beam approaches the K edge of the particular atom.[1] Different atoms have different K edge values and hence behave differently at different energies of the x-ray beam. In dual-energy CT, two different x-ray spectra are used to acquire two image datasets of the same anatomic region, allowing analysis of energy dependent changes in the attenuation of different materials.[2] Every material shows a relatively specific change in attenuation between images obtained with a high and a low-energy spectrum and this attenuation difference allows better characterization of the tissues. Two different materials that show similar attenuation on images acquired with one of the two energy spectra, may show substantial differences in their attenuation on the images acquired with the other spectrum and hence may be easily differentiated.[3] There are multiple techniques available for dual energy CT imaging which can be broadly classified as: Dual source DECT Single source DECT. Single source DECT can be further divided based on the exact mechanism to generate two different energy spectra as: Fast kV switching Dual layer detector Slow kV switching Dual spiral dual energy Twin beam dual energy. We use the Siemens Somatom Definition Edge CT scanner which is based upon a single source twin beam dual energy technique [Figure 1].
Figure 1

In twin beam DECT, two different filters Tin [Sn] and Gold (Au) are used to split the x-ray beam into two beams of different energies. The Gold (Au) filter, filters the high energy photons and produces a low energy beam while Tin (Sn) filter, filters the low energy photons and produces a high energy beam

In twin beam DECT, two different filters Tin [Sn] and Gold (Au) are used to split the x-ray beam into two beams of different energies. The Gold (Au) filter, filters the high energy photons and produces a low energy beam while Tin (Sn) filter, filters the low energy photons and produces a high energy beam In twin beam DECT, two different filters Tin [Sn] and Gold [Au] are used to split the x-ray beam from a single source into two beams of different energies. The greatest advantage of this technique over the many of the other techniques mentioned above is eliminating temporal mis-registration.

Applications in Clinical Practice

Material differentiation

Bone removal in angiography

As DECT has the ability to differentiate different materials from one another, calcium in the bones is readily separated from iodine in the contrast media. Hence the bones in any angiography study can be easily removed. This is particularly useful in cerebral [Figure 2] and lower limb angiography [Figures 3 and 4], where manual methods can be difficult and time consuming, especially when the vessels lie close to bones.[45] Similarly, calcified plaques can be removed for better visualisation of the lumen [Figure 5].
Figure 2 (A-C)

A routine cerebral CT angiography study (A) shows carotid and cerebral arteries overlapped by bones making it difficult to visualise them. With DECT bone removal tool, all the bones are effectively and selectively removed allowing clear visualisation of the arteries with AVM (arrow) as shown in this MIP image (B). Similarly the arteries with AVM (arrow) can also be evaluated in VRT image (C) with bone removal

Figure 3 (A-D)

A routine lower limb CT angiography study (A) shows arteries overlapped by the long bones. With DECT bone removal technique in MIP image (B), the right popliteal artery occlusion (arrow) is clearly visualised with distal reformation of the tibial artery seen via collateral circulation. Similarly left distal popliteal artery occlusion (short arrow) just at the level of its division is also seen. Similarly VRT images without (C) and with (D) bone removal also shows the pathologies (arrows) well

Figure 4 (A-C)

A lower limb CT angiography study (A) shows arteries overlap by bones. DECT bone removal technique VRT (B) and MIP (C) images shows the occlusion of the left superficial femoral artery (arrow) well with extensive collateral circulation and distal reformation of the popliteal and the tibial arteries (short arrow)

Figure 5 (A and B)

Same case as shown in Figure 4, also shows diffuse atherosclerotic wall calcification (arrows), compromising accurate lumen visualisation (A). With DECT calcium removal technique applied on VRT images (B) the calcium in the wall of the arteries is effectively removed, allowing the visualisation of the underlying lumen easily

