Wearable systems for shoulder kinematics assessment: a systematic review.

Arianna Carnevale1, Umile Giuseppe Longo2, Emiliano Schena3, Carlo Massaroni3, Daniela Lo Presti3, Alessandra Berton1, Vincenzo Candela1, Vincenzo Denaro1.   

Abstract

BACKGROUND: Wearable sensors are acquiring more and more influence in diagnostic and rehabilitation field to assess motor abilities of people with neurological or musculoskeletal impairments. The aim of this systematic literature review is to analyze the wearable systems for monitoring shoulder kinematics and their applicability in clinical settings and rehabilitation.
METHODS: A comprehensive search of PubMed, Medline, Google Scholar and IEEE Xplore was performed and results were included up to July 2019. All studies concerning wearable sensors to assess shoulder kinematics were retrieved.
RESULTS: Seventy-three studies were included because they have fulfilled the inclusion criteria. The results showed that magneto and/or inertial sensors are the most used. Wearable sensors measuring upper limb and/or shoulder kinematics have been proposed to be applied in patients with different pathological conditions such as stroke, multiple sclerosis, osteoarthritis, rotator cuff tear. Sensors placement and method of attachment were broadly heterogeneous among the examined studies.
CONCLUSIONS: Wearable systems are a promising solution to provide quantitative and meaningful clinical information about progress in a rehabilitation pathway and to extrapolate meaningful parameters in the diagnosis of shoulder pathologies. There is a strong need for development of this novel technologies which undeniably serves in shoulder evaluation and therapy.

Entities:  

Keywords:  Inertial sensors; Shoulder kinematics; Smart textile; Upper limb; Wearable system

Mesh:

Substances:

Year:  2019        PMID: 31731893      PMCID: PMC6858749          DOI: 10.1186/s12891-019-2930-4

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


Background

Shoulder kinematics analysis is a booming research field due to the emergent need to improve diagnosis and rehabilitation procedures [1]. The shoulder complex is the human joint characterized by the greatest range of motion (ROM) in the different planes of space. Commonly, several scales and tests are used to evaluate shoulder function, e.g., the Constant-Murley score (CMS), the Simple Shoulder test (SST), the Visual Analogue Scale (VAS) and the Disability of the Arm, Shoulder, and Hand (DASH) score [2-4]. However, despite their easy-to-use and wide application in clinical settings, these scores conceal an intrinsic subjectivity [2-4], inaccuracy in approaching diagnosis, follow-up and treatment of the pathologies. Quantitative and objective analyses are rapidly developing as a valid alternative to evaluate shoulder activity level, to gauge its functioning and to provide information about movement quality, e.g., velocity, amplitude and frequency [5, 6]. This interest in the use of measuring systems is growing in many medical fields to record information of clinical relevance. For example, electromyography (EMG), force sensors, inertial measurement units (IMU), accelerometers, fiber optic sensors and strain sensors are employed for human motion analysis, posture and physiological parameters monitoring [7-10]. From a technological viewpoint, the monitoring of shoulder motion is challenging due to the complexity of joint kinematic which require the development of protocols exploiting sensing technology as much as possible reliable and unobtrusive. In the last years, a great number of human motion analysis systems have been largely employed for objective monitoring. These systems can be classified into two main categories: wearable and non-wearable [11]. The last one includes electromagnetic tracking systems (e.g., Fastrak) [12], ultrasound-based motion analysis systems (e.g., Zebris) [13], stereo-photogrammetric and optoelectronic systems (e.g., VICON, Optotrak, BTS SMART-D) often used as gold standard [14-17]. These systems based on magnetic field, ultrasound and cameras are effectively suitable for 3D motion tracking and analysis due to their accuracy, precision and reliability [18]. On the other hand, such systems require expensive equipment, frequent calibration and, overall, they restrict measurements in structured environment [19]. Wearable systems overcome these shortcomings and they are a promising solution for continuous and long-term monitoring of human motion in daily living activities. Gathering data in unstructured environment continuously (e.g., home environment) provide additional information compared to those obtainable inside a laboratory [20]. Wearable sensor-based systems, intended for kinematics data extraction and analyses, are acquiring more and more influence in diagnostic applications, rehabilitation follow-up, and treatments of neurological and musculoskeletal disorders [21, 22]. Such systems comprise accelerometers, gyroscopes, IMU, among others [23]. Patients’ acceptance of monitoring systems that should be worn for long-time relies on sensors’ features whose must be lightweight, unobtrusive and user-friendly [24]. The increasing trend to adopt such wearable systems has been promoted by the innovative technology of micro-electro-mechanical systems (MEMS). MEMS technology has fostered sensors’ miniaturization, paving the way for a revolutionary technology suited to a wide range of applications, including extraction of clinical-relevant kinematics parameters. In recent years, there has been growth in the use of smart textile-based systems which integrate sensing units directly into garments [11, 25, 26]. Moreover, in the era of big data, machine learning technical analysis can improve home rehabilitation thanks to the recognition of the quality level of performed physical exercises and the possibility to prevent disorders in patients’ movement [27]. The aim of this systematic literature review is to describe the wearable systems for monitoring shoulder kinematics. The authors want to summarize the main features of the current wearable systems and their applicability in clinical settings and rehabilitation for shoulder kinematics assessment.

Methods

Literature search strategy and study selection process

A systematic review was executed applying the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines [28]. Full-text articles and conference proceedings were selected from a comprehensive search of PubMed, Medline, Google Scholar and IEEE Xplore databases. The search strategy included free text terms and Mesh (Medical Subject Headings) terms, where suited. These terms were combined using logical Boolean operators. Keywords and their synonyms were combined in each database as follows: (“shoulder biomechanics” OR “upper extremit*” OR “shoulder joint” OR “scapular-humeral” OR “shoulder kinematics” OR “upper limb”) AND (“wearable system*” OR “wearable device*” OR “wearable technolog*” OR “wearable electronic device*” OR “wireless sensor*” OR “sensor system” OR “textile” OR “electronic skin” OR “inertial sensor”). No filter was applied on the publication date of the articles, and all results of each database were included up to July 2019. After removal of duplicates, all articles were evaluated through a screening of title and abstract by three independent reviewers. The same three reviewers performed an accurate reading of all full-text articles assessed for eligibility to this study and they performed a collection of data to minimize the risk of bias. In case of disagreement among investigators regarding the inclusion and exclusion criteria, the senior investigator made the final decision. Inclusion criteria were: The studies concern wearable systems as a tool to assess upper limb kinematics; The studies used sensors directly stuck on the human skin by means of adhesive, embedded within pockets, straps or integrated into fabrics; Systems intended for motion recognition and rehabilitation; Articles are written in English language; Papers are published in a peer-reviewed journal or presented in a conference; Exclusion criteria were: Use of prosthetics, exoskeleton or robotic systems; Wearable system not directly worn or tested on human; The study concerns wearable systems for full-body motion tracking; Shoulder joint is not included; Reviews, books.

Data extraction process

Data extraction was executed on 73 articles. Data was extracted on the base of the following checklist: authors, year and type of publication (i.e., conference or full-text); typology, number, brand and placement of the sensors used to measure or track the kinematic of the interested joint, wearability of the system, target parameters with regard to the shoulder; system used as gold standard to assess the wearable systems’ performance; tasks executed in the assessment protocol; characteristics of the participants involved in the study and aim of the study.

Results

The literature search returned 1811 results and additional 14 studies were identified through other sources. A total of 73 studies fulfilled the inclusion criteria (Fig. 1), of which 27% were published on conference proceedings and the remaining 73% on peer-reviewed journal.
Fig. 1

PRISMA 2009 flow diagram

PRISMA 2009 flow diagram Three levels of analysis have been emphasized in this survey: A. application field and main aspects covered, B. the typology of sensors exploited to measure kinematic parameters, C. the placement of the single measurement units on the body segment of interest and how sensing modules are integrated into the wearable system from a wearability viewpoint.

Application field

Fifteen out of the 73 studies focused on evaluating upper limbs motion in case of musculoskeletal diseases (e.g., osteoarthritis, rotator cuff tear, frozen shoulder), 26 on neurological diseases and ap-plication in neurorehabilitation (e.g., stroke, multiple sclerosis), 15 on general rehabilitation aspects (e.g., home rehabilitation, physiotherapy monitoring) and 17 focusing on validation and development of systems and algorithm for monitoring shoulder kinematics. Tables 1, 2, 3 and 4 include, for each of the identified application fields, data listed in the previous data extraction process section.
Table 1

Shoulder motion monitoring for application in patients with musculoskeletal disorders

Reference, Year, Type of publicationSensors, BrandPlacement and wearabilityTarget shoulder parameters, PerformanceGold standardTask executedParticipantsAim

Coley 2007, [29]

Full-Text

IMU (n = 2),

Analog Device

(gyr: ADXRS 250, acc: ADXL 21 0)

Bilateral:

humeri (posteriorly, distally)

Adhesive patch

Sh ROM

(HT joint angles), RMSE =5.81°

Mean = 1.80°

Zebris

CMS-HS

Sh FLX-EXT

Sh AB-AD

Sh IER

HS (n = 10),

25.1 ± 4.1 Y

P (n = 10),

7 RC, 3 OA,

4 F, 6 M,

62.4 ± 10.4 Y

Find objective scores to assess shoulder function; to validate such scores comparing healthy and affected shoulders

Coley 2008, [30]

Full-Text

IMU (n = 4),

Analog Device

(gyr: ADXRS 250,

acc: ADXL 21 0)

Bilateral:

humeri (posteriorly, distally), thorax

Adhesive patch

Sh ROM

(HT joint angles)

Daily activities (8 h)

HS (n = 35)

32 ± 8 Y

Quantify usage of shoulder and the contribution of each shoulder in daily life activities

Jolles 2011, [31]

Full.Text

IMU (n = 4),

Analog Device (gyr: ADXRS 250, acc: ADXL 21 0)

Bilateral:

Humeri (distally, posteriorly), thorax (× 2)

Adhesive patch

Sh ROM

(HT joint angles), r = 0.61–0.80

7 activities of SST

P (n = 34)

27 RC, 7 OA

25 M, 9 F

57.5 ± 9.9

CG (n = 31)

17 M, 14 F

33.3 ± 8.0

Validate clinically shoulder parameters in patients after surgery for GH OA and RC disease

Duc 2013, [5]

Full-Text

IMU (n = 3),

Analog Device (gyr: ADXRS 250, acc: ADXL 210)

Bilateral:

Humeri (distal, posterior), sternum

Adhesive patch

Sh ROM

(HT joint angles), r2 = 0.13-0.52 (CMS)

r2 = 0.06-0.30 (DASH)

r2 = 0.03-0.31 (SST)

Free movements, daily activities

HS (n = 41)

34 ± 9 Y

P (n = 21)

53 ± 9 Y

RC (unilateral)

Validate a method to detect movement of the humerus relative to the trunk and to provide outcomes parameters after shoulder surgery (frequency of arm movement and velocity)

Körver 2014, [32]

Full-Text

IMU (n = 2),

Inertia-Link-2400-SKI, MicroStrain

Bilateral:

Humerus (distal, posterior)

Adhesive

Sh ROM

(HT joint angles),

r = 0.39 (DASH)

r = 0.32 (SST)

Hand to the back,

Hand behind the head

HS (n = 100)

37 M, 63 F

40.6 ± 15.7 Y

P (n = 15)

5 M, 10 F

57.7 ± 10.4 Y, Subacromial impingement

Investigate about the correlation between subjective (clinical scale) and objective (IMU) assessment of shoulder ROM during a long-term period of follow-up

Van Den Noort 2014, [33]

Full-Text

M-IMU (n = 4),

Xsens MTw

Unilateral:

Thorax, scapula,

UA, FA

Straps, skin tape

Sh ROM

(HT and ST joint angles)

FLX (sagittal plane) and AB (frontal plane) with elb extended and thumb pointing up

HS (n = 20)

3 M, 17 F

36 ± 11 Y

Evaluate the intra- and inter-observer reliability and precision of 3D scapula kinematics

Pichonnaz 2015, [34]

Full-Text

IMU (n = 3),

Analog Device

(acc: ADXL 210,

gyr: ADXRS 250)

Bilateral:

Sternum, Humeri (posterior, distal)

Skin tape

Sh ROM

(HT joint angles)

Free movements

(7 h)

HS (n = 41)

23 M, 18 F

34.1 ± 8.8 Y

P (n = 21)

14 M, 7 F

53.3 ± 9 Y

RC

Explore dominant and non-dominant arm usage as an indicator of UL function after rotator cuff repair during the first year after surgery

Roldán-Jiménez e Cuesta-Vargas 2015, [35]

