Literature DB >> 26928067

Dual-Energy CT-based Display of Bone Marrow Edema in Osteoporotic Vertebral Compression Fractures: Impact on Diagnostic Accuracy of Radiologists with Varying Levels of Experience in Correlation to MR Imaging.

Moritz Kaup1, Julian L Wichmann1, Jan-Erik Scholtz1, Martin Beeres1, Wolfgang Kromen1, Moritz H Albrecht1, Thomas Lehnert1, Marie Boettcher1, Thomas J Vogl1, Ralf W Bauer1.   

Abstract

Purpose To evaluate whether a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique can improve the detection rate of acute thoracolumbar vertebral compression fractures in patients with osteoporosis compared with that at magnetic resonance (MR) imaging depending on the level of experience of the reading radiologist. Materials and Methods This retrospective study was approved by the institutional ethics committee. Informed consent was obtained from all patients. Forty-nine patients with osteoporosis who were suspected of having acute vertebral fracture underwent DE CT and MR imaging. Conventional linear-blended CT scans and corresponding virtual noncalcium reconstructions were obtained. Five radiologists with varying levels of experience evaluated gray-scale CT scans for the presence of fractures and their suspected age. Then, virtual noncalcium images were evaluated to detect bone marrow edema. Findings were compared with those from MR imaging (the standard of reference). Sensitivity and specificity analyses for diagnostic performance and matched pair analyses were performed on vertebral fracture and patient levels. Results Sixty-two fractures were classified as fresh and 52 as old at MR imaging. The diagnostic performance of all readers in the detection of fresh fractures improved with the addition of virtual noncalcium reconstructions compared with that with conventional CT alone. Although the diagnostic accuracy of the least experienced reader with virtual noncalcium CT (accuracy with CT alone, 61%; accuracy with virtual noncalcium technique, 83%) was within the range of that of the most experienced reader with CT alone, the latter improved his accuracy with the noncalcium technique (from 81% to 95%), coming close to that with MR imaging. The number of vertebrae rated as unclear decreased by 59%-90% or from 15-53 to 2-13 in absolute numbers across readers. The number of patients potentially referred to MR imaging decreased by 36%-87% (from 11-23 to 2-10 patients). Considering the gain in true decisions with the virtual noncalcium technique on a patient level, between 12 (most experienced reader) and 17 (least experienced reader) MR examinations could have been avoided. Conclusion The DE CT-based virtual noncalcium technique may enable depiction of bone marrow edema in thoracolumbar vertebral compression fractures in patients with osteoporosis, with good accordance with MR imaging when images are read by experienced radiologists. Although less experienced readers improved their diagnostic performance to some degree, the experienced reader's diagnostic performance approached that with MR imaging. (©) RSNA, 2016.

Entities:  

Mesh:

Year:  2016        PMID: 26928067     DOI: 10.1148/radiol.2016150472

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  33 in total

1.  Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI.

Authors:  Giovanni Foti; Matteo Catania; Simone Caia; Luigi Romano; Alberto Beltramello; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2019-07-04       Impact factor: 3.469

Review 2.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

Review 3.  Conservative management of osteoporotic vertebral fractures: an update.

Authors:  A Slavici; M Rauschmann; C Fleege
Journal:  Eur J Trauma Emerg Surg       Date:  2016-12-26       Impact factor: 3.693

4.  Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures.

Authors:  Giovanni Foti; Alberto Beltramello; Matteo Catania; Stefano Rigotti; Gerardo Serra; Giovanni Carbognin
Journal:  Radiol Med       Date:  2019-02-02       Impact factor: 3.469

5.  Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study.

Authors:  Torsten Diekhoff; Nils Engelhard; Michael Fuchs; Matthias Pumberger; Michael Putzier; Jürgen Mews; Marcus Makowski; Bernd Hamm; Kay-Geert A Hermann
Journal:  Eur Radiol       Date:  2018-06-15       Impact factor: 5.315

Review 6.  Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis.

Authors:  Chong Hyun Suh; Seong Jong Yun; Wook Jin; Sun Hwa Lee; So Young Park; Chang-Woo Ryu
Journal:  Eur Radiol       Date:  2018-04-20       Impact factor: 5.315

7.  Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study.

Authors:  Christian Booz; Jochen Nöske; Lukas Lenga; Simon S Martin; Ibrahim Yel; Katrin Eichler; Tatjana Gruber-Rouh; Nicole Huizinga; Moritz H Albrecht; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2019-07-26       Impact factor: 5.315

8.  Combined radiomics-clinical model to predict malignancy of vertebral compression fractures on CT.

Authors:  Choong Guen Chee; Min A Yoon; Kyung Won Kim; Yusun Ko; Su Jung Ham; Young Chul Cho; Bumwoo Park; Hye Won Chung
Journal:  Eur Radiol       Date:  2021-03-19       Impact factor: 5.315

9.  Bone Subtraction Iodine Imaging Using Area Detector CT for Evaluation of Skull Base Invasion by Nasopharyngeal Carcinoma.

Authors:  T Hiyama; H Kuno; K Sekiya; S Tsushima; O Sakai; M Kusumoto; T Kobayashi
Journal:  AJNR Am J Neuroradiol       Date:  2018-12-06       Impact factor: 3.825

Review 10.  The application of dual-energy computed tomography in the diagnosis of musculoskeletal disorders: a review of current concepts and applications.

Authors:  Marina Carotti; Fausto Salaffi; Giacomo Beci; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-03-04       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.