A routine cerebral CT angiography study (A) shows carotid and cerebral arteries overlapped by bones making it difficult to visualise them. With DECT bone removal tool, all the bones are effectively and selectively removed allowing clear visualisation of the arteries with AVM (arrow) as shown in this MIP image (B). Similarly the arteries with AVM (arrow) can also be evaluated in VRT image (C) with bone removal A routine lower limb CT angiography study (A) shows arteries overlapped by the long bones. With DECT bone removal technique in MIP image (B), the right popliteal artery occlusion (arrow) is clearly visualised with distal reformation of the tibial artery seen via collateral circulation. Similarly left distal popliteal artery occlusion (short arrow) just at the level of its division is also seen. Similarly VRT images without (C) and with (D) bone removal also shows the pathologies (arrows) well A lower limb CT angiography study (A) shows arteries overlap by bones. DECT bone removal technique VRT (B) and MIP (C) images shows the occlusion of the left superficial femoral artery (arrow) well with extensive collateral circulation and distal reformation of the popliteal and the tibial arteries (short arrow) Same case as shown in Figure 4, also shows diffuse atherosclerotic wall calcification (arrows), compromising accurate lumen visualisation (A). With DECT calcium removal technique applied on VRT images (B) the calcium in the wall of the arteries is effectively removed, allowing the visualisation of the underlying lumen easily

Bone marrow edema

Bone marrow edema is best visualised on MRI imaging. However with DECT, it is now possible to evaluate bone marrow edema on CT scan as well. As DECT can differentiate calcium from other elements, it can also selectively remove calcium from the region of interest. This is called virtual non-calcium (VNC) technique and it allows visualisation of bone marrow edema.[6] Multiple studies have validated this technique for bone marrow edema detection.[78] It is especially useful in acute fractures where MRI may not be possible [Figures 6 and 7]. Kaup M et al.[9] demonstrated the utility of DECT for bone marrow edema evaluation in osteoporotic vertebral compression fractures and found that its diagnostic performance approached that of MRI.
Figure 6 (A-D)

CT image in coronal reconstruction (A) and 3D reconstruction (B) shows fractures (arrows) involving the neck and the greater tuberosity of the right humerus. With DECT, the bone marrow edema (arrows) can be seen in the the neck and the greater tuberosity of the humerus as seen in DECT coronal reconstruction (C) and DECT 3D reconstruction (D)

Figure 7 (A-C)

Another example of bone marrow edema seen with DECT, in a case of trauma to the right knee, 1 week ago. CT scan in axial (A) and coronal (B) reconstructions shows a linear undisplaced fracture (arrows) in the distal femur in the intercondylar region. DECT images (C) also shows mild residual edema (arrows) at the fracture site

CT image in coronal reconstruction (A) and 3D reconstruction (B) shows fractures (arrows) involving the neck and the greater tuberosity of the right humerus. With DECT, the bone marrow edema (arrows) can be seen in the the neck and the greater tuberosity of the humerus as seen in DECT coronal reconstruction (C) and DECT 3D reconstruction (D) Another example of bone marrow edema seen with DECT, in a case of trauma to the right knee, 1 week ago. CT scan in axial (A) and coronal (B) reconstructions shows a linear undisplaced fracture (arrows) in the distal femur in the intercondylar region. DECT images (C) also shows mild residual edema (arrows) at the fracture site

Material optimisation

Metal artefact reduction

Metal in prosthesis can cause significant artefacts and hamper evaluation of periprosthetic soft tissue. These metal artefacts are caused by beam hardening artefacts.[10] Radiographs are typically obtained post-operatively but they have low sensitivity and specificity.[11] MRI is a great tool to assess bone marrow edema and soft tissue lesions but the images are distorted by metal artefacts.[12] With the conventional CT, multiple techniques are available to reduce the metal artefacts.[13] Increasing in tube current, increasing voltage and reducing slice thickness can help reduce metal artefacts. Various modifications in reconstructions techniques like changing the deconvolution kernel from bone to soft tissue or smooth kernel, using interactive reconstructions and extending the Hounsfield unit scale from 4000 to 40000 HU can also help reduce metal artefacts. Using DECT, the artefacts from metal can be significantly reduced to almost nil. As the artefacts are more at lower energy x-ray beams, the monochromatic images at higher keV settings show significantly less artefacts. Additionally, iterative reconstruction protocols such as iMAR (interactive metal artefact reduction) can be used that further reduce the metal artefacts. When both the techniques are used together, the final result shows almost nil metal artefacts [Figures 8 and 9]. This allows the visualisation of periprosthetic soft tissue to identify complications such as periprosthetic osteolyis, fracture, infection, aseptic loosening, focal particle disease and tumor. Metal artefact reduction can also be used for evaluation of stents and to detect endoleak after aneurysm repair.[14]
Figure 8