Full-Text

M-IMU (n = 4),

InterSense InertiaCube3

Unilateral:

Sternum, humerus,

scapula, FA (near wrist)

adhesive tape and bandage

Sh ROM

(HT and ST joint angles)

180° sh AB and EXT with wri in neutral position and elb extended

HS (n = 11)

8 M, 3 F

24.7 ± 4.2 Y

Analyse UL angular mobility and linear acceleration in three anatomical axes

Van Den Noort 2015, [36]

Full-Text

M-IMU (n = 4),

Xsens MTw

Unilateral:

Thorax, Scapula, UA, FA

(ISEO protocol [33, 37])

Straps, skin tape

Sh ROM

(ST joint angles)

Humeral FLX (sagittal plane) and AB (frontal plane) with elb extended and thumb pointing up

P (n = 10)

8 M, 2 F

24–63 Y

SD

Evaluate the change in 3D scapular kinematics using a single and double anatomical calibration with a scapular locator versus standard calibration; evaluate difference in 3D scapular kinematics between static posture and dynamic humeral elevation

Roldán-Jiménez e Cuesta-Vargas 2016, [38]

Full-Text

M-IMU (n = 3), InterSense, InertiaCube3

Unilateral:

Humerus (middle third, slightly posterior), scapula, sternum

Double-sided tape, elastic bandage

Sh ROM

(GH and ST joint angles)

Sh AB (frontal plane)

Sh FLX (sagittal plane)

Wri in neutral position and elb extended

Young HS (n = 11),

18–35 Y

3 M, 8 F

Adult HS (n = 14)

> 40 Y

5 M, 9F

Analyze differences in shoulder kinematics in terms of angular mobility and linear acceleration related to age

Wang 2017, [26]

Full-Text

M-IMU (n = 3), Adafruit FLORA 9-DOF

Unilateral:

Shoulder (flat part of acromion), spine (C7-T1, T4-T5)

Zipped vest, elastic strap with Velcro

Sh ROM

(ST joint angles), RMSE ~ 3.57°

PST-55/110 series60 ° sh FLX with elb extended and thumb pointing up, place a cooking pot on a shelf, 40 ° sh EL in the scapular plane with elb extended and thumb pointing up, place a bottle of water on a shelf

P with musculoskeletal shoulder pain (n = 8)

3 M, 5 F

50 ± 6.44Y

Physiotherapist (n = 5)

Evaluate usability of a smart garment-supported postural feedback scapular training in patients with musculoskeletal shoulder pain and in physiotherapists who take care patients with shoulder disorders

Aslani 2018, [39]

Full-Text

M-IMU (n = 1), Bosh Sensortec BNO055

EMG, MyoWare Muscle Sensor

Unilateral:

UA, deltoid (2 surface electrodes on each deltoid section)

Band

Sh ROM (azimuthal and elevation angles)Arm EL (medially, anteriorly, cranially, posteriorly, laterally) with elb fully extended

HS (n = 6)

4 M, 2 F

27.3 ± 3.4Y

P (n = 1), M

Frozen Sh

42 Y

Evaluate a measurements protocol to assess the performance of the shoulder by combining both ROM and electromyography measurements

Carbonaro 2018, [40]

Conference

M-IMU (n = 3), Xsens MTw

Unilateral:

Sternum, FA (distal), scapula (similar to the configuration in [37])

Elastic bands

Sh ROM

(GH and ST joint angles)

Extra-rotation,

Arm AB (with different load)

HS (n = 5)Test a digital application intended for tele-monitoring and tele-rehabilitation of the shoulder muscular-skeletal diseases

Hurd 2018, [41]

Full-Text

Acc buil.in ActiGraph

(n = 2), ActiGraph GT3XP-BLE

Unilateral:

Wrist, UA (mid-biceps level)

Velcro strap

Sh ROMADL

P (n = 14)

7 M, 7 F

73 ± 6Y

GH OA, RC disease

Evaluate changes in pain, self-reported function and objective measurement of upper limb activity after RSA

Langohr 2018, [6]

Full-Text

IMU (n = 5), YEI Technology

Bilateral:

Sternum, UA (lateral aspects of the midhumerus), FA (dorsal aspect of the wrist)

Shirt

Sh ROM (humeral elevation and plane of elevation angles)

Daily activities

(1 day, monitoring of 11 ± 3 h)

P (n = 36)

73 ± 10 Y

TSA, RTSA

Determine the total daily shoulder motion of patients after TSA and RTSA, compare the motion of the arthroplasty shoulder with that of the contralateral asymptomatic joint and compare the daily motion of TSA and RTSA shoulders

acc accelerometer, gyr gyroscope, magn magnetometer, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, ST scapulothoracic, GH glenohumeral, Sh shoulder, wri wrist, elb elbow, FLX-EXT flexion-extension, AB-AD abduction-adduction, IER internal-external rotation, RMSE root mean square error, r = correlation, r2, coefficient of determination, HS Healthy subject, CG Control Group, P patient, M male, F female, RC Rotator Cuff, OA Osteoarthritis, Y Years old, SST Simple Shoulder test, DASH Disability of the Arm, Shoulder and Hand, CMS Constant Murley Score

Table 2

Shoulder motion monitoring for application in patients with neurological disorders

Reference, Year, Type of publicationSensors, BrandPlacement and wearabilityTarget shoulder parameters, PerformanceGold standardTask executedParticipantsAim

Bartalesi 2005, [8]

Conference

Strain sensor, WACKER Ltd.

(ELASTOSIL LR 3162 A/B)

Unilateral:

Sensors’ segment series along right upper limb

Shirt

Sh ROMHSWearable garment able to reconstruct shoulder, wrist and elbow movement to correct stroke patients’ rehabilitation exercises

Hester 2006, [42]

Conference

Acc (n = 6)

Unilateral:

thumb, index, back of the hand, FA and UA (medially), thorax

Adhesive

Sh ROMReaching, prehension, manipulationSP (n = 12)Predict clinical scores of stroke patients’ motor abilities

Zhou 2006, [43]

Full-Text

IMU (n = 2),

Xsens MT9B

Unilateral:

Wrist (inwards), elbow (outwards)

-

Sh orientation and position

FA FLX-EXT

FA PR-SU, reach test

HS (n = 1, M)Propose a data fusion algorithm to locate the shoulder joint without drift

Willmann 2007, [44]

Conference

M-IMU (n = 4),

Philips

Unilateral:

Torso, shoulder, UA, FA

Garment

Sh ROMHSProvide a home system for upper limb rehabilitation in stroke patients

Zhou 2008, [45]

Full-Text

M-IMU (n = 2),

Xsens MT9B

Unilateral:

FA (distally, near the wrist center), UA (laterally, on the line between the lateral epicondyle and the acromion process)

Velcro straps

Sh orientation and position,

RMSE = 2.5°-4.8°

CODA

reaching

shrugging

FA rotation

HS (n = 4, M)

20–40 Y

Validate data fusion algorithm

Giorgino 2009, [46]

Full-Text

Strain sensor (n = 19),

WACKER Ltd.

(ELASTOSIL LR 3162 A/B)

Unilateral:

Sensors’ sensing segments distributed over the UA, FA, shoulder, elbow, wrist

Shirt

Sh ROM

GH FLX (sagittal plane)

Lateral AB

ER

HS (n = 1)Describe a sensing garment for posture recognition in neurological rehabilitation

Lee 2010, [47]

Full-Text

Acc (n = 2),

Freescale MMA7261 QT

Unilateral:

UA, FA

Velcro strap

Sh ROM,

Mean error~0°-3.5°

gonFLX-EXT (sagittal plane)HS (n = 1)Validate performance and accuracy of the system

Chee Kian 2010, [48]

Conference

OLE (n = 1)

Acc (n = 1)

Unilateral:

UA, elbow

Adhesive patch

Sh ROMIGS-190Cyclic movements with arm exerciserHS (n = 1)Validate feasibility and performance (accuracy, repeatability) of the proposed sensing system designed to assist stroke patients in upper limb home rehabilitation

Patel 2010, [49]

Full-Text

Acc (n = 6)

Unilateral:

thumb, index, back of the hand, FA, UA, trunk

-

Sh ROM8 activities of FAS

SP (n = 24)

57.5 ± 11.8 Y

Evaluate accuracy of FAS score obtained via analysis of the accelerometers data comparing such estimates with scores provided by an expert clinician using this scale

Pérez 2010, [15]

Full-Text

M-IMU (n = 4),

Xsens MTi

Unilateral:

UA (18 cm from acromion), FA (25 cm from epicondyle), hand (5.5 cm from distal radio-cubital joint), back (position is not relevant)

Strap

Sh ROM,

r = 0.997 (for sh IR, after calibration)

BTS SMART-D

Sh FLX-EXT

Sh horizontal AB-AD

Sh IR

Elb FLX

Elb PR-SU

Wri FLX-EXT

Serving water from a jar

HS (n = 1, F)Validate the system

Bento 2011, [50]

Conference

M-IMU (n = 4)

Bilateral:

Shoulder, UA, wrist (affected and unaffected side)

Strap

Sh orientation and position

FA to Table

FA to box

Extend elbow

Hand to table

Hand to box

SP (n = 5, M)

35–73 Y

Preliminary validation of a system able to quantify upper limb motor function in patients after neurological trauma

Nguyen 2011, [51]

Full-Text

OLE (n = 3)

Acc (n = 3)

Unilateral:

Shoulder, elbow, wrist

Clothing module fixed with Velcro straps

Sh ROM,

Test2: RMSE = 3.8° (gon), RMSE = 3.1° (SW)

Test3: ICC = 0.975 (sh)

Test2: gon, Shape-

Wrap

Test2: Bend and

Flex elbow

Test3: reaching task

Test2:

HS (n = 3, M);

Test3:

HS (n = 5)

Validation of the proposed motion capture system

Ding 2013, [52]

Full-Text

M-IMU (n = 2),

Analog Device (acc: ADXL320), HoneyWell (magn: HMC1 053), Silicon Sensing System (gyr)

Unilateral:

UA (distal, near elbow), FA (distal, near wrist)

Velcro strap

Sh ROMReplication of 10 reference arm posture

HS (n = 5)

20–27 Y

Check the feasibility of the proposed system which measures orientation and corrects upper limb posture using vibrotactile actuators

Lee 2014, [53]

Full-Text

M-IMU (n = 7),

Analog Device (acc:ADXL 345)

InvenSense

(gyr: ITG3200)

Honeywell

(magn: HMC5883L)

Bilateral:

Back, UA, FA and hand

Strap

Sh ROM,

Test1: r = 0.963

Test2: RMSE< 5°

Test1:

gon

Test2: VICON

Sh FLX-EXT

Sh AB

Arm IER

Elb FLX

FA PR-SU

Wri FLX-EXT

Wri radial-ulnar deviation

SP (n = 5)

2 M, 3 F

Mean age: 68 Y

Introduce a smartphone centric wireless wearable system able to automate joint ROM measurements and detect the type of activities in stroke patients

Bai 2015, [54]

Full-Text

M-IMU (n = 4 or n = 1),

Xsens MTx

Unilateral

Scapula, UA, FA, back of the hand or only on UA

Velfoam, Velcro straps

Sh ROM

(upper limb segments orientation and position)

Test1:

gon

Test2:

gon, VICON

Sh FLX-EXT

Sh IER

Sh AB-AD

Elb FLX-EXT

FA PR-SU

Wri FLX-EXT

Wri radial-ulnar deviation

HS (n = 10)

8 M, 2 F

20–38 Y

P (n = 1), F

41 Y

Evaluate a four-sensor system and a one-sensor system, investigate whether these systems are able to obtain quantitative motion information from patients’ assessment during neurorehabilitation

Ertzgaard 2016, [55]

Full-Text

IMU (n = 5),

Analog Device, Adis 16,350

Bilateral:

Back (upper body), UA and FA

Strap

Sh ROM

(HT joint angles),

ICC = 0.768–0.985

CodaMovements that mimic activities of daily life

HS (n = 10)

2 M, 8 F

34.3 ± 13.1Y

SP (n = 1), F, 43 Y

Validation study to characterize elbow and shoulder motion during functional task using a modified Exposure Variation Analysis (EVA)

Lorussi 2016, [56]

Full-Text

M-IMU (n = 2),

Xsens MTw

Strain sensor (n = 1),

Smartex

Unilateral:

M-IMU sensors on sternum and UA

Textile-based strain sensor on the back (from the spine to scapula)

Shirt

Sh ROM

(HT joint angle and scapular translation)

BTS SMART-DX

UA FLX (sagittal plane)

UA AB (frontal plane)

