Literature DB >> 31713697

Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture.

Magdy Mohamed Zaky1,2, Nabila Ali Fayed3, Mohamed Farid Shehab3.   

Abstract

PURPOSE: This study was to assess the efficiency of using a combination of one microplate and one miniplate for management of patients with parasymphyseal mandibular fractures versus two miniplates through measurement of the biting force. PATIENTS AND METHODS: The study sample consisted of sixteen patients with an isolated mandibular fracture and randomly divided into two groups; group I was managed using two miniplates, while group II was managed using a combination of one microplate at subapical region and one miniplate at the inferior border of the mandible. The biting force was measured at 1 week, 1 month, and 3 months follow-up visits. A control group consisted of 40 healthy adult volunteers was selected to measure the normal biting force.
RESULTS: The mean of the normal biting force of the control group was 435 N ± 219, 103.2 N ± 4.8, and 390.6 N ± 195.4 at right molar, incisor, and left molar regions respectively. There was a statistically non-significant difference regarding the bite force of both study groups, with a progressive increase through the different follow-up visits and a period of 3 months is sufficient for recovery of patients to regain their normal biting force.
CONCLUSION: Consequently a combination of one microplate and one miniplate is efficient for the management of isolated parasymphyseal mandibular fracture in the same way as two miniplates.

Entities:  

Keywords:  Fixation; Mandibular fracture; Microplates; Miniplates

Mesh:

Year:  2019        PMID: 31713697     DOI: 10.1007/s10006-019-00810-0

Source DB:  PubMed          Journal:  Oral Maxillofac Surg        ISSN: 1865-1550


  15 in total

1.  The use of microplates for internal fixation of mandibular fractures.

Authors:  Jin Sik Burm; Juliana E Hansen
Journal:  Plast Reconstr Surg       Date:  2010-05       Impact factor: 4.730

2.  A short period of maxillomandibular fixation for treatment of fractures of the mandibular tooth-bearing area.

Authors:  Fouad A Al-Belasy
Journal:  J Oral Maxillofac Surg       Date:  2005-07       Impact factor: 1.895

3.  Single Miniplate Fixation for Mandibular Symphysis and Parasymphysis Fracture as a Viable Alternative to Conventional Plating Based on Champy's Principles: A Prospective Comparative Clinical Study.

Authors:  Rohan Raut; R Keerthi; N Vaibhav; Abhishek Ghosh; Shashidhara Kamath Kateel
Journal:  J Maxillofac Oral Surg       Date:  2016-05-31

4.  National hardware removal rate associated with internal fixation of facial fractures.

Authors:  Jean Hanson; Scott Lovald; Ian Cowgill; Meghan Erdman; Beverly Diamond
Journal:  J Oral Maxillofac Surg       Date:  2011-01-08       Impact factor: 1.895

5.  Combination of microplate and miniplate for osteosynthesis of mandibular fractures: an experimental study.

Authors:  K U Feller; G Richter; M Schneider; U Eckelt
Journal:  Int J Oral Maxillofac Surg       Date:  2002-02       Impact factor: 2.789

6.  Bite force evaluation of mandibular fractures treated with microplates and miniplates.

Authors:  Anand Gupta; Vibha Singh; Shadab Mohammad
Journal:  J Oral Maxillofac Surg       Date:  2012-06-12       Impact factor: 1.895

Review 7.  Treatment of comminuted mandibular fractures: a critical review.

Authors:  Marcelo-Emir-Requia Abreu; Vinícius-Nery Viegas; Danilo Ibrahim; Renato Valiati; Claiton Heitz; Rogério-Miranda Pagnoncelli; Daniela-Nascimento da Silva
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2009-05-01

8.  Bite force measurement in mandibular parasymphyseal fractures: a preliminary clinical study.

Authors:  Rajesh Kshirsagar; Nitin Jaggi; Rajshekhar Halli
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2011-12

9.  A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation.

Authors:  Syed Sayeed Ahmed; Sajjad Abdur Rehman; Md Kalim Ansari; Abid Ali Khan; Omar Farooq; Arshad Hafeez Khan
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun

Review 10.  Tissue response to titanium implant using scanning electron microscope.

Authors:  Vijay P Nautiyal; Ankur Mittal; Amit Agarwal; Anupam Pandey
Journal:  Natl J Maxillofac Surg       Date:  2013-01
View more