In a known case of left total hip replacement, the conventional CT images shows extensive metal artefacts, compromising adequate visualisation of the bones and the soft tissue. With DECT, multiple reconstructions at various keV can be obtained and with progressively increasing keV, the metal artefacts keep reducing. Addition of iterative reconstruction (iMAR), further reduces metal artefacts and when both techniques are combined, the final image shows almost nil artefacts, allowing accurate evaluation of the bone and the soft tissue

Figure 9

Another example of metal artefact reduction in a patient with bilateral total hip replacement. Higher keV images shows less metal artefacts and addition of iterative reconstruction (iMAR) further reduces the metal artefacts and when both techniques are combined, the final image shows almost nil artefacts

In a known case of left total hip replacement, the conventional CT images shows extensive metal artefacts, compromising adequate visualisation of the bones and the soft tissue. With DECT, multiple reconstructions at various keV can be obtained and with progressively increasing keV, the metal artefacts keep reducing. Addition of iterative reconstruction (iMAR), further reduces metal artefacts and when both techniques are combined, the final image shows almost nil artefacts, allowing accurate evaluation of the bone and the soft tissue Another example of metal artefact reduction in a patient with bilateral total hip replacement. Higher keV images shows less metal artefacts and addition of iterative reconstruction (iMAR) further reduces the metal artefacts and when both techniques are combined, the final image shows almost nil artefacts

Material separation

DECT has the ability to separate different materials based on their specific dual energy ratio. Hence, uric acid crystal can be separated from calcium, both of which otherwise appears hyperdense on conventional single energy CT.

Urinary stones

As different types of renal calculi are treated differently, knowledge of the composition of stones may guide management decisions and predict the effectiveness of therapy. For example, uric acid calculi can be managed medically with urine alkalinization that facilitates dissolution, while non-uric acid calculi need other lines of treatment such as lithotripsy or surgery.[15] Using DECT, it is possible to differentiate uric acid from non-uric acid calculi. Keeping the dual energy ratio at 1.05, the uric acid stones lie below the line/slope and are coloured red, whereas the non-uric acid stones lie above the line/slope and are differently colour-coded (blue) [Figures 10 and 11].
Figure 10 (A-D)

The conventional CT images shows the calculi (arrows) in the kidney (A) and ureter (B) as hyperdense structures and their composition cannot be determined. With DECT uric acid calculus is shown in red (C) while non-uric acid calculus is shown as blue (D), allowing their differentiation. The graph also helps shows the two calculi differently, with the uric acid calculus lying below the line, and non-uric acid lying above

Figure 11 (A-C)

Another example of urinary calculi (arrows), two calculi are seen in the kidney in the CT scan image (A). DECT the calculus red (B) in colour and falling below the line (C), thus confirming uric acid calculi

The conventional CT images shows the calculi (arrows) in the kidney (A) and ureter (B) as hyperdense structures and their composition cannot be determined. With DECT uric acid calculus is shown in red (C) while non-uric acid calculus is shown as blue (D), allowing their differentiation. The graph also helps shows the two calculi differently, with the uric acid calculus lying below the line, and non-uric acid lying above Another example of urinary calculi (arrows), two calculi are seen in the kidney in the CT scan image (A). DECT the calculus red (B) in colour and falling below the line (C), thus confirming uric acid calculi

Gout

Gout is characterized by an inflammatory response to the deposition of monosodium urate (MSU) crystals in the joints and soft tissue, which leads to acute or chronic arthropathy and gouty tophi formation. Diagnosis can be made on clinical and biochemical bases, and definite diagnosis requires microscopic demonstration of MSU crystals from the aspiration of the joint fluid,[16] a method that is invasive and may have false negative results. Keeping the dual energy ratio specific to uric acid crystals, the uric acid crystals are coloured green, whereas calcium is coloured blue. The diagnosis of gout can be easily made, non-invasively [Figure 12].
Figure 12 (A and B)