HS (n = 5)Validate sensors and data fusion algorithm to reconstruct scapular-humeral rhythm

Mazamenos 2016, [57]

Full-Text

M-IMU (n = 2),

Shimmer2r

Unilateral:

UA (distal, near elbow), FA (distal, near wrist)

Straps

Sh ROM (segments’ orientation and position)

EXP1: Reach and retrieve, lift object to mouth, rotate an object

EXP2: preparing a cup of tea

HS (n = 18)

M, F

25–50 Y

SP (n = 4)

M, F

45–73 Y

Evaluate the performance and robustness of a detection and discrimination algorithm of arm movements

Jiang 2017, [58]

Conference

Acc (n = 4), Analog Device ADXL362

EMG (n = 4), Analog Device AD8232

Temperature (n = 1)

Unilateral:

along upper limb

Shirt

Sh ROM4 typical joint actions performed in clinical assessmentHS (n = 1), MIntroduce an IoT-Bases upper limb rehabilitation assessment system for stroke patients

Li 2017, [59]

Full-Text

IMU (n = 2), InvenSense, MPU-9250

EMG (n = 10), American Imex, Dermatrode

Unilateral:

IMU: UA, wrist

EMG: FA (n = 8), UA (n = 2)

Stretchable belt

Sh ROM

11 tasks including:

Sh FLX, Sh AB

Wri FLX-EXT,

Fetch and hold a ball or a cylindric roll, finger to nose, touch the back of the sh, FA PR-SU

HS (n = 16)

10 M, 6 F

36.25 ± 15.19Y

SP (n = 18)

11 M, 7 F

55.28 ± 12.25 Y

Propose data fusion from IMU and surface EMG for quantitative motor function evaluation in stroke subjects

Newman 2017, [60]

Full-Text

IMU (n = 3), Gait Up SA Physilog4

Bilateral:

sternum, UA (posterior)

Velcro straps, adhesive patch

Sh ROM

(HT joint angles)

Reaching movements (lateral, forward, upward)

Children (n = 30)

10.6 ± 3.4 Y

17 boys, 13 girls

Test an IMU-based system to measure upper limb function in children with hemiparesis and its correlation with clinical scores

Yang e Tan 2017, [61]

Conference

M-IMU (n = 4), APDM Opal

Unilateral:

Waist, thorax, UA (distal, near elbow), FA (distal, near elbow)

Straps

Sh ROM

(HT joint angles)

OptitrackMovements related with waist joint, sh joint and elb joints to achieve joint rotationHS (n = 2)Validate the proposed motion tracking system

Daunoraviciene 2018, [62]

Full-Text

M-IMU (n = 6), Shimmer

Bilateral:

UA, FA, hand (on centres of mass)

Strap

Sh ROMFNT test (Sh EXT, sh AB, elb FLX, hand SU)

CG (n = 24)

7 M 31.14 ± 5.67

17 F

28 ± 3.97

MS-P (n = 34)

13 M

36.46 ± 13.07

21 F

42.19 ± 12.55

Test a M-IMU based system to identify quantitative parameters for evaluation of UL disability and relate it to clinical scores

Jung 2018, [63]

Conference

M-IMU (n = 5), Xsens MTw Awinda

Bilateral:

UA and FA, trunk

Velcro straps

Sh ROM

(HT join angles), RMSE = 0.32 for the estimation of movements qualities using data of the entire duration of movements

Quality of movements’ label provided by the therapistReaching exercise

SP (n = 5), F

66.6 ± 15.9 Y

Evaluate movements quality regarding compensation and inter-joint coordination; exploiting a supervised machine learning approach, validate the hypothesis that therapists’ evaluation can be made considering only the beginning movement data

Lin 2018, [64]

Full-Text

IMU (n = 2)

Unilateral:

UA (distal, near elbow), FA (dorsal aspect of the wrist)

Strap

Sh ROM

Sh FLX-EXT

Sh AB

Sh ER

Elb FLX

FA PR-SU

SP (n = 18):

n = 9, control group (62.6 ± 7.1)

n = 9, device group (52.2 ± 10.2 Y)

Evaluate the feasibility and efficacy of an IMU-based system for upper limb rehabilitation in stroke patients and compare the intervention effects with those in a control group

Repnik 2018, [7]

Full-Text

M-IMU (n = 7),

Myo armband, n = 2_ with n = 8 EMGs built-in, Thalamic labs

Bilateral:

-M-IMU: Back of the hand, wrist, UA (distal, near elbow), sternum

-MYO: FA (in the proximity of elbow joint)

Straps, armband

Sh ROM

(HT joint angles)

ARAT tasks: 19 movements divided in 4 subtests (grasp, grip, pinch, gross arm movement)

SP (n = 28)

18 M, 10 F

57 ± 9.1 Y

HS (n = 12)

9 M, 3 F

36 ± 8 Y

Quantify UL and trunk movement in stroke patients

acc accelerometer, gyr gyroscope, magn magnetometer, OLE Optical Linear Encoder, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, GH glenohumeral, Sh shoulder, wri wrist, elb elbow, FLX-EXT flexion-extension, PR-SU pronation-supination, AB-AD abduction-adduction, IER internal-external rotation, RMSE root mean square error, r = correlation, ICC Intraclass Correlation Coefficients, gon goniometer, HS Healthy subject, CG control group, SP Stroke Patient, MS-P Multiple Sclerosis Patient, P patient, M male, F female, Y Years old, FAS Functional Ability Scale, ARAT Action research arm test

Table 3

Shoulder motion monitoring for application in patients undergoing rehabilitation

Reference, Year, Type of publicationSensors, BrandPlacement and wearabilityTarget shoulder parameters, PerformanceGold standardTask executedParticipantsAim

Cutti 2008, [37]

Full-Text

M-IMU (n = 4),

Xsens MT9B

Unilateral:

Thorax (flat portion of the sternum), Scapula (central third, aligned with the cranial edge of the scapular spine), humerus (central third, slightly posterior), FA (distal)

Double-sided tape, elastic cuff

Sh ROM

(HT and ST joint angles)

RMSE = 0.2°-3.2°

VICON

Exp 1: elb FLX-EXT, PR-SU

sh FLX-EXT, IER, sh EL-DE and P-R

Exp 2: tasks in Exp1 + sh IER (arm abducted 90°), sh AB-AD (frontal plane),

HTN (sagittal and frontal plane)

HS (n = 1, M)Develop a protocol to measure humerothoracic, scapulothoracic and elbow kinematics

Parel 2012, [65]

Full-Text

M-IMU (n = 3),

Xsens MTx

Unilateral:

thorax, scapula, humerus

Elastic cuff, adhesive

Sh ROM

(HT and ST joint angles)

Humerus FLX-EXT (sagittal plane) and AB-AD (scapular plane)

HS (n = 20)

7F, 13 M

28.3 ± 5.5 Y

P (n = 20)

8F, 12 M

43.9 ± 19.9 Y

Assess the inta- and inter-operator agreement of ISEO protocol in measuring scapulohumeral rhythm

Daponte 2013a, [66]

Conference

M-IMU (n = 2), Zolertia Z1

Unilateral:

UA, FA

Brace

Sh ROM

Sh AB-AD

Elb FLX

HS (n = 1)Discuss design and implementation of a home rehabilitation system

Daponte 2013b, [67]

Conference

M-IMU (n = 2), Zolertia Z1

Unilateral:

UA, FA

Brace

Sh ROM,

Test1:

max gap =

6.5° (roll)

5.2° (pitch)

11.6° (yaw)

Test 1:

Tecno

Body MJS

Test 2: BTS

Test 1: shoulder IR, EL-DE and horizontal FLX-EXT

Test 2: elbow FLX-EXT (along sagittal and horizontal plane)

HS (n = 1, M)Validation of a home rehabilitation system

Pan 2013, [68]

Full-Text

Acc (n = 2),

LIS3LV02DQ

Acc built-in a Smartphone (n = 1)

Unilateral:

-acc: UA, thorax

-Smartphone: wrist

Strap, Armband

Sh ROM

(HT joint angles)

Touch ear

Use fingers to climb wall

Pendulum clockwise and counter clockwise

Active-assisted stretch fore and side, raises hand from back

HS (n = 10)

3 M, 7 F

20-25Y

P (n = 14)

5 M, 9 F

44–67 Y

Describe design and implementation of a shoulder joint home-based rehabilitation monitoring system

Thiemjarus 2013, [69]

Conference

Acc (n = 1),

Analog Device

(acc: ADXL330)

Magn (n = 1),

Honeywell

(magn: HMC5843)

Unilateral:

UA (proximal) or wrist, left or right

Strap

Sh ROM,

RMSE = 0.86°-5.05°

Sh FLX-EXT, AB-AD, horizontal AB-AD, IER

HS, (n = 23)

20–55 Y

Evaluate the effect of sensor placement on the estimation accuracy of shoulder ROM

Rawashdeh 2015, [70]

Conference

M-IMU (n = 1),

InvenSense (gyr: ITG-3200)

Analog Device (acc: ADXL 345)

Honeywell (magn: HMC5883L)

Unilateral:

UA (lateral)

Strap

Sh ROM

7 sh rehabilitation exercises

2 sports activities

HS (n = 11)Describe a detection and classification method of shoulder motion gestures that can be used to prevent shoulder injury

Álvarez 2016, [71]

Full-Text

M-IMU (n = 4),

Xsens MTx

Unilateral:

Back of the hand, FA (near wrist), UA (near elbow), back

Wristband, Velcro strap, elastic band

Sh ROM,

Lab test: mean error = 0.06° (FLX)

1.05° (lateral deviation)

Lab test:

robotic wrist

Test1: Mounting of a shock dumper system

Test2: holding a tablet for long periods

Test3: elbow FLX-EXT

Test1: Mechanical worker (n = 1)

Test2: worker of a commercial centre (n = 1)

Test3: patient (n = 1)

Demonstrate the feasibility of an IMU-based system to measure upper limb joint angles in occupational health

Lee 2016, [72]

Conference

Strain sensor (n = 2),

MWCNT, Hyosung: multi-walled carbon nanotubes, EcoFlex0030, Smooth-On: silicon rubber

Unilateral: Shoulder

Skin adhesive

Sh ROM, RMSE<10°OptiTrack

Sh FLX-EXT

Sh AB-AD

HS (n = 1)Validate sensors and calibration method estimating two shoulder joint angles

Tran e Vajerano 2016, [73]

Conference

M-IMU (n = 2),

Shimmer2r

Unilateral:

UA (distal, near elbow), FA (distal, near wrist)

Straps

Sh ROM

(HT joint angles)

Periodic arm movementsHS (n = 1)Validate an algorithm to predict the received signal strength indicator (RSSI) and the future joint-angle values of the user

Rawashdeh 2016, [74]

Full-Text

M-IMU (n = 1),

InvenSense (gyr: ITG-3200)

Analog Device (acc: ADXL 345)

Honeywell (magn: HMC5883L)

Unilateral:

UA (central third)

Straps

Sh ROM

(HT motion)

Visual observation7 sh rehabilitation exercises, baseball throws, volley serves

HS (n = 11)

25 ± 7 Y

Validate a detection and classification algorithm of upper limb movements

Wu 2016, [75]

Full-Text

M-IMU (n = 3), Bluetooth 3-Space Sensor, YEI

Unilateral: FA (near wrist), UA (near elbow), thorax (shifted to the right)

Strap, bandage

Sh ROM

(HT joint angles)

12 gestures common in daily life: 3 static and 9 dynamic

HS (n = 10)

9 M, 1 F

22–24 Y

Evaluate accuracy, recall and precision of a gesture recognition system

Burns 2018, [27]

Full-Text

Acc and gyr built-in a smartwatch (n = 1), Apple Watch (Series 2 &3)

Unilateral:

Wrist

Wristband

Sh ROM

Pendulum

AB

Forward EL

IR

ER

Trapezius EXT

Upright row

HS (n = 20)

14 M, 6 F

19–56 Y

Evaluate performance of a commercial smartwatch to perform home shoulder physiotherapy monitoring

Esfahani e Nussbaum 2018, [11]

Full-Text

Textile sensors (printed) n = 11

Bilateral:

Shoulder (n = 6), low back (n = 5)

Undershirt

Sh ROM, mean error = 9.6° for sh angle estimationM-IMU (Xsens MTw Awinda)

Sh AB

Sh FLX-EXT

Sh IER

Left/right side bending

Trunk FLX-EXT

Trunk rot left/right

HS (n = 16),

10 M, 6 F

21.9 ± 3.3

Describe a smart undershirt and evaluate its accuracy in task classification and planar angle measures in the shoulder joints and low back

