Literature DB >> 17251049

Use of multiple wearable inertial sensors in upper limb motion tracking.

Huiyu Zhou1, Thomas Stone, Huosheng Hu, Nigel Harris.   

Abstract

This paper presents a new human motion tracking system using two wearable inertial sensors that are placed near the wrist and elbow joints of the upper limb. Each inertial sensor consists of a tri-axial accelerometer, a tri-axial gyroscope and a tri-axial magnetometer. The turning rates of the gyroscope were utilised for localising the wrist and elbow joints on the assumption that the two upper limb segment lengths are known a priori. To determine the translation and rotation of the shoulder joint, an equality-constrained optimisation technique is adopted to find an optimal solution, incorporating measurements from the tri-axial accelerometer and gyroscope. Experimental results demonstrate that this new system, compared to an optical motion tracker, has RMS position errors that are normally less than 0.01 m, and RMS angle errors that are 2.5-4.8 degrees .

Entities:  

Mesh:

Year:  2007        PMID: 17251049     DOI: 10.1016/j.medengphy.2006.11.010

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  37 in total

1.  Quadrupedal Locomotion-Respiration Entrainment and Metabolic Economy in Cross-Country Skiers.

Authors:  Kevin Boldt; Anthony Killick; Walter Herzog
Journal:  J Appl Biomech       Date:  2015-08-06       Impact factor: 1.833

2.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Andrea Giovanardi; Laura Rocchi; Angelo Davalli; Rinaldo Sacchetti
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

3.  Effect of Kayak Ergometer Elastic Tension on Upper Limb EMG Activity and 3D Kinematics.

Authors:  Neil Fleming; Bernard Donne; David Fletcher
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

4.  3D spinal motion analysis during staircase walking using an ambulatory inertial and magnetic sensing system.

Authors:  Jung Keun Lee; Edward J Park
Journal:  Med Biol Eng Comput       Date:  2011-01-27       Impact factor: 2.602

5.  Reliability and precision of 3D wireless measurement of scapular kinematics.

Authors:  Josien C van den Noort; Suzanne H Wiertsema; Karin M C Hekman; Casper P Schönhuth; Joost Dekker; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2014-09-06       Impact factor: 2.602

6.  Validation of Inertial Measurement Units for Upper Body Kinematics.

Authors:  Melissa M B Morrow; Bethany Lowndes; Emma Fortune; Kenton R Kaufman; M Susan Hallbeck
Journal:  J Appl Biomech       Date:  2017-06-26       Impact factor: 1.833

7.  An Inertial Measurement Unit-Based Wireless System for Shoulder Motion Assessment in Patients with Cervical Spinal Cord Injury: A Validation Pilot Study in a Clinical Setting.

Authors:  Riccardo Bravi; Stefano Caputo; Sara Jayousi; Alessio Martinelli; Lorenzo Biotti; Ilaria Nannini; Erez James Cohen; Eros Quarta; Stefano Grasso; Giacomo Lucchesi; Gabriele Righi; Giulio Del Popolo; Lorenzo Mucchi; Diego Minciacchi
Journal:  Sensors (Basel)       Date:  2021-02-04       Impact factor: 3.576

8.  Movement variability in stroke patients and controls performing two upper limb functional tasks: a new assessment methodology.

Authors:  Sibylle B Thies; Phil A Tresadern; Laurence P Kenney; Joel Smith; David Howard; John Y Goulermas; Christine Smith; Julie Rigby
Journal:  J Neuroeng Rehabil       Date:  2009-01-23       Impact factor: 4.262

9.  Recognizing Manual Activities Using Wearable Inertial Measurement Units: Clinical Application for Outcome Measurement.

Authors:  Ghady El Khoury; Massimo Penta; Olivier Barbier; Xavier Libouton; Jean-Louis Thonnard; Philippe Lefèvre
Journal:  Sensors (Basel)       Date:  2021-05-07       Impact factor: 3.576

10.  The use of inertial sensors system for human motion analysis.

Authors:  Antonio I Cuesta-Vargas; Alejandro Galán-Mercant; Jonathan M Williams
Journal:  Phys Ther Rev       Date:  2010-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.