A 35 years male presented with pain and swelling in right foot and wrist. Serum uric acid-13 mg/dl. Radiographs of both feet, knees and wrists (A) shows juxta-articular erosions (arrows) around right 1st metatarsophalangeal joint, right lateral femoral condyle, right distal ulna and 5th carpometacarpal joint with soft tissue. Diagnosis of gout was made. B. DECT (B) allows visualisation of the urate crystals seen as green coloured areas (arrows), confirming the diagnosis. Also, it shows involvement of the asymptomatic and radiographically occult areas and displays total tophus volume

A 35 years male presented with pain and swelling in right foot and wrist. Serum uric acid-13 mg/dl. Radiographs of both feet, knees and wrists (A) shows juxta-articular erosions (arrows) around right 1st metatarsophalangeal joint, right lateral femoral condyle, right distal ulna and 5th carpometacarpal joint with soft tissue. Diagnosis of gout was made. B. DECT (B) allows visualisation of the urate crystals seen as green coloured areas (arrows), confirming the diagnosis. Also, it shows involvement of the asymptomatic and radiographically occult areas and displays total tophus volume With DECT, it is also possible to quantify the overall tophus burden or volume of urate deposition without any user variability. Thus, makes DECT an ideal tool for evaluating any change in tophus burden and can be used for follow-up to document response to treatment[17] [Figure 13].
Figure 13 (A and B)

A 38 years female presented with bilateral knee pain with normal serum uric acid levels. The DECT (A) showed small foci of urate crystal deposition (arrows) in both the knees and the left foot, confirming the diagnosis of gout and the patient was put on treatment with allopurinol. The follow up DECT scan (B) post 2 months of treatment shows significant improvement and resolution of the urate crystals, suggestive of response to treatment

A 38 years female presented with bilateral knee pain with normal serum uric acid levels. The DECT (A) showed small foci of urate crystal deposition (arrows) in both the knees and the left foot, confirming the diagnosis of gout and the patient was put on treatment with allopurinol. The follow up DECT scan (B) post 2 months of treatment shows significant improvement and resolution of the urate crystals, suggestive of response to treatment

Material decomposition

Iodine maps

Lung Pulmonary Thromboembolism The dual energy iodine maps allow us to evaluate lung perfusion and hence are useful to demonstrate perfusion defects in cases of pulmonary thromboembolism. Additionally, the dual energy iodine maps also improve visualisation of filling defects/thrombi in a small segmental or subsegmental artery. Fink et al.[18] showed the sensitivity and specificity of dual-energy CT perfusion mapping for the assessment of pulmonary embolism to be 100% on a per patient basis and 60-66.7% and 99.5-99.8% on a per segment basis, as compared to CT angiography. In patients with pulmonary thromboembolism, the dual energy perfusion maps show peripheral wedge-shaped areas of reduced perfusion representing perfusion defects [Figure 14]. They are also very useful for the follow up of such patients who are treated with anticoagulants to demonstrate both a decrease in perfusion defects as well as the thrombi [Figures 15 and 16].
Figure 14 (A and B)

CT Pulmonary angiography (A) shows a saddle thrombus (arrows) involving both the pulmonary arteries and also extending into the right upper and lower lobe branches. The DECT perfusion maps (B) shows patchy perfusion defects (arrows) in the right upper and lower lobes

Figure 15 (A-E)

CT Pulmonary angiography axial (A) and coronal (B) images shows extensive bilateral pulmonary thromboembolism (arrows). The HRCT axial (C) image shows a developing infarct (arrow) in the posterior segment of the right upper lobe. The DECT images (D and E) shows perfusion defects (arrows) in the lung parenchyma bilaterally with the infarct in the right upper lobe

Figure 16 (A-E)

The follow up CT Pulmonary angiography axial (A) and coronal (B) images, after 3 months of anticoagulation treatment shows complete resolution of the bilateral pulmonary thromboembolism. The HRCT axial (C) image shows resolution of the infarct in the right upper lobe. The DECT images (D and E) shows reversal of the perfusion defects in the lung parenchyma bilaterally