Ramkumar 2018, [76]

Full-Text

Acc,gyr and magn built-in a smartphone, Apple iPhone

Unilateral:

UA, FA

Armband

Sh ROM <5°gon

AB (coronal plane)

forward FLX (sagittal plane)

IER (elbow fixed to the body flexed to 90°)

HS (n = 10)

5 M, 5 F

Mean 27 Y

Validate a motion-based machine learning software development kit for shoulder ROM

acc accelerometer, gyr gyroscope, magn magnetometer, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, ST scapulothoracic, Sh shoulder, elb elbow, FLX-EXT flexion-extension, AB-AD abduction-adduction, IER internal-external rotation, P-R protraction-retraction, RMSE root mean square error, HS Healthy subject, P patient, M male, F female, Y Years old

Table 4

Studies focused on validation/development of systems/algorithms for monitoring shoulder motion

Reference, Year, Type of publicationSensors, BrandPlacement and wearabilityTarget shoulder parameters, PerformanceGold standardTask executedParticipantsAim

Jung 2010, [77]

Conference

IMU (n = 6),

ADXL 345 (acc)

LPY51 50 AL (gyr)

HMC5843 (magn)

Bilateral:

UA and FA (distal third), thorax and pelvis

Strap

Sh orientation and positionHDRT system

Arms above head

Bend arms

Bend waist

HS (n = 1)Validate the motion tracking algorithm

El-Gohary 2011, [78]

Conference

IMU (n = 2),

APDM Opal

Unilateral:

FA (near wrist), UA (distal third)

Strap

Sh ROM,

r = 0.91–0.97

Eagle Analog System

Sh FLX-EXT

Sh AB-AD

Elb FLX-EXT

Elb PR-SU

HS (n = 1)Validate data fusion algorithm

Zhang 2011, [79]

Full-Text

M-IMU (n = 3),

Xsens MTx

Unilateral:

UA (laterally, above the elbow), FA (lateral and flat side of the FA near the wrist), sternum

Strap, clothing

Sh ROM,

RMSE = 2.4°

(sh FLX-EXT)

RMSE = 0.9°

(sh AB-AD)

RMSE = 2.9°

(sh IER)

BTS SMART-DFree movementsHS (n = 4)Validate sensor fusion algorithm

El-Gohary 2012, [80]

Full-Text

IMU (n = 2),

APDM Opal

Unilateral:

UA (middle third, slightly posterior), FA (distal, near wrist)

Strap band

Sh ROM,

RMSE = 5.5°

(sh FLX-EXT)

RMSE = 4.4°

(sh AB-AD)

VICON

Sh FLX-EXT

Sh AB-AD

Elb FLX-EXT

FA PR-SU

Touching nose

Reaching for a doorknob

HS (n = 8)Validate data fusion algorithm

Lee e Low 2012, [81]

Full-Text

Acc (n = 2), Freescale MMA7361 L

Unilateral:

UA (near elbow), FA (near wrist)

-

Sh ROM,

RMSE = 2.12°

(sh FLX-EXT)

RMSE = 3.68°

(sh rotation)

IMU

(Xsens MTx)

UA FLX-EXT and medial/lateral rotation

FA FLX-EXT

and PR-SU

(sagittal plane)

HS (n = 1)Validate the feasibility of the proposed algorithm

Hsu 2013, [82]

Conference

M-IMU (n = 2),

LSM303DLH

(acc, magn)

L3G4200D (gyr)

Unilateral:

UA, FA

Velcro strap

Sh ROM,

RMSE = 1.34°-5.08°

Xsens MTw, (n = 2)Sh FLX, AB, EXT, ER and IR

HS (n = 10)

8 M, 2 F

23.3 ± 1.33 Y

Validate data fusion algorithm

Lambrecht e Kirsch 2014, [16]

Full-Text

M-IMU (n = 4),

InvenSense MPU-9150 chip

Unilateral:

Sternum, UA, FA and hand

-

Sh ROM,

RMSE = 4.9°

(sh azimuth)

RMSE = 1.2°

(sh elevation)

RMSE = 2.9°

(sh IR)

OptotrackReaching movementsHS (n = 1)Validate sensors’ accuracy and data fusion algorithm

Ricci 2014, [83]

Full-Text

M-IMU (n = 5),

APDM Opal

Bilateral:

Thorax, UA (latero-distally) and FA (near wrist)

Velcro strap

Sh ROM

(HT joint angles)

UA FLX-EXT

UA AB-AD

FA PR-SU

FA FLX-EXT Thorax rotation

Thorax FLX-EXT

Children (n = 40)

6.9 ± 0.65 Y

Develop a calibration protocol for Thorax and upper limb motion capture

Roldan-Jimenez 2015, [84]

Full-Text

Inertial sensors built-in a Smartphone (n = 1),

LG Electronics INC, iPhone4

Unilateral:

UA

Neoprene arm belt

Sh ROMsh AB, EXT with wrist in neutral position and elb extended

HS (n = 10)

7 M, 3 F

24.2 ± 4.04 Y

Study humerus kinematics through six physical properties that correspond to angular mobility and acceleration in the three axes of space

Fantozzi 2016, [17]

Full-Text

M-IMU (n = 7),

APDM Opal

Bilateral:

Sternum, UA, FA, back of the hand

Velcro strap

Sh ROM

(HT joint angles),

RMSE <10° (sh FLX-EXT, AB-AD, IER)

BTS SMART-DXSimulated front-crawl and breaststroke swimming

HS (n = 8), M

26.1 ± 3.4 Y

Validate a protocol to assess the 3D joint kinematics of the upper limb during swimming

Meng 2016, [85]

Full-Text

M-IMU (n = 2), Shimmer2r

Unilateral:

UA (distal, near elbow), FA (distal, near wrist)

Straps

Sh ROM,

Test2: RMSE = from 2.20° to 0.87°

VICON

Sh FLX-EXT

Sh AB-AD

Sh IER

Elb FLX-EXT

Elb PR-SU

Test1:

HS (n = 15), M, 19–23 Y

Test2:

HS (n = 5)

Validate an algorithm to improve accuracy on measurements of arm joint angles considering the properties of human tissue

Crabolu 2017, [86]

Full-Text

M-IMU (n = 3), Xsens, MTw2 Awinda

Unilateral:

UA, scapula,

Sternum

Velcro strap, double-sided tape, elastic band

GH joint centerMRI acquisition

Cross and star motions

(2 joint velocities,

2 range of motions)

HS (n = 5)

3 M, 2 F

36 ± 4 Y

Evaluate accuracy and precision of the GHJC estimation

Kim 2017, [87]

Conference

MYO armband (n = 1): contains 8 EMG and 1 IMU, Thalamic Labs, MYO armband

Unilateral:

UA (near elbow)

Armband

Sh ROM

Elb FLX (0°,45°,90°) with sh in neutral position, elb FLX (0°,45°,90°) with sh FLX 90°

(sagittal plane)

HS (n = 1)Introduce an algorithm for upper arm and forearm motion estimation using MYO armband

Morrow 2017, [88]

Full-Text

M-IMU (n = 6), APDM Opal

Bilateral:

FA and UA (lateral), head, sternum

Velcro straps

Sh ROM

(HT joint angles), RMSE = 6.8° ± 2.7° (sh elevation)

Raptor 12 Digital Real Time Motion

Capture System

Peg transfer (to mimic minimally invasive laparoscopy)

Surgeon

HS (n = 6)

3 M, 3 F

45 ± 7 Y

Validate a M-IMU based protocol to measure shoulder EL, elbow FLX, trunk FLX-EXT and neck FLX-EXT kinematics

Rose 2017, [89]

Full-Text

IMU (n = 6), APDM Opal

Bilateral:

UA (lateral), FA (dorsal), sternum, lumbar spine

Straps

Sh ROM

(HT joint angles)

Diagnostic arthroscopy simulation

Surgeon

HS (n = 14)

Develop an IMU-based system to assess the performance of orthopaedic residents with different arthroscopic experiences

Tian 2017, [90]

Conference

M-IMU (n = 2), Acc: LIS3LV02D,

Magn: HMC5843,

Gyr: ITG3200

Unilateral:

UA, FA

Straps

Sh ROMVICONSh FLX and elb FLX (sagittal plane)HS (n = 1)Validate data fusion algorithm

Pathirana 2018, [91]

Full-Text

M-IMU (n = 1)

Unilateral:

Wrist

Strap

Sh ROM

VICON,

Kinect

Forward FLX-EXT

AB-AD

Backward FLX-EXT

Horizontal FLX-EXT

HS (n = 14)

10 M, 4 F

Validate accuracy and robustness of data fusion algorithm using a single sensor to measure shoulder joint angles

acc accelerometer, gyr gyroscope, magn magnetometer, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, GH glenohumeral, Sh shoulder, elb elbow, FLX-EXT flexion-extension, PR-SU pronation-supination, AB-AD abduction-adduction, IER internal-external rotation, RMSE root mean square error, r = correlation, HS Healthy subject, M male, F female, Y Years old

