Literature DB >> 1817222

Evaluation of a new reflectance pulse oximeter for clinical applications.

Y Shimada1, K Nakashima, Y Fujiwara, T Komatsu, M Kawanishi, J Takezawa, S Takatani.   

Abstract

The design of a noninvasive reflectance pulse oximeter that uses the same principle of transmittance pulse oximeter and analyses the oxygen saturation of arterial blood was described. Four sets of red and infra-red LEDs were used as light sources. The respective reflectance photoelectric outputs were used to make an internal calibration curve of the instrument relative to the arterial oxygen saturation values measured with a Co-Oximeter (OSM-3) in five healthy nonsmoking subjects during steady-state hypoxaemia. The accuracy of the present instrument was studied in six patients with respiratory failure. From 22 samples, a good correlation coefficient (0.98) with a standard deviation of 1.42 was obtained in the range between 73 and 100 per cent between the arterial oxygen saturation measured with the present instrument and that with the Co-Oximeter. The result strongly suggests the usefulness of this oximeter in monitoring patients with hypoxaemia.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1817222     DOI: 10.1007/BF02442331

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Bias and precision of pulse oximeters and arterial oximeters.

Authors:  B G Nickerson; C Sarkisian; K Tremper
Journal:  Chest       Date:  1988-03       Impact factor: 9.410

2.  Design and evaluation of a new reflectance pulse oximeter sensor.

Authors:  Y Mendelson; J C Kent; B L Yocum; M J Birle
Journal:  Med Instrum       Date:  1988-08

3.  A light emitting diode skin reflectance oximeter.

Authors:  A Cohen; N Wadsworth
Journal:  Med Biol Eng       Date:  1972-05

Review 4.  Pulse oximetry: technical aspects of machine design.

Authors:  J A Pologe
Journal:  Int Anesthesiol Clin       Date:  1987

5.  Spectrophotometric investigation of pulsatile blood flow for transcutaneous reflectance oximetry.

Authors:  Y Mendelson; P W Cheung; M R Neuman; D G Fleming; S D Cahn
Journal:  Adv Exp Med Biol       Date:  1983       Impact factor: 2.622

6.  Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter.

Authors:  Y Shimada; I Yoshiya; N Oka; K Hamaguri
Journal:  Med Biol Eng Comput       Date:  1984-09       Impact factor: 2.602

7.  A noninvasive tissue reflectance oximeter. An instrument for measurement of tissue hemoglobin oxygen saturation in vivo.

Authors:  S Takatani; P W Cheung; E A Ernst
Journal:  Ann Biomed Eng       Date:  1980       Impact factor: 3.934

8.  Spectrophotometric monitoring of arterial oxygen saturation in the fingertip.

Authors:  I Yoshiya; Y Shimada; K Tanaka
Journal:  Med Biol Eng Comput       Date:  1980-01       Impact factor: 2.602

9.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

  9 in total
  5 in total

1.  Computer analysis system of blood oxygen saturation in an animal hypoxia model.

Authors:  Y X Yang; B S Xie; Z X Zhou; J N Liu; Y Y Xue; G L Lv
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

2.  Reflectance pulse oximetry at the forehead of newborns: the influence of varying pressure on the probe.

Authors:  A C Dassel; R Graaff; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1996-11

3.  In-silico and in-vitro investigation of a photonic monitor for intestinal perfusion and oxygenation.

Authors:  Mitchell B Robinson; Ryan J Butcher; Mark A Wilson; M Nance Ericson; Gerard L Coté
Journal:  Biomed Opt Express       Date:  2017-07-19       Impact factor: 3.732

4.  Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.

Authors:  S Takatani; C Davies; N Sakakibara; A Zurick; E Kraenzler; L R Golding; G P Noon; Y Nose; M E DeBakey
Journal:  J Clin Monit       Date:  1992-10

5.  In vivo performance of a visible wavelength optical sensor for monitoring intestinal perfusion and oxygenation.

Authors:  Mitchell B Robinson; Anna M Wisniowiecki; Ryan J Butcher; Mark A Wilson; M Nance Ericson; Gerard L Cote
Journal:  J Biomed Opt       Date:  2018-05       Impact factor: 3.170

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.