CT Pulmonary angiography (A) shows a saddle thrombus (arrows) involving both the pulmonary arteries and also extending into the right upper and lower lobe branches. The DECT perfusion maps (B) shows patchy perfusion defects (arrows) in the right upper and lower lobes CT Pulmonary angiography axial (A) and coronal (B) images shows extensive bilateral pulmonary thromboembolism (arrows). The HRCT axial (C) image shows a developing infarct (arrow) in the posterior segment of the right upper lobe. The DECT images (D and E) shows perfusion defects (arrows) in the lung parenchyma bilaterally with the infarct in the right upper lobe The follow up CT Pulmonary angiography axial (A) and coronal (B) images, after 3 months of anticoagulation treatment shows complete resolution of the bilateral pulmonary thromboembolism. The HRCT axial (C) image shows resolution of the infarct in the right upper lobe. The DECT images (D and E) shows reversal of the perfusion defects in the lung parenchyma bilaterally One should keep in mind the areas where artefacts are commonly seen and should not misinterpret them as areas of perfusion defects. These artefactual perfusion defects are commonly seen in the upper lobes due to beam hardening artefacts, in the medial segment of the right middle lobe and lingula due to cardiac pulsation and in the lung bases due to diaphragmatic motion. The other common pitfall is apparent perfusion defects in an area of lung parenchyma with systemic arterial supply. Also, parenchymal diseases such as collapse, consolidation, masses and emphysema show perfusion defects.[19] Lung nodule With DECT a single contrast enhanced scan is sufficient to differentiate an enhancing nodule from calcification with the use of virtual nonenhanced image reconstructions.[20] The enhancing and non-enhancing components of a heterogeneous lesion are better appreciated on iodine maps, which also help target the appropriate area for biopsy, to increase the yield [Figure 17].
Figure 17 (A-D)

The plain HRCT (A) and contrast (B) axial images shows an ill-defined spiculated enhancing mass (arrow) in the right upper lobe with mediastinal lymphadenopathy (short arrow). The DECT axial images shows the more enhancing part with higher iodine uptake in the medial part of the mass (C), which can be targeted for biopsy, while the lateral part (D) shows relatively less enhancement

The plain HRCT (A) and contrast (B) axial images shows an ill-defined spiculated enhancing mass (arrow) in the right upper lobe with mediastinal lymphadenopathy (short arrow). The DECT axial images shows the more enhancing part with higher iodine uptake in the medial part of the mass (C), which can be targeted for biopsy, while the lateral part (D) shows relatively less enhancement Degree of contrast enhancement is an important factor to differentiate a benign from a malignant lesion.[21] Hence dual energy analysis with iodine maps is very useful in the evaluation of solitary or multiple pulmonary nodules. The enhancement in a nodule is not always easily appreciable on routine CT scan and DECT iodine maps help confirm or rule out enhancement conclusively [Figures 18 and 19].
Figure 18 (A and B)

The axial image (A) of the lungs shows a nodule (arrow) in the left lung with questionable enhancement. The DECT iodine map (B) help rule out enhancing nodule by showing no significant iodine uptake, hence suggestive of an old healed granuloma

Figure 19 (A-D)

DECT iodine maps (A, B and D) shows no significant iodine uptake in most of the nodules. Only one nodule (C) shows significant iodine uptake, worrisome for active nodule

The axial image (A) of the lungs shows a nodule (arrow) in the left lung with questionable enhancement. The DECT iodine map (B) help rule out enhancing nodule by showing no significant iodine uptake, hence suggestive of an old healed granuloma DECT iodine maps (A, B and D) shows no significant iodine uptake in most of the nodules. Only one nodule (C) shows significant iodine uptake, worrisome for active nodule Difference in the contrast wash out pattern of a metastatic nodule can be used to evaluate various types of primary malignant tumors. For example, metastases from colorectal carcinoma, malignant melanoma and thyroid carcinoma show a distinct wash out pattern whereas those from lung cancer, salivary gland cancer and sarcoma show increased enhancement in the delayed phase images.[22] Liver lesions A hypervascular lesion is more conspicuous on lower kV images on an arterial phase of the study, as iodine is more attenuating at lower energies.[23] DECT may be used to identify fat, iron, calcium, or hemorrhage within the tumor. Virtual non-enhanced images can be used to differentiate calcification in a lesion from enhancement. DECT iodine maps are especially useful in differentiating a simple cyst from a complex cyst as they show the subtle enhancement in the lesion very well, which is often difficult to appreciate on a single energy CT scan [Figures 20 and 21].
Figure 20 (A-D)