Shoulder motion monitoring for application in patients with musculoskeletal disorders Coley 2007, [29] Full-Text IMU (n = 2), Analog Device (gyr: ADXRS 250, acc: ADXL 21 0) Bilateral: humeri (posteriorly, distally) Adhesive patch Sh ROM (HT joint angles), RMSE =5.81° Mean = 1.80° Zebris CMS-HS Sh FLX-EXT Sh AB-AD Sh IER HS (n = 10), 25.1 ± 4.1 Y P (n = 10), 7 RC, 3 OA, 4 F, 6 M, 62.4 ± 10.4 Y Coley 2008, [30] Full-Text IMU (n = 4), Analog Device (gyr: ADXRS 250, acc: ADXL 21 0) Bilateral: humeri (posteriorly, distally), thorax Adhesive patch Sh ROM (HT joint angles) HS (n = 35) 32 ± 8 Y Jolles 2011, [31] Full.Text IMU (n = 4), Analog Device (gyr: ADXRS 250, acc: ADXL 21 0) Bilateral: Humeri (distally, posteriorly), thorax (× 2) Adhesive patch Sh ROM (HT joint angles), r = 0.61–0.80 P (n = 34) 27 RC, 7 OA 25 M, 9 F 57.5 ± 9.9 CG (n = 31) 17 M, 14 F 33.3 ± 8.0 Duc 2013, [5] Full-Text IMU (n = 3), Analog Device (gyr: ADXRS 250, acc: ADXL 210) Bilateral: Humeri (distal, posterior), sternum Adhesive patch Sh ROM (HT joint angles), r2 = 0.13-0.52 (CMS) r2 = 0.06-0.30 (DASH) r2 = 0.03-0.31 (SST) HS (n = 41) 34 ± 9 Y P (n = 21) 53 ± 9 Y RC (unilateral) Körver 2014, [32] Full-Text IMU (n = 2), Inertia-Link-2400-SKI, MicroStrain Bilateral: Humerus (distal, posterior) Adhesive Sh ROM (HT joint angles), r = 0.39 (DASH) r = 0.32 (SST) Hand to the back, Hand behind the head HS (n = 100) 37 M, 63 F 40.6 ± 15.7 Y P (n = 15) 5 M, 10 F 57.7 ± 10.4 Y, Subacromial impingement Van Den Noort 2014, [33] Full-Text M-IMU (n = 4), Xsens MTw Unilateral: Thorax, scapula, UA, FA Straps, skin tape Sh ROM (HT and ST joint angles) HS (n = 20) 3 M, 17 F 36 ± 11 Y Pichonnaz 2015, [34] Full-Text IMU (n = 3), Analog Device (acc: ADXL 210, gyr: ADXRS 250) Bilateral: Sternum, Humeri (posterior, distal) Skin tape Sh ROM (HT joint angles) Free movements (7 h) HS (n = 41) 23 M, 18 F 34.1 ± 8.8 Y P (n = 21) 14 M, 7 F 53.3 ± 9 Y RC Roldán-Jiménez e Cuesta-Vargas 2015, [35] Full-Text M-IMU (n = 4), InterSense InertiaCube3 Unilateral: Sternum, humerus, scapula, FA (near wrist) adhesive tape and bandage Sh ROM (HT and ST joint angles) HS (n = 11) 8 M, 3 F 24.7 ± 4.2 Y Van Den Noort 2015, [36] Full-Text M-IMU (n = 4), Xsens MTw Unilateral: Thorax, Scapula, UA, FA (ISEO protocol [33, 37]) Straps, skin tape Sh ROM (ST joint angles) P (n = 10) 8 M, 2 F 24–63 Y SD Roldán-Jiménez e Cuesta-Vargas 2016, [38] Full-Text Unilateral: Humerus (middle third, slightly posterior), scapula, sternum Double-sided tape, elastic bandage Sh ROM (GH and ST joint angles) Sh AB (frontal plane) Sh FLX (sagittal plane) Wri in neutral position and elb extended Young HS (n = 11), 18–35 Y 3 M, 8 F Adult HS (n = 14) > 40 Y 5 M, 9F Wang 2017, [26] Full-Text Unilateral: Shoulder (flat part of acromion), spine (C7-T1, T4-T5) Zipped vest, elastic strap with Velcro Sh ROM (ST joint angles), RMSE ~ 3.57° P with musculoskeletal shoulder pain (n = 8) 3 M, 5 F 50 ± 6.44Y Physiotherapist (n = 5) Aslani 2018, [39] Full-Text M-IMU (n = 1), Bosh Sensortec BNO055 EMG, MyoWare Muscle Sensor Unilateral: UA, deltoid (2 surface electrodes on each deltoid section) Band HS (n = 6) 4 M, 2 F 27.3 ± 3.4Y P (n = 1), M Frozen Sh 42 Y Carbonaro 2018, [40] Conference Unilateral: Sternum, FA (distal), scapula (similar to the configuration in [37]) Elastic bands Sh ROM (GH and ST joint angles) Extra-rotation, Arm AB (with different load) Hurd 2018, [41] Full-Text Acc buil.in ActiGraph (n = 2), ActiGraph GT3XP-BLE Unilateral: Wrist, UA (mid-biceps level) Velcro strap P (n = 14) 7 M, 7 F 73 ± 6Y GH OA, RC disease Langohr 2018, [6] Full-Text Bilateral: Sternum, UA (lateral aspects of the midhumerus), FA (dorsal aspect of the wrist) Shirt Daily activities (1 day, monitoring of 11 ± 3 h) P (n = 36) 73 ± 10 Y TSA, RTSA acc accelerometer, gyr gyroscope, magn magnetometer, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, ST scapulothoracic, GH glenohumeral, Sh shoulder, wri wrist, elb elbow, FLX-EXT flexion-extension, AB-AD abduction-adduction, IER internal-external rotation, RMSE root mean square error, r = correlation, r2, coefficient of determination, HS Healthy subject, CG Control Group, P patient, M male, F female, RC Rotator Cuff, OA Osteoarthritis, Y Years old, SST Simple Shoulder test, DASH Disability of the Arm, Shoulder and Hand, CMS Constant Murley Score Shoulder motion monitoring for application in patients with neurological disorders Bartalesi 2005, [8] Conference Strain sensor, WACKER Ltd. (ELASTOSIL LR 3162 A/B) Unilateral: Sensors’ segment series along right upper limb Shirt Hester 2006, [42] Conference Unilateral: thumb, index, back of the hand, FA and UA (medially), thorax Adhesive Zhou 2006, [43] Full-Text IMU (n = 2), Xsens MT9B Unilateral: Wrist (inwards), elbow (outwards) - FA FLX-EXT FA PR-SU, reach test Willmann 2007, [44] Conference M-IMU (n = 4), Philips Unilateral: Torso, shoulder, UA, FA Garment Zhou 2008, [45] Full-Text M-IMU (n = 2), Xsens MT9B Unilateral: FA (distally, near the wrist center), UA (laterally, on the line between the lateral epicondyle and the acromion process) Velcro straps Sh orientation and position, RMSE = 2.5°-4.8° reaching shrugging FA rotation HS (n = 4, M) 20–40 Y Giorgino 2009, [46] Full-Text Strain sensor (n = 19), WACKER Ltd. (ELASTOSIL LR 3162 A/B) Unilateral: Sensors’ sensing segments distributed over the UA, FA, shoulder, elbow, wrist Shirt GH FLX (sagittal plane) Lateral AB ER Lee 2010, [47] Full-Text Acc (n = 2), Freescale MMA7261 QT Unilateral: UA, FA Velcro strap Sh ROM, Mean error~0°-3.5° Chee Kian 2010, [48] Conference OLE (n = 1) Acc (n = 1) Unilateral: UA, elbow Adhesive patch Patel 2010, [49] Full-Text Unilateral: thumb, index, back of the hand, FA, UA, trunk - SP (n = 24) 57.5 ± 11.8 Y Pérez 2010, [15] Full-Text M-IMU (n = 4), Xsens MTi Unilateral: UA (18 cm from acromion), FA (25 cm from epicondyle), hand (5.5 cm from distal radio-cubital joint), back (position is not relevant) Strap Sh ROM, r = 0.997 (for sh IR, after calibration) Sh FLX-EXT Sh horizontal AB-AD Sh IR Elb FLX Elb PR-SU Wri FLX-EXT Serving water from a jar Bento 2011, [50] Conference Bilateral: Shoulder, UA, wrist (affected and unaffected side) Strap FA to Table FA to box Extend elbow Hand to table Hand to box SP (n = 5, M) 35–73 Y Nguyen 2011, [51] Full-Text OLE (n = 3) Acc (n = 3) Unilateral: Shoulder, elbow, wrist Clothing module fixed with Velcro straps Sh ROM, Test2: RMSE = 3.8° (gon), RMSE = 3.1° (SW) Test3: ICC = 0.975 (sh) Test2: gon, Shape- Wrap Test2: Bend and Flex elbow Test3: reaching task Test2: HS (n = 3, M); Test3: HS (n = 5) Ding 2013, [52] Full-Text M-IMU (n = 2), Analog Device (acc: ADXL320), HoneyWell (magn: HMC1 053), Silicon Sensing System (gyr) Unilateral: UA (distal, near elbow), FA (distal, near wrist) Velcro strap HS (n = 5) 20–27 Y Lee 2014, [53] Full-Text M-IMU (n = 7), Analog Device (acc:ADXL 345) InvenSense (gyr: ITG3200) Honeywell (magn: HMC5883L) Bilateral: Back, UA, FA and hand Strap Sh ROM, Test1: r = 0.963 Test2: RMSE< 5° Test1: gon Test2: VICON Sh FLX-EXT Sh AB Arm IER Elb FLX FA PR-SU Wri FLX-EXT Wri radial-ulnar deviation SP (n = 5) 2 M, 3 F Mean age: 68 Y Bai 2015, [54] Full-Text M-IMU (n = 4 or n = 1), Xsens MTx Unilateral Scapula, UA, FA, back of the hand or only on UA Velfoam, Velcro straps Sh ROM (upper limb segments orientation and position) Test1: gon Test2: gon, VICON Sh FLX-EXT Sh IER Sh AB-AD Elb FLX-EXT FA PR-SU Wri FLX-EXT Wri radial-ulnar deviation HS (n = 10) 8 M, 2 F 20–38 Y P (n = 1), F 41 Y Ertzgaard 2016, [55] Full-Text IMU (n = 5), Analog Device, Adis 16,350 Bilateral: Back (upper body), UA and FA Strap Sh ROM (HT joint angles), ICC = 0.768–0.985 HS (n = 10) 2 M, 8 F 34.3 ± 13.1Y SP (n = 1), F, 43 Y Lorussi 2016, [56] Full-Text M-IMU (n = 2), Xsens MTw Strain sensor (n = 1), Smartex Unilateral: M-IMU sensors on sternum and UA Textile-based strain sensor on the back (from the spine to scapula) Shirt Sh ROM (HT joint angle and scapular translation) UA FLX (sagittal plane) UA AB (frontal plane) Mazamenos 2016, [57] Full-Text M-IMU (n = 2), Shimmer2r Unilateral: UA (distal, near elbow), FA (distal, near wrist) Straps EXP1: Reach and retrieve, lift object to mouth, rotate an object EXP2: preparing a cup of tea HS (n = 18) M, F 25–50 Y SP (n = 4) M, F 45–73 Y Jiang 2017, [58] Conference Acc (n = 4), Analog Device ADXL362 EMG (n = 4), Analog Device AD8232 Temperature (n = 1) Unilateral: along upper limb Shirt Li 2017, [59] Full-Text IMU (n = 2), InvenSense, MPU-9250 EMG (n = 10), American Imex, Dermatrode Unilateral: IMU: UA, wrist EMG: FA (n = 8), UA (n = 2) Stretchable belt 11 tasks including: Sh FLX, Sh AB Wri FLX-EXT, Fetch and hold a ball or a cylindric roll, finger to nose, touch the back of the sh, FA PR-SU HS (n = 16) 10 M, 6 F 36.25 ± 15.19Y SP (n = 18) 11 M, 7 F 55.28 ± 12.25 Y Newman 2017, [60] Full-Text Bilateral: sternum, UA (posterior) Velcro straps, adhesive patch Sh ROM (HT joint angles) Children (n = 30) 10.6 ± 3.4 Y 17 boys, 13 girls Yang e Tan 2017, [61] Conference Unilateral: Waist, thorax, UA (distal, near elbow), FA (distal, near elbow) Straps Sh ROM (HT joint angles) Daunoraviciene 2018, [62] Full-Text Bilateral: UA, FA, hand (on centres of mass) Strap CG (n = 24) 7 M 31.14 ± 5.67 17 F 28 ± 3.97 MS-P (n = 34) 