Literature DB >> 34694562

The Use of Intraoperative Digital Radiography Alignment Software to Assess Implant Placement in Total Hip Arthroplasty.

Jacob P Siebenmorgen1, Benjamin M Stronach1, Simon C Mears1, Jeffrey B Stambough2.   

Abstract

PURPOSE OF REVIEW: Total hip arthroplasty (THA) is a highly successful surgery with growing rates of utilization in the USA, but surgical outliers leading to postoperative complications remain a concern. There is need for a standard system of accurate, predictable intraoperative evaluation to decrease component positioning outliers. Many current intraoperative imaging systems have shown promise, but there are drawbacks that have led to slow adoption. Digital radiography, in conjunction with Radlink™ technology, is a potential solution to this problem. This review summarizes the clinical application and scientific literature regarding the use of Radlink™ in THA. RECENT
FINDINGS: Traditional surgeon-directed component placement can result in surgical outliers. This is especially true not only among low-volume arthroplasty surgeons, but can also occur with experienced, high-volume surgeons. Digital radiography allows for more precise and accurate placement of the acetabular cup in a targeted range in an effort to improve THA outcomes. Intraoperative images are obtained quickly, and they are accurate when compared to postoperative images. Additionally, the use of Radlink™ results in a significant decrease in leg length and femoral offset outliers. The adoption of Radlink™ technology in THA can significantly decrease surgical outliers, especially errors in acetabular cup placement, leg length, and femoral offset. Digital radiography avoids many of the previous aversions to intraoperative imaging as it produces a fast, reliable image with little radiation exposure and minimal interruption to workflow. There is the potential for Radlink™ use to provide superior patient outcomes, as a decrease in surgical outliers can minimize implant malpositioning with resultant need for revision THAs. Radlink™ may also provide benefit in analyzing other parameters, such as component sizing.
© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Component positioning; Digital radiography; Intraoperative imaging; Radlink; Total hip arthroplasty

Year:  2021        PMID: 34694562      PMCID: PMC8733135          DOI: 10.1007/s12178-021-09722-7

Source DB:  PubMed          Journal:  Curr Rev Musculoskelet Med        ISSN: 1935-9748


  17 in total

1.  Use of Intraoperative Computed Tomography in Craniomaxillofacial Trauma Surgery.

Authors:  Karl Cuddy; Baber Khatib; R Bryan Bell; Allen Cheng; Ashish Patel; Melissa Amundson; Eric J Dierks
Journal:  J Oral Maxillofac Surg       Date:  2017-12-13       Impact factor: 1.895

2.  Rates of Total Joint Replacement in the United States: Future Projections to 2020-2040 Using the National Inpatient Sample.

Authors:  Jasvinder A Singh; Shaohua Yu; Lang Chen; John D Cleveland
Journal:  J Rheumatol       Date:  2019-04-15       Impact factor: 4.666

Review 3.  C-arm fluoroscopy in orthopaedic surgical practice.

Authors:  Ishaq Ojodu; Ayodele Ogunsemoyin; Sascha Hopp; Tim Pohlemann; Oluwole Ige; Oluwaseun Akinola
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-23

4.  What's New in Hip Replacement.

Authors:  Mengnai Li; Andrew H Glassman
Journal:  J Bone Joint Surg Am       Date:  2018-09-19       Impact factor: 5.284

5.  Acetabular cup stiffness and implant orientation change acetabular loading patterns.

Authors:  Scott R Small; Michael E Berend; Leah A Howard; Didem Tunç; Christine A Buckley; Merrill A Ritter
Journal:  J Arthroplasty       Date:  2012-07-31       Impact factor: 4.757

6.  A Prospective, Randomized Study of Surgical Positioning Software Shows Improved Cup Placement in Total Hip Arthroplasty.

Authors:  William G Hamilton; Nancy L Parks; James F McDonald; Kiel J Pfefferle
Journal:  Orthopedics       Date:  2019-01-01       Impact factor: 1.390

7.  The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital.

Authors:  Mark C Callanan; Bryan Jarrett; Charles R Bragdon; David Zurakowski; Harry E Rubash; Andrew A Freiberg; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

8.  Total hip arthroplasty: Survival and modes of failure.

Authors:  Theofilos Karachalios; George Komnos; Antonios Koutalos
Journal:  EFORT Open Rev       Date:  2018-05-21

9.  Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

Authors:  D Hambright; M Hellman; R Barrack
Journal:  Bone Joint J       Date:  2018-01       Impact factor: 5.082

10.  Effect of hospital volume on outcomes of total hip arthroplasty: a systematic review and meta-analysis.

Authors:  Syed Hamza Mufarrih; Muhammad Owais Abdul Ghani; Russell Seth Martins; Nada Qaisar Qureshi; Sayyeda Aleena Mufarrih; Azeem Tariq Malik; Shahryar Noordin
Journal:  J Orthop Surg Res       Date:  2019-12-27       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.