A 53 years female, treated case of carcinoma breast, came for follow up scan. The contrast enhanced abdomen image (D) shows a hypodense lesion (arrow) in the left lobe of the liver. The DECT iodine maps (A-C) shows significant iodine uptake (arrow) suggestive of an enhancing lesion, worrisome for metastatic disease, which was later proved with biopsy

Figure 21 (A-D)

The contrast enhanced abdomen image (D) shows a hypodense lesion (arrow) in the left lobe of the liver. The DECT iodine maps (A-C) shows no significant iodine uptake (arrow) suggestive of a simple cyst

A 53 years female, treated case of carcinoma breast, came for follow up scan. The contrast enhanced abdomen image (D) shows a hypodense lesion (arrow) in the left lobe of the liver. The DECT iodine maps (A-C) shows significant iodine uptake (arrow) suggestive of an enhancing lesion, worrisome for metastatic disease, which was later proved with biopsy The contrast enhanced abdomen image (D) shows a hypodense lesion (arrow) in the left lobe of the liver. The DECT iodine maps (A-C) shows no significant iodine uptake (arrow) suggestive of a simple cyst Kidney lesions DECT is useful in differentiating a hyperdense cyst from an enhancing solid tumor. A hyperdense cyst containing proteinaceous material or blood products may mimic a solid enhancing tumor on a contrast enhanced scan. In such situations, iodine maps help as a hyperdense cyst will not show iodine uptake. Also, virtual non-enhanced images will show hyperdense contents in the cyst. Similarly, enhancement in a hyperdense lesion may be difficult to appreciate on routine CT images and DECT iodine maps show the enhancement well even in hyperdense parts of the lesion [Figure 22].
Figure 22 (A-D)

The contrast enhanced CT shows a bilobed complex cystic lesion arising exophytically from the right kidney. The superior lobule shows thick walls with measurable enhancement (arrow) (A) while the inferior lobule shows wall calcification (short arrow) (B). The DECT iodine maps (C and D) shows definite iodine uptake in the thick walls of the superior lobule, suggestive of bosniak class 3 cystic lesion

The contrast enhanced CT shows a bilobed complex cystic lesion arising exophytically from the right kidney. The superior lobule shows thick walls with measurable enhancement (arrow) (A) while the inferior lobule shows wall calcification (short arrow) (B). The DECT iodine maps (C and D) shows definite iodine uptake in the thick walls of the superior lobule, suggestive of bosniak class 3 cystic lesion Adrenal lesions The majority of the adrenal lesions seen on an abdomen CT scan are benign. On imaging the diagnosis of a benign adrenal lesion can be confidently made if it shows a Hounsfield value (HU) value of less than 10 on an unenhanced image (adenoma), shows macroscopic fat (myelolipoma) or has attenuation of water (cyst). The appearance of an adenoma on DECT is variable and may show decrease or increase in attenuation at lower kV images than higher, depending on the amount of lipid within the lesion.[24] DECT iodine maps can help pick up enhancing focal lesions in an adrenal gland [Figure 23].
Figure 23 (A-E)

The same case of carcinoma of lung (A and B) as shown in Figure 17, also shows an enhancing nodule in the left adrenal gland (arrow) (C), worrisome for metastatic disease. The DECT iodine maps confirms the iodine uptake in the left adrenal gland nodule (E), and also shows another nodule with iodine uptake in the right adrenal gland (D) as well

The same case of carcinoma of lung (A and B) as shown in Figure 17, also shows an enhancing nodule in the left adrenal gland (arrow) (C), worrisome for metastatic disease. The DECT iodine maps confirms the iodine uptake in the left adrenal gland nodule (E), and also shows another nodule with iodine uptake in the right adrenal gland (D) as well Bowel pathologies DECT is helpful in the evaluation of inflammatory bowel pathologies and shows the inflammation/enhancement of the wall better [Figure 24]. It is also useful in assessing the severity and evaluate extraintestinal manifestations. Iodine maps demonstrate bowel wall enhancement/hyperemia in cases of inflammatory bowel disease. Coexisting neoplastic lesion can also be better assessed with DECT in such cases.
Figure 24 (A-D)