13 M 36.46 ± 13.07 21 F 42.19 ± 12.55 Jung 2018, [63] Conference Bilateral: UA and FA, trunk Velcro straps Sh ROM (HT join angles), RMSE = 0.32 for the estimation of movements qualities using data of the entire duration of movements SP (n = 5), F 66.6 ± 15.9 Y Lin 2018, [64] Full-Text Unilateral: UA (distal, near elbow), FA (dorsal aspect of the wrist) Strap Sh FLX-EXT Sh AB Sh ER Elb FLX FA PR-SU SP (n = 18): n = 9, control group (62.6 ± 7.1) n = 9, device group (52.2 ± 10.2 Y) Repnik 2018, [7] Full-Text M-IMU (n = 7), Myo armband, n = 2_ with n = 8 EMGs built-in, Thalamic labs Bilateral: -M-IMU: Back of the hand, wrist, UA (distal, near elbow), sternum -MYO: FA (in the proximity of elbow joint) Straps, armband Sh ROM (HT joint angles) SP (n = 28) 18 M, 10 F 57 ± 9.1 Y HS (n = 12) 9 M, 3 F 36 ± 8 Y acc accelerometer, gyr gyroscope, magn magnetometer, OLE Optical Linear Encoder, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, GH glenohumeral, Sh shoulder, wri wrist, elb elbow, FLX-EXT flexion-extension, PR-SU pronation-supination, AB-AD abduction-adduction, IER internal-external rotation, RMSE root mean square error, r = correlation, ICC Intraclass Correlation Coefficients, gon goniometer, HS Healthy subject, CG control group, SP Stroke Patient, MS-P Multiple Sclerosis Patient, P patient, M male, F female, Y Years old, FAS Functional Ability Scale, ARAT Action research arm test Shoulder motion monitoring for application in patients undergoing rehabilitation Cutti 2008, [37] Full-Text M-IMU (n = 4), Xsens MT9B Unilateral: Thorax (flat portion of the sternum), Scapula (central third, aligned with the cranial edge of the scapular spine), humerus (central third, slightly posterior), FA (distal) Double-sided tape, elastic cuff Sh ROM (HT and ST joint angles) RMSE = 0.2°-3.2° Exp 1: elb FLX-EXT, PR-SU sh FLX-EXT, IER, sh EL-DE and P-R Exp 2: tasks in Exp1 + sh IER (arm abducted 90°), sh AB-AD (frontal plane), HTN (sagittal and frontal plane) Parel 2012, [65] Full-Text M-IMU (n = 3), Xsens MTx Unilateral: thorax, scapula, humerus Elastic cuff, adhesive Sh ROM (HT and ST joint angles) HS (n = 20) 7F, 13 M 28.3 ± 5.5 Y P (n = 20) 8F, 12 M 43.9 ± 19.9 Y Daponte 2013a, [66] Conference Unilateral: UA, FA Brace Sh AB-AD Elb FLX Daponte 2013b, [67] Conference Unilateral: UA, FA Brace Sh ROM, Test1: max gap = 6.5° (roll) 5.2° (pitch) 11.6° (yaw) Test 1: Tecno Body MJS Test 2: BTS Test 1: shoulder IR, EL-DE and horizontal FLX-EXT Test 2: elbow FLX-EXT (along sagittal and horizontal plane) Pan 2013, [68] Full-Text Acc (n = 2), LIS3LV02DQ Acc built-in a Smartphone (n = 1) Unilateral: -acc: UA, thorax -Smartphone: wrist Strap, Armband Sh ROM (HT joint angles) Touch ear Use fingers to climb wall Pendulum clockwise and counter clockwise Active-assisted stretch fore and side, raises hand from back HS (n = 10) 3 M, 7 F 20-25Y P (n = 14) 5 M, 9 F 44–67 Y Thiemjarus 2013, [69] Conference Acc (n = 1), Analog Device (acc: ADXL330) Magn (n = 1), Honeywell (magn: HMC5843) Unilateral: UA (proximal) or wrist, left or right Strap Sh ROM, RMSE = 0.86°-5.05° HS, (n = 23) 20–55 Y Rawashdeh 2015, [70] Conference M-IMU (n = 1), InvenSense (gyr: ITG-3200) Analog Device (acc: ADXL 345) Honeywell (magn: HMC5883L) Unilateral: UA (lateral) Strap 7 sh rehabilitation exercises 2 sports activities Álvarez 2016, [71] Full-Text M-IMU (n = 4), Xsens MTx Unilateral: Back of the hand, FA (near wrist), UA (near elbow), back Wristband, Velcro strap, elastic band Sh ROM, Lab test: mean error = 0.06° (FLX) 1.05° (lateral deviation) Lab test: robotic wrist Test1: Mounting of a shock dumper system Test2: holding a tablet for long periods Test3: elbow FLX-EXT Test1: Mechanical worker (n = 1) Test2: worker of a commercial centre (n = 1) Test3: patient (n = 1) Lee 2016, [72] Conference Strain sensor (n = 2), MWCNT, Hyosung: multi-walled carbon nanotubes, EcoFlex0030, Smooth-On: silicon rubber Unilateral: Shoulder Skin adhesive Sh FLX-EXT Sh AB-AD Tran e Vajerano 2016, [73] Conference M-IMU (n = 2), Shimmer2r Unilateral: UA (distal, near elbow), FA (distal, near wrist) Straps Sh ROM (HT joint angles) Rawashdeh 2016, [74] Full-Text M-IMU (n = 1), InvenSense (gyr: ITG-3200) Analog Device (acc: ADXL 345) Honeywell (magn: HMC5883L) Unilateral: UA (central third) Straps Sh ROM (HT motion) HS (n = 11) 25 ± 7 Y Wu 2016, [75] Full-Text Unilateral: FA (near wrist), UA (near elbow), thorax (shifted to the right) Strap, bandage Sh ROM (HT joint angles) HS (n = 10) 9 M, 1 F 22–24 Y Burns 2018, [27] Full-Text Unilateral: Wrist Wristband Pendulum AB Forward EL IR ER Trapezius EXT Upright row HS (n = 20) 14 M, 6 F 19–56 Y Esfahani e Nussbaum 2018, [11] Full-Text Bilateral: Shoulder (n = 6), low back (n = 5) Undershirt Sh AB Sh FLX-EXT Sh IER Left/right side bending Trunk FLX-EXT Trunk rot left/right HS (n = 16), 10 M, 6 F 21.9 ± 3.3 Ramkumar 2018, [76] Full-Text Unilateral: UA, FA Armband AB (coronal plane) forward FLX (sagittal plane) IER (elbow fixed to the body flexed to 90°) HS (n = 10) 5 M, 5 F Mean 27 Y acc accelerometer, gyr gyroscope, magn magnetometer, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, ST scapulothoracic, Sh shoulder, elb elbow, FLX-EXT flexion-extension, AB-AD abduction-adduction, IER internal-external rotation, P-R protraction-retraction, RMSE root mean square error, HS Healthy subject, P patient, M male, F female, Y Years old Studies focused on validation/development of systems/algorithms for monitoring shoulder motion Jung 2010, [77] Conference IMU (n = 6), ADXL 345 (acc) LPY51 50 AL (gyr) HMC5843 (magn) Bilateral: UA and FA (distal third), thorax and pelvis Strap Arms above head Bend arms Bend waist El-Gohary 2011, [78] Conference IMU (n = 2), APDM Opal Unilateral: FA (near wrist), UA (distal third) Strap Sh ROM, r = 0.91–0.97 Sh FLX-EXT Sh AB-AD Elb FLX-EXT Elb PR-SU Zhang 2011, [79] Full-Text M-IMU (n = 3), Xsens MTx Unilateral: UA (laterally, above the elbow), FA (lateral and flat side of the FA near the wrist), sternum Strap, clothing Sh ROM, RMSE = 2.4° (sh FLX-EXT) RMSE = 0.9° (sh AB-AD) RMSE = 2.9° (sh IER) El-Gohary 2012, [80] Full-Text IMU (n = 2), APDM Opal Unilateral: UA (middle third, slightly posterior), FA (distal, near wrist) Strap band Sh ROM, RMSE = 5.5° (sh FLX-EXT) RMSE = 4.4° (sh AB-AD) Sh FLX-EXT Sh AB-AD Elb FLX-EXT FA PR-SU Touching nose Reaching for a doorknob Lee e Low 2012, [81] Full-Text Unilateral: UA (near elbow), FA (near wrist) - Sh ROM, RMSE = 2.12° (sh FLX-EXT) RMSE = 3.68° (sh rotation) IMU (Xsens MTx) UA FLX-EXT and medial/lateral rotation FA FLX-EXT and PR-SU (sagittal plane) Hsu 2013, [82] Conference M-IMU (n = 2), LSM303DLH (acc, magn) L3G4200D (gyr) Unilateral: UA, FA Velcro strap Sh ROM, RMSE = 1.34°-5.08° HS (n = 10) 8 M, 2 F 23.3 ± 1.33 Y Lambrecht e Kirsch 2014, [16] Full-Text M-IMU (n = 4), InvenSense MPU-9150 chip Unilateral: Sternum, UA, FA and hand - Sh ROM, RMSE = 4.9° (sh azimuth) RMSE = 1.2° (sh elevation) RMSE = 2.9° (sh IR) Ricci 2014, [83] Full-Text M-IMU (n = 5), APDM Opal Bilateral: Thorax, UA (latero-distally) and FA (near wrist) Velcro strap Sh ROM (HT joint angles) UA FLX-EXT UA AB-AD FA PR-SU FA FLX-EXT Thorax rotation Thorax FLX-EXT Children (n = 40) 6.9 ± 0.65 Y Roldan-Jimenez 2015, [84] Full-Text Inertial sensors built-in a Smartphone (n = 1), LG Electronics INC, iPhone4 Unilateral: UA Neoprene arm belt HS (n = 10) 7 M, 3 F 24.2 ± 4.04 Y Fantozzi 2016, [17] Full-Text M-IMU (n = 7), APDM Opal Bilateral: Sternum, UA, FA, back of the hand Velcro strap Sh ROM (HT joint angles), RMSE <10° (sh FLX-EXT, AB-AD, IER) HS (n = 8), M 26.1 ± 3.4 Y Meng 2016, [85] Full-Text Unilateral: UA (distal, near elbow), FA (distal, near wrist) Straps Sh ROM, Test2: RMSE = from 2.20° to 0.87° Sh FLX-EXT Sh AB-AD Sh IER Elb FLX-EXT Elb PR-SU Test1: HS (n = 15), M, 19–23 Y Test2: HS (n = 5) Crabolu 2017, [86] Full-Text Unilateral: UA, scapula, Sternum Velcro strap, double-sided tape, elastic band Cross and star motions (2 joint velocities, 2 range of motions) HS (n = 5) 3 M, 2 F 36 ± 4 Y Kim 2017, [87] Conference Unilateral: UA (near elbow) Armband Elb FLX (0°,45°,90°) with sh in neutral position, elb FLX (0°,45°,90°) with sh FLX 90° (sagittal plane) Morrow 2017, [88] Full-Text Bilateral: FA and UA (lateral), head, sternum Velcro straps Sh ROM (HT joint angles), RMSE = 6.8° ± 2.7° (sh elevation) Raptor 12 Digital Real Time Motion Capture System Surgeon HS (n = 6) 3 M, 3 F 45 ± 7 Y Rose 2017, [89] Full-Text Bilateral: UA (lateral), FA (dorsal), sternum, lumbar spine Straps Sh ROM (HT joint angles) Surgeon HS (n = 14) Tian 2017, [90] Conference M-IMU (n = 2), Acc: LIS3LV02D, Magn: HMC5843, Gyr: ITG3200 Unilateral: UA, FA Straps Pathirana 2018, [91] Full-Text Unilateral: Wrist Strap VICON, Kinect Forward FLX-EXT AB-AD Backward FLX-EXT Horizontal FLX-EXT HS (n = 14) 10 M, 4 F acc accelerometer, gyr gyroscope, magn magnetometer, IMU Inertial Measurement Unit, M-IMU Magneto and Inertial Measurement Unit, UA Upper Arm, FA Forearm, ROM Range of motion, HT humerothoracic, GH glenohumeral, Sh shoulder, elb elbow, FLX-EXT flexion-extension, PR-SU pronation-supination, AB-AD abduction-adduction, IER internal-external rotation, RMSE root mean square error, r = correlation, HS Healthy subject, M male, F female, Y Years old

