Literature DB >> 31699530

Determining and Achieving Target Limb Length and Offset in Total Hip Arthroplasty Using Intraoperative Digital Radiography.

Eytan M Debbi1, Sean S Rajaee1, Brian F Mayeda1, Brad L Penenberg1.   

Abstract

BACKGROUND: Achieving appropriate limb length and offset in total hip arthroplasty (THA) is challenging. Target limb length and offset may not always mean equal radiographic measurements bilaterally. The goal of this study is to introduce a method for determining as well as achieving target limb length and offset using digital radiographic measurements.
METHODS: One hundred and two consecutive patients with unilateral hip osteoarthritis undergoing primary THA in the lateral decubitus position were included. Limb length and offset were measured on anterior-posterior pelvic radiographs preoperatively, intraoperatively, and postoperatively. Offset was defined as the length of a line parallel to the inter-teardrop line, extending from the edge of the ischium, at about the lower border of the ipsilateral obturator foramen, to the edge of the femoral cortex, usually at, or just below, the neck resection level. Target limb length was determined for each patient based on patient perception and severity of disease. Target offset equaled the contralateral limb. Using intraoperative digital radiography, adjustments were made until targets were achieved and the hip was stable. Patients were followed for an average of 4.2 years postoperatively.
RESULTS: Limb length was within 5 mm of target measurements in 100% of patients and offset was within 5 mm of targets in 97.1%. Target measurements differed by >5 mm from the contralateral side in 2.0% of limb length and 2.9% of offset measurements. There were no significant differences between intraoperative and postoperative limb length (P = .261) or offset (P = .747) measurements. At final follow-up, there were no dislocations or reoperations and average Hip disability and Osteoarthritis Outcome Score for Joint Replacement was 95.78.
CONCLUSION: Target limb length and offset goals can be determined for most patients undergoing THA. Targets are not always equal to the contralateral side. Intraoperative digital radiography can allow surgeons to accurately achieve target limb length and offset to within 5 mm in a homogenous cohort of patients with unilateral hip osteoarthritis with excellent clinical outcomes.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  digital radiography; intraoperative radiographic measurements; limb length; offset; total hip arthroplasty

Mesh:

Year:  2019        PMID: 31699530     DOI: 10.1016/j.arth.2019.10.003

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

2.  Compared learning curves of the direct anterior and anterolateral approach for minimally invasive hip replacement.

Authors:  Johannes C Reichert; Georgi I Wassilew; Eberhard von Rottkay; Ulrich Noeth
Journal:  Orthop Rev (Pavia)       Date:  2022-08-25

3.  [A new measurement method of offset in total hip arthroplasty].

Authors:  Wanming Qu; Hongbin Zhou; Peng Tian; Xiaorong Qin; You Zhang; Wenbin Shen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-04-15

4.  Instability Is the Most Common Indication for Revision Hip Arthroplasty in the United States: National Trends From 2012 to 2018.

Authors:  Alex Upfill-Brown; Peter P Hsiue; Troy Sekimura; Jay N Patel; Micah Adamson; Alexandra I Stavrakis
Journal:  Arthroplast Today       Date:  2021-08-31

Review 5.  The Use of Intraoperative Digital Radiography Alignment Software to Assess Implant Placement in Total Hip Arthroplasty.

Authors:  Jacob P Siebenmorgen; Benjamin M Stronach; Simon C Mears; Jeffrey B Stambough
Journal:  Curr Rev Musculoskelet Med       Date:  2021-10-25

6.  Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty.

Authors:  Tyler Thorne; Scott Nishioka; Samantha Andrews; Kristin Mathews; Cass Nakasone
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-23       Impact factor: 3.067

7.  Clinical value of digital tomographic fusion imaging in the diagnosis of avascular necrosis of the femoral head in adults.

Authors:  Jiangang Zhang; Zhuhai Wang; Ge Hong
Journal:  Ir J Med Sci       Date:  2021-11       Impact factor: 1.568

8.  A Workflow Change in Anterior Approach Total Hip Arthroplasty Leads to Improved Accuracy of Biomechanical Reconstruction Without Increased Risk of Complications.

Authors:  Stephanie V Kaszuba; Kyle M Behrens; Chad B Anderson; Alexander C Gordon
Journal:  Arthroplast Today       Date:  2021-07-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.