32 years male on treatment for inflammatory bowel disease presented with acute abdominal pain and diarrhoea. The contrast enhanced CT axial (A and B) and coronal (C) images shows multifocal areas of small bowel thickening (arrows) with mesenteric hypervascularity (Comb's sign) (short arrows), fat stranding and lymph nodes, suggestive of inflammatory bowel disease. The DECT iodine maps (D) shows active areas with significant iodine uptake (arrows) in the thickened bowel loops

32 years male on treatment for inflammatory bowel disease presented with acute abdominal pain and diarrhoea. The contrast enhanced CT axial (A and B) and coronal (C) images shows multifocal areas of small bowel thickening (arrows) with mesenteric hypervascularity (Comb's sign) (short arrows), fat stranding and lymph nodes, suggestive of inflammatory bowel disease. The DECT iodine maps (D) shows active areas with significant iodine uptake (arrows) in the thickened bowel loops Post ablation analysis Radiofrequency ablation (RFA) is now frequently used to treat a focal lesion in the liver, lung or kidney. It is important to detect residual tumor post RFA to decide if re-ablation is necessary. Conventionally, contrast enhanced single energy CT has been used to evaluate the success of RFA, and it may be difficult to pick up residual tumor and differentiate it from post ablation changes. DECT allows better depiction of the enhancing component in residual lesions using iodine overlay images, while the necrotic post-ablation regions appear avascular and do not show iodine uptake [Figure 25]. Monochromatic images also allow selection of the optimal keV that shows the best contrast to noise ratio between the tissues, thus allowing better evaluation of the interface between the ablation zone and surrounding tissue.[25]
Figure 25 (A-G)

Axial HRCT (A) and contrast enhanced (B) images shows an enhancing speculated mass in the left upper lobe (arrows), which on biopsy was proved to be adnocarcinoma. RFA (C) was performed to treat the lesion. The preablation DECT iodine maps (D and E) shows significant iodine uptake, which significantly reduced following RFA (F and G) suggestive of successful ablation

Axial HRCT (A) and contrast enhanced (B) images shows an enhancing speculated mass in the left upper lobe (arrows), which on biopsy was proved to be adnocarcinoma. RFA (C) was performed to treat the lesion. The preablation DECT iodine maps (D and E) shows significant iodine uptake, which significantly reduced following RFA (F and G) suggestive of successful ablation

Atomic number maps (Rho/Z)

The new dual energy CT application allows calculation of the atomic number in the lesion, for separation of various materials. Mileto et al.[26] showed that non-enhancing renal cysts, including hyperattenuating cysts, can be discriminated from enhancing masses on effective atomic number maps. They concluded 8.36 value was the optimal threshold with the enhancing masses showing higher values. Our cases also showed similar results [Figures 26 and 27].
Figure 26 (A-D)

The contrast enhanced CT (A and B) images shows 2 enhancing masses (arrows) in the right kidney. The DECT atomic number maps shows Rho/Z values of 9.11 (C) and 10.5 (D) for the two masses, confirming solid enhancing masses

Figure 27 (A and B)

The contrast enhanced CT (A) image shows a nonenhancing cystic lesion (arrow) in the left kidney. The DECT atomic number maps shows Rho/Z value of 8.27 (B), confirming non-enhancing cystic lesion

The contrast enhanced CT (A and B) images shows 2 enhancing masses (arrows) in the right kidney. The DECT atomic number maps shows Rho/Z values of 9.11 (C) and 10.5 (D) for the two masses, confirming solid enhancing masses The contrast enhanced CT (A) image shows a nonenhancing cystic lesion (arrow) in the left kidney. The DECT atomic number maps shows Rho/Z value of 8.27 (B), confirming non-enhancing cystic lesion

Conclusion

DECT is useful in clinical practice and clearly has many advantages over conventional single energy CT scanners. Various applications described in this pictorial essay highlight the growing importance of DECT. Some new applications which may be used in future are under evaluation. One such example is liver iron estimation in patients with thalassemia.[2728]

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  27 in total

1.  Dual-energy CT: clinical applications in various pulmonary diseases.

Authors:  Mi-Jin Kang; Chang Min Park; Chang-Hyun Lee; Jin Mo Goo; Hyun Ju Lee
Journal:  Radiographics       Date:  2010-05       Impact factor: 5.333

Review 2.  Shoulder arthroplasty.