Sensing technology

Some studies combined different sensors in their measurements system. The most used sensors are accelerometers, gyroscopes and magnetometers, a combination of them (n = 55) or with other sensors (n = 8), or built-in into other devices (e.g., smartphones, smartwatch) (n = 6); additional studies (n = 4) utilized strain sensors for motion analysis.

B.1 wearable systems based on inertial sensors and magnetometers

An IMU allows estimating both translational and rotational movements. Such sensors comprise gyroscopes that measure angular velocity and accelerometers that measure proper acceleration, i.e. gravitational force (static) and force due to movements (dynamic) [92]. The main limitation of the gyroscopes is the issue bias due to drift. Gyroscopes do not have an external reference, as opposed to accelerometers that use gravity vector as reference; in the orientation estimation, gyroscopes suffer of drift during the integration procedures. To compensate such issue, these sensors are combined with magnetometers that measure magnetic field and use the Earth’s magnetic field as reference. The main limitation of magnetometers is the interference due to the presence of ferromagnetic materials in the surrounding environment [92]. We refer to these hybrid sensors as M-IMU (magnetic and inertial measurement unit). By integrating the information derived from each sensor (i.e., acceleration, angular velocity and magnetic field) through sensor-fusion algorithms, M-IMUs provide an accurate estimation of the 3D-position and 3D-orientation of a rigid body. The upper limb can be modelled as a kinematic chain constituted by a series of rigid segments, i.e., thorax, upper arm, forearm and hand, linked to each other by joints that allow relative motion among consecutive links [17]. In the kinematic chain, the shoulder joint consists of three degrees of freedom (DOFs) correspondent to abduction-adduction (AB-AD), internal-external rotation (IER), and flexion-extension (FLX-EXT) [15, 54, 57, 71, 79]. Shoulder rotations can be described using Euler angles that identify the anatomical DOFs with the roll-pitch-yaw angles [17, 33, 37, 88]. Sensor-fusion algorithms can exploit two main approaches, deterministic or stochastic. The deterministic approach includes the complementary filter that merges a high pass filter for gyroscope data (to avoid drift) and a low pass filter for accelerometer and magnetometer data [64, 82, 90, 92]. The stochastic approach includes the Kalman Filter and its more sophisticated versions [7, 55, 66, 67, 78–80, 91, 92]. The Kalman filter (KF) is the most used algorithm to process M-IMU and IMU data due to its accuracy and reliability [15, 38, 54, 75, 83, 93]. Wearable systems based on IMU or M-IMU include a variable number of sensor nodes that, properly distributed on each body segment of interest, provide kinematic parameters such as joint ROM, position, orientation, and velocity. Fifty-one out of the included studies used exclusively IMUs (n = 15) or M-IMUs (n = 36). Systems performances were analyzed in terms of the agreement between results obtained from the M-IMU or IMU-based systems and those collected by a gold standard system. Several types of systems were used as gold standard, such as ultrasound-based system (e.g., Zebris CMS-HS [29]), diagnostic imaging (e.g., Magnetic Resonance [86]), optical-based systems (e.g., VICON [37, 53, 54, 80, 85, 90, 91], BTS Bioengineering [15, 17, 56, 67, 79], Eagle Analogue System [78], Optotrack [16], Optitrack [61], CODA [45, 55]), goniometer [53, 54]. Results from an inertial system were benchmarked against an ultrasound-based reference system, showing a root mean square error (RMSE) of 5.81° and a mean error of 1.80° in the estimation of shoulder angles of FLX-EXT, AB-AD and IER evaluated in the sagittal, frontal and transversal planes, respectively [29]. Accuracy of a protocol based on commercial inertial sensors (MT9B, Xsens) was tested and compared to a VICON system to measure humerothoracic, scapulothoracic joint angles and elbow kinematics [37]. Results demonstrated high accuracy in the estimation of upper limb kinematics with an RMSE lower than 3.2° for 97% of data pairs. A BTS reference system was used to validate accuracy of a wearable system comprised of commercial sensors (Xsens) and results showed a mean error difference of 13.82° for FLX-EXT, 7.44° for AB-AD, 28.88° for IR [15]. In a protocol-validation study, commercial Opal sensors were compared to a BTS system to assess upper limb joint kinematics during simulated swimming movements. Data showed a median RMSE always better than 10° considering movements of AB-AD, IER and FLX-EXT in front-crawl and breaststroke [17]. Opal wearable sensors were compared to optical motion capture systems to estimate shoulder and elbow angles [78, 80]. Planar shoulder FLX-EXT and AB-AD were performed showing an RMSE of 5.5° and 4.4°, respectively [80]; a good correlation between the measurements performed on shoulder motion with the two systems was also found in [78] (no data regarding measurements error were proposed). Some studies (n = 11) compared data obtained from wearable sensors, custom or commercial, with a gold standard to validate their own sensors data fusion algorithm (for more details see Table 4). Two different algorithms were compared to a customized KF [79]. Comparing the results derived from the BTS system and the inertial-based system (Xsens), the proposed algorithm showed a smaller error than the other two methods for computing shoulder FLX-EXT (RMSE = 2.4°), AB-AD (RMSE = 0.9°), IER (RMSE = 2.9°) [79]. The addition of the magnetometer-based heading correction in the sensor data fusion algorithm was investigated to test the accuracy of an inertial-based motion tracking system using the Optotrak Certus (Northern Digital Inc., Waterloo, ON, Canada) as reference. Results showed a RMSE of 4.9°, 1.2° and 2.9° for shoulder azimuth, elevation and internal rotation, respectively [16]. Four studies used only accelerometers [42, 47, 49, 81]. Systems performance analysis in measurement of arm motion, showed a RMSE lower than 3.5° and 3.68° for shoulder ROM when results from the accelerometers-based systems were benchmarked against a goniometer and commercial M-IMUs, respectively [47, 81]. Evaluation of upper limbs’ physical activity was performed recording data of accelerometers built-in wearable device as ActiGraph (Pensacola, Florida, Model GT3XP-BTLE) to obtain objective outcomes in patients after reverse shoulder arthroplasty [41]. Shoulder ROM has been also estimated by means of a single sensor node which integrated an accelerometer and a magnetometer [69]. Sensor fusion algorithms of accelerometers and magnetometers data provide accurate orientation estimation in static or semi static condition, e.g., in a rehabilitation session in which patients perform slow movements [81]. M-IMUs comprised of a 3D accelerometer, 3D gyroscope and 3D magnetometer are the most appropriate choice for motion tracking either in static that in dynamic condition. Two accelerometer-based sensors were combined with those built-in a smartphone to realize a smart rehabilitation platform for shoulder home-rehabilitation [68]. Mobile phone or a smartwatch, with their built-in inertial sensor units, were used as mobile monitoring devices [27, 76, 84]. These results give proof of the growing trend in the application of commercial devices in clinical setting for rehabilitation purposes. Data has been processed using machine learning algorithms to extract salient features and for gesture recognition related to shoulder motion. In these techniques, the main steps are the data collection, followed by segmentation process, feature extraction and classification [27, 49]. For instance, the identification of different types of RC physiotherapy exercises has been performed processing data from inertial sensors built-in a wrist-worn smartwatch [27]. Data from inertial sensors built-in a smartphone were benchmarked against a manual goniometer. Angular differences between a machine learning-based application and goniometer measurements resulted less than 5° for all shoulder ROM (i.e., AD, forward FLX, IR, ER) [76]. Two studies combined accelerometer(s) with Optical Linear Encoder (OLE) [68, 84]. An OLE-based system acts as a goniometer providing measures of joint angles. Despite of the simplicity and low cost of the proposed systems, differences in shoulder ROM estimation resulted not negligible when data collected by the wearable systems were compared against an inertial-based motion capture (i.e., IGS-190 [54]) and a fiber optics-based system (i.e., ShapeWrap [71]). Three studies included EMG sensors in their assessment tool in combination with accelerometers [58], IMUs [59] and M-IMU [39]. EMG sensors placed on the biceps, triceps [59] and deltoid muscles [39] provide additional information about upper limb motor function and shoulder assessment, evaluating muscles activity. Quantification of upper limb motion was executed through a wearable device, MYO armband by Thalamic labs, that combines EMG sensors to record electrical impulses of the muscles [7, 87].

B.2 wearable systems based on strain sensors

Four studies used smart-textiles instrumented by strain sensors with piezoresistive properties to estimate kinematic parameters and to perform motion analysis [8, 11, 46, 56]. Such sensing elements are stretched or compressed during movements of the examined body segments, with consequent variation of their electrical resistance [94, 95]. Using a M-IMU system as reference, accuracy evaluation of a smart-textile with printed strain sensors showed a mean error of 9.6° in planar motions measurements of shoulder joint [11]. Shoulder kinematics was assessed combining a strain sensor for scapular sliding detection with two M-IMUs for HT orientation measure [56]. Piezoresistive strain sensors directly adhered to the skin were used to estimate shoulder ROM; the comparison between reference data from an optical-based system (i.e., Optitrack) and strain sensors showed a RMSE less than 10° in shoulder FLX-EXT and AB-AD estimation [72].

Sensors placement and wearability

Placement of the sensing technology on the body landmarks has shown a heterogeneous distribution linked to the different nature of the employed technology and to the purpose for which monitoring system was designed. With respect to the monitored upper limb, 53 out of the 73 studies included in this review showed a unilateral distribution of the sensing elements while the remaining studies utilized a bilateral placement. Several configurations using different number of sensors and placements have been investigated as reported in detail in each table and Fig. 2.
Fig. 2

Placement of sensing units (NOTE One study [90] is not included because the specific position of each sensor nodes is not so clear. Legend: N = number of studies, U = Unilateral, B = Bilateral)

Placement of sensing units (NOTE One study [90] is not included because the specific position of each sensor nodes is not so clear. Legend: N = number of studies, U = Unilateral, B = Bilateral) Regarding the wearability, we classified the systems in terms of how the sensors were fixed to the human body: i) by adhesive patch, ii) by means of straps or embedded within pocket, iii) the sensing element is physically integrated into the fabric. Four studies did not specify the method of attachment, 12 studies have stuck sensors directly on human skin by means of adhesive patch, 52 studies have attached sensors through straps or embedding them in modular clothing, and 5 studies have integrated sensors directly into garments. For more details refers to Tables 1, 2, 3 and 4.

Discussion

This paper summarizes the main features of wearable systems that have been employed in clinical setting and research field to evaluate upper limb functional performance and particularly for shoulder ROM assessment. Shoulder complex is characterized by the greatest mobility among all human joints and, due to its complexity, reviewed articles evidenced heterogeneity on the more suitable protocol for capturing joint ROM [96].

Wearable technology

Although 73% of the reviewed papers use commercial products for tracking joint angles, many of these personalize the positioning of the sensors, the calibration methodology and the algorithms used to process the recorded data. This customization makes strenuous a direct comparison among protocols, especially if sensing units of different nature (e.g., M-IMU vs. strain sensors) are used to measure the same kinematic parameters, leaving still open the issue of the protocols’ definition with general validity. About studies using inertial-based motion tracking systems, most in this summary (88%), calibration procedures before data acquisition and data processing represent a relevant issue about accuracy and reliability of the system. Typically, the M-IMUs are attached on the segment of interest to estimate its orientation, so the calibration is necessary to relate sensors’ measurements to movements of the tracked body segment. Sometimes the manufacturer suggests how to perform calibration, e.g., positioning sensors on a flat surface [15, 35] to align coordinate system or assuming static anatomical position [65], as N-pose [79], to compute orientation differences between segments and sensors coordinates in order to obtain sensor-to-segment alignment [56]. Dynamic or functional anatomical calibration has also been performed in some studies, but the sequence of movements executed varied among these [17, 33, 55, 83]. One interesting improvement that may be done to have a positive impact on the accuracy of inertial-based motion tracking systems, is to define a standard set of movements for the initial calibration and a standard method of data processing by which extrapolate kinematic parameters of high clinical relevance. Some works have reported remarkable results in human motion tracking using e-textile sensors [8, 46]. Technological improvements in the development of conductive elastomers allowed to integrate such strain sensors directly into garments making them comfortable and unobtrusive [11, 56]. Although conductive elastomers ensure flexibility and performances comparable with those of the M-IMU sensors, the main limitations are the hysteresis, uniaxial measurements and non-negligible transient time [56]. Wearable systems based on strain sensors are a promising technology for kinematics analysis that may overcome the main M-IMUs drawbacks, as interferences due to surrounding ferromagnetic materials, gyroscopes’ error drift and long-term use. On the other hand, errors may occur with strain sensors-based systems in the estimation of shoulder kinematics for their inherent hysteresis behaviour. Among wearable systems reviewed in this summary, differences resulted in terms of sensors typology, number and size, placement, and wearability features. Sensors placement and method of attachment must be carefully investigated as they could influence the outcomes reliability (e.g., effects of soft tissues’ artefacts). Human skeleton is covered by skin tissue and muscles. The combination of skin’s elasticity and muscle activity may cause negative effects in the measurement of the bones’ movement. In studies where M-IMU sensors were used to track shoulder kinematics, soft tissue properties were opportunely included in mathematical models to reduce soft tissue artifacts [79, 85]. The body fat percentage was found the main influencing factor that negatively affects the inertial sensors’ orientation [85]. To reduce such source of error, either when sensors are directly adherent to the skin that embedded in a textile, sensing units should be placed as near as possible to the bone segment to reduce soft tissue artifacts [97, 98]. Wearability is a key factor to consider because it can influence the level of patients’ acceptance [26].There are several relevant requirements that wearable systems must meet to encourage their applications in continuous monitoring of patient status. Indeed, execution of movements, either in home environments or in clinical settings, should not be hindered by measurements systems so they must be non-invasive, modular, lightweight, unobtrusive and include a minimal number of sensors [33, 40, 51, 56, 66, 67, 91]. Most studies have employed magneto and inertial-based tracking systems in which sensors were attached to the upper limb through Velcro straps or including them in modular brace and garments [26, 45, 67, 82, 88]. Upper limb includes the shoulder, elbow and wrist joints (Fig. 3a). Humerus, scapula, clavicle, and thorax constitute the shoulder complex: humeral head articulates in the glenoid fossa of the scapula to form GH joint, the AC joint is the articulation between the lateral end of the clavicle and the acromion process, the SC joint articulates the medial end of the clavicle and the sternum and the functional ST joint allows rotational and translational movements of the scapula with respect to the thorax [96] (Fig. 3b). The ST joint and GH joint act togheter in arm elevation according to scapular-humeral rhythm described in [99]. From a biomechanical point of view, shoulder complexity is justified by the high degree of coupling and coordination between shoulder joints (i.e., shoulder rhythm) and the action of more than one muscles over more than one joints in the execution of a movement. Data extraction of shoulder kinematics is frequently based on movements pattern in the sagittal, frontal and transversal planes, so monitoring of complex movements (e.g., daily activities) in multiple planes, performed through wearable sensors, requires a more stringent evaluation and accurate interpretation. As resulted in the review, the shoulder is generally approximated as a ball-and-socket joint [56]. This assumption provides an approximate representation of the whole shoulder girdle (e.g., it neglects the contribution of scapular movements). A standardized protocol has been proposed (i.e., The ISEO®, INAIL Shoulder and Elbow Outpatient protocol) to improve the performance of M-IMUs in the estimation of scapular kinematics, by locating inertial sensors on the back in correspondence of scapula [33, 35–38, 40, 65]. An adequate investigation of scapular motions may be beneficial to assess shoulder disorders [100].
Fig. 3

a Anatomy of the Upper limb; b Anatomy of the Shoulder complex

a Anatomy of the Upper limb; b Anatomy of the Shoulder complex For long-term monitoring of shoulder kinematics considering also scapular motions, the combination of M-IMUs and smart-textile with embedded strain sensors is a perfect balancing of accuracy, flexibility and wearability (i.e., strain sensors positioned on the scapula could increase the portability and acceptance of the wearable system for long-term monitoring of ADLs) [86].