Authors:  Florian M Buck; Bernhard Jost; Juerg Hodler
Journal:  Eur Radiol       Date:  2008-07-11       Impact factor: 5.315

3.  Dual-energy computed tomography for evaluation of pulmonary nodules with emphasis on metastatic lesions.

Authors:  Jens Altenbernd; Axel Wetter; Lale Umutlu; Steffen Hahn; Adrian Ringelstein; Michael Forsting; Thomas Lauenstein
Journal:  Acta Radiol       Date:  2015-04-22       Impact factor: 1.990

4.  Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies.

Authors:  J S Suh; E K Jeong; K H Shin; J H Cho; J B Na; D H Kim; C D Han
Journal:  AJR Am J Roentgenol       Date:  1998-11       Impact factor: 3.959

5.  Dual-energy CT for characterization of adrenal nodules: initial experience.

Authors:  Rajan T Gupta; Lisa M Ho; Daniele Marin; Daniel T Boll; Huiman X Barnhart; Rendon C Nelson
Journal:  AJR Am J Roentgenol       Date:  2010-06       Impact factor: 3.959

6.  Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study.

Authors:  Gregor Pache; Bernhard Krauss; Peter Strohm; Ulrich Saueressig; Philipp Blanke; Stefan Bulla; Oliver Schäfer; Peter Helwig; Elmar Kotter; Mathias Langer; Tobias Baumann
Journal:  Radiology       Date:  2010-06-15       Impact factor: 11.105

7.  Dual-Energy CT for Patients Suspected of Having Liver Iron Overload: Can Virtual Iron Content Imaging Accurately Quantify Liver Iron Content?

Authors:  Xian Fu Luo; Xue Qian Xie; Shu Cheng; Yi Yang; Jing Yan; Huan Zhang; Wei Min Chai; Bernhard Schmidt; Fu Hua Yan
Journal:  Radiology       Date:  2015-04-16       Impact factor: 11.105

8.  Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results.

Authors:  C Fink; T R Johnson; H J Michaely; D Morhard; C Becker; M Reiser; K Nikolaou
Journal:  Rofo       Date:  2008-10

9.  The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography.

Authors:  Wieland H Sommer; Thorsten R Johnson; Christoph R Becker; Elisabeth Arnoldi; Harald Kramer; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Invest Radiol       Date:  2009-05       Impact factor: 6.016

10.  Dual-energy CT after radiofrequency ablation of liver, kidney, and lung lesions: a review of features.

Authors:  Frederik Vandenbroucke; Steven Van Hedent; Gert Van Gompel; Nico Buls; Gordon Craggs; Jef Vandemeulebroucke; Pablo R Ros; Johan de Mey
Journal:  Insights Imaging       Date:  2015-05-05
View more
  4 in total

Review 1.  Dual energy CT in musculoskeletal applications beyond crystal imaging: bone marrow maps and metal artifact reduction.

Authors:  Gaurav Cheraya; Salil Sharma; Avneesh Chhabra
Journal:  Skeletal Radiol       Date:  2022-02-02       Impact factor: 2.199

2.  Influence of Radiation Dose and Reconstruction Kernel on Fat Fraction Analysis in Dual-energy CT: A Phantom Study.

Authors:  Vasiliki Chatzaraki; Corinna Born; Rahel A Kubik-Huch; Johannes M Froehlich; Michael J Thali; Tilo Niemann
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

3.  A novel parameter derived from post-processing procedure of dual energy CT for identification of gout.

Authors:  Chunlin Xiang; Hongyan Zhang; Gang Wu
Journal:  Sci Rep       Date:  2021-11-03       Impact factor: 4.379

4.  Effect of abdominal adipose content on spine phantom bone mineral density measured by rapid kilovoltage-switching dual-energy CT and quantitative CT.

Authors:  Hang Ye; Xiaoyang Li; Ning Yao; Yuting Shi; Yujiao Wang; Wanjiang Yu
Journal:  Quant Imaging Med Surg       Date:  2022-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.