Applicability in clinical setting and rehabilitation

Alterations in the complex shoulder kinematics can derive by both neurological or musculoskeletal disorders and result in pain and limited movements [68]. Compensatory movements in patients with shoulder disorders are the most common consequential responses to pain or to difficulty in performing free-pain movements. In such situations, information retrieved by posture monitoring may be beneficial in clinical application and rehabilitation [26]. In the last years, the application of wearable devices for gathering motion data outside the laboratory settings is growing. Avoiding complex laboratory set-up, wearable systems employed to assess upper limb kinematics have proven to be a well-founded alternative to obtain quantitative motions parameters. Quantitative outcomes about shoulder motions recorded by wearable sensors are beneficial in clinical practice in terms of time-saving and they are becoming a promising alternative to improve assessment accuracy overcoming the subjectivity of clinical scales. The automatic assessment of motor abilities can also provide therapists a tangible and, therefore, measurable awareness of the effectiveness of the treatment and the recovery path chosen. In clinical practice, the severity level of patients’ condition with musculoskeletal disease is usually assessed through questionnaire-based scores [36, 42]. Algorithms for kinematic scores computing were developed to evaluate shoulder functional performance after surgery in subjects with GH osteoarthritis and RC diseases, elaborating data obtained from IMU sensors [29, 31]. High correlation (0.61–0.8) between shoulder kinematic scores (i.e., power score, range of angular velocity score and moment score) and clinical scales (e.g., DASH, SST, VAS) was found [31]. Unlike clinical scores, kinematic scores showed greater sensitivity in detecting significant functional changes in shoulder activity at each post-operative follow-up with respect to the baseline status [29, 31]. In a five-year follow-up study, asymmetry in shoulder movements was evaluated in patients with subacromial impingements syndrome. Asymmetry scores, derived from an IMU-based system, showed post-treatment improvements with greater sensitivity than clinical scores and only a weak correlation was found with DASH (r = 0.39) and SST (r = 0.32) [32]. Quantitative evaluation of arm usage and quality of movements in every kind of shoulder impairment contributes to outline a clinical picture about the functional recovery and the effectiveness of the treatment [30, 49]. Using the same number of IMU (n = 3) and the same placement on both humeri and sternum, the shoulder function was evaluated before and after treatment, in patients underwent surgery for RC tear [5, 34]. Results showed significative differences in movements frequency between patients and control group during activities of daily life [5], with limited use of arm at 3 months after surgery [34]. With a bilateral configuration based on 5 IMU, shoulder motion was assessed to extrapolate relevant clinical outcomes about Total Shoulder Arthroplasty (TSA) and Reverse Total Shoulder Arthroplasty (RTSA) [6]. Patients underwent either TSA or RTSA showed shoulder ROM below 80° of elevation, indiscriminately; but, on average, patients treated with RTSA performed movements above 100° less frequently [6]. Objective measurements (i.e., mean activity value and activity frequency) of limb function after RTSA did not show significant improvements 1 year after surgery, despite DASH scores and pain perception have improved compared to preoperative outcomes [41]. In patient with neurological impairments (e.g., stroke), assessments of motor abilities performed through wearable sensors showed a time saving compared to clinical scores (e.g., Fugl-Meyer Assessment Test) measured by the clinician [50, 53]. Data from accelerometers-based systems demonstrated accurate capability in the estimation of clinical scores for quality of movement (e.g., FAS score) and in prediction of shoulder features about shoulder portion of Fugl-Meyer scale with errors near 10% [42, 49]. Generally, the main evaluated features comprise coordination, smoothness, presence of compensatory movements, speed, amplitude of ROM. Quantitative measurements, such as movement time and smoothness, showed a strong correlation with Action research arm test scores in patients after stroke [7]. Spatiotemporal parameters (e.g., ROM, movement time) extracted from inertial sensors’ data provided an accurate evaluation of patients with multiple sclerosis and they distinguished affected and unaffected upper limbs in children with hemiparesis significantly [60, 62]. Digital simulations and virtual reality implementation in upper limb rehabilitation context aim to reproduce accurately limb movements processing data from wearable sensors and give a direct feedback about the adequacy or not of the executed movements [40]. The long-term monitoring, associated with suitable feedback strategy (e.g., visive, auditory, vibrational), can foster the correction of wrong postures [40, 52]. In addition, wearable systems allows a more supervised home-rehabilitation giving substantial improvements to patient healing: total patient involvement in rehabilitation programs can advantage the motor learning process and, at the same time, providing a direct feedback (e.g., visual, auditory) about performance level can increase patient interest and motivation [44, 48]. A new trend is the use of smartphone as monitoring systems or user-interface [53, 76, 84]. Implementation of suitable application (i.e., App) can provide a direct feedback to the patients and therapists about the progress in motor performance [26]. Gathered data could be remotely evaluated by the therapists [64]. Remote monitoring can provide useful information about patients’ status at every stage of rehabilitation pathway and, at the same time, it implies a greater centralization of patients role in the management of their own health associated to a more direct clinician control [101]. A typical architecture of remote monitoring systems includes: i) wearable sensing unit to gather movements data; ii) data storage and management in cloud computing; iii) software to analyse data and extract relevant clinical parameters [58, 66]. This approach implies collection of big amounts of data regarding personal information that requires ethical considerations and the definition of legal responsibility [102]. Most of the reviewed articles limited the application of wearable systems in short-time session for shoulder motion evaluation; only few studies performed longer monitoring periods of ADLs until 7 or 11 monitoring hours of 1 day [5, 6, 34].

Conclusion

This review reveals that wearable systems are becoming an efficient and promising tool to evaluate shoulder health after neurological trauma or musculoskeletal injuries. Wearable systems have the potential to provide quantitative and meaningful clinical information about movement quality and progress in a rehabilitation pathway. The magneto-inertial measurements systems resulted the most used in clinical and research settings, followed by the growing application of smart-textiles for joint angles assessment. Despite of the accuracy of the current wearable systems in shoulder kinematics assessment, additional investigation needs to be executed to ensure long-term applicability in clinical settings and rehabilitation.
  73 in total

1.  Towards a movement quantification system capable of automatic evaluation of upper limb motor function after neurological injury.

Authors:  Virgílio F Bento; Vitor T Cruz; David D Ribeiro; João P S Cunha
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  Inertia sensor-based guidance system for upperlimb posture correction.

Authors:  Z Q Ding; Z Q Luo; A Causo; I M Chen; K X Yue; S H Yeo; K V Ling
Journal:  Med Eng Phys       Date:  2011-10-05       Impact factor: 2.242

3.  Sensor evaluation for wearable strain gauges in neurological rehabilitation.

Authors:  Toni Giorgino; Paolo Tormene; Federico Lorussi; Danilo De Rossi; Silvana Quaglini
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-04-10       Impact factor: 3.802

4.  Measurement of scapular dyskinesis using wireless inertial and magnetic sensors: Importance of scapula calibration.

Authors:  Josien C van den Noort; Suzanne H Wiertsema; Karin M C Hekman; Casper P Schönhuth; Joost Dekker; Jaap Harlaar
Journal:  J Biomech       Date:  2015-06-12       Impact factor: 2.712

5.  Shoulder physiotherapy exercise recognition: machine learning the inertial signals from a smartwatch.

Authors:  David M Burns; Nathan Leung; Michael Hardisty; Cari M Whyne; Patrick Henry; Stewart McLachlin
Journal:  Physiol Meas       Date:  2018-07-23       Impact factor: 2.833

6.  Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation.

Authors:  Carlo Massaroni; Cecilia Venanzi; Amanda P Silvatti; Daniela Lo Presti; Paola Saccomandi; Domenico Formica; Francesco Giurazza; Michele A Caponero; Emiliano Schena
Journal:  J Biophotonics       Date:  2018-02-26       Impact factor: 3.207

Review 7.  Scapular positioning and movement in unimpaired shoulders, shoulder impingement syndrome, and glenohumeral instability.

Authors:  F Struyf; J Nijs; J-P Baeyens; S Mottram; R Meeusen
Journal:  Scand J Med Sci Sports       Date:  2011-03-08       Impact factor: 4.221

Review 8.  A review of wearable sensors and systems with application in rehabilitation.

Authors:  Shyamal Patel; Hyung Park; Paolo Bonato; Leighton Chan; Mary Rodgers
Journal:  J Neuroeng Rehabil       Date:  2012-04-20       Impact factor: 4.262

9.  Development of a 3D workspace shoulder assessment tool incorporating electromyography and an inertial measurement unit-a preliminary study.

Authors:  Navid Aslani; Siamak Noroozi; Philip Davenport; Richard Hartley; Mihai Dupac; Philip Sewell
Journal:  Med Biol Eng Comput       Date:  2017-11-11       Impact factor: 2.602

10.  Wearable and implantable sensors: the patient's perspective.

Authors:  Jeroen H M Bergmann; Vikesh Chandaria; Alison McGregor
Journal:  Sensors (Basel)       Date:  2012-12-05       Impact factor: 3.576

View more
  19 in total

Review 1.  Scapulothoracic Dyskinesis: A Concept Review.

Authors:  Toufic R Jildeh; Daisy A Ference; Muhammad J Abbas; Eric X Jiang; Kelechi R Okoroha
Journal:  Curr Rev Musculoskelet Med       Date:  2021-04-06

Review 2.  Research and application advances in rehabilitation assessment of stroke.

Authors:  Kezhou Liu; Mengjie Yin; Zhengting Cai
Journal:  J Zhejiang Univ Sci B       Date:  2022-08-15       Impact factor: 5.552

3.  Differences in the Glenohumeral Joint before and after Unilateral Breast Cancer Surgery: Motion Capture Analysis.

Authors:  Silvia Beatríz García-González; María Raquel Huerta-Franco; Israel Miguel-Andrés; José de Jesús Mayagoitia-Vázquez; Miguel León-Rodríguez; Karla Barrera-Beltrán; Gilberto Espinoza-Macías
Journal:  Healthcare (Basel)       Date:  2022-04-11

4.  Scapular Dyskinesis: From Basic Science to Ultimate Treatment.

Authors:  Umile Giuseppe Longo; Laura Risi Ambrogioni; Alessandra Berton; Vincenzo Candela; Carlo Massaroni; Arianna Carnevale; Giovanna Stelitano; Emiliano Schena; Ara Nazarian; Joseph DeAngelis; Vincenzo Denaro
Journal:  Int J Environ Res Public Health       Date:  2020-04-24       Impact factor: 3.390

5.  Cost-Effectiveness of Supervised versus Unsupervised Rehabilitation for Rotator-Cuff Repair: Systematic Review and Meta-Analysis.

Authors:  Umile Giuseppe Longo; Alessandra Berton; Laura Risi Ambrogioni; Daniela Lo Presti; Arianna Carnevale; Vincenzo Candela; Giovanna Stelitano; Emiliano Schena; Ara Nazarian; Vincenzo Denaro
Journal:  Int J Environ Res Public Health       Date:  2020-04-21       Impact factor: 3.390

6.  Clinicians' perspectives on inertial measurement units in clinical practice.

Authors:  François Routhier; Noémie C Duclos; Émilie Lacroix; Josiane Lettre; Elizabeth Turcotte; Nathalie Hamel; François Michaud; Cyril Duclos; Philippe S Archambault; Laurent J Bouyer
Journal:  PLoS One       Date:  2020-11-13       Impact factor: 3.240

Review 7.  Physiological and Behavior Monitoring Systems for Smart Healthcare Environments: A Review.

Authors:  Mariana Jacob Rodrigues; Octavian Postolache; Francisco Cercas
Journal:  Sensors (Basel)       Date:  2020-04-12       Impact factor: 3.576

8.  A Multi-Parametric Wearable System to Monitor Neck Movements and Respiratory Frequency of Computer Workers.

Authors:  Daniela Lo Presti; Arianna Carnevale; Jessica D'Abbraccio; Luca Massari; Carlo Massaroni; Riccardo Sabbadini; Martina Zaltieri; Joshua Di Tocco; Marco Bravi; Sandra Miccinilli; Silvia Sterzi; Umile G Longo; Vincenzo Denaro; Michele A Caponero; Domenico Formica; Calogero M Oddo; Emiliano Schena
Journal:  Sensors (Basel)       Date:  2020-01-18       Impact factor: 3.576

9.  Efficient Upper Limb Position Estimation Based on Angular Displacement Sensors for Wearable Devices.

Authors:  Aldo-Francisco Contreras-González; Manuel Ferre; Miguel Ángel Sánchez-Urán; Francisco Javier Sáez-Sáez; Fernando Blaya Haro
Journal:  Sensors (Basel)       Date:  2020-11-12       Impact factor: 3.576

10.  A Wearable Sensor System for Physical Ergonomics Interventions Using Haptic Feedback.

Authors:  Carl Mikael Lind; Jose Antonio Diaz-Olivares; Kaj Lindecrantz; Jörgen Eklund
Journal:  Sensors (Basel)       Date:  2020-10-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.