| Literature DB >> 31689784 |
Qin Qin1,2,3,4, Zhengcan Wu5, Lianyun Bao1, Hui Chen1, Liping Yang3,4, Zifang He1, Zhenping Huang3,4.
Abstract
The purpose of this retrospective study was to evaluate the visual quality, objective scattering index, aberration, etc after Implantable Collamer Lens with center hole (EVO-ICL) implantation to treat patients with hypermyopia (diopter > -10 D).A total of 30 eyes underwent EVO-ICL implantation. The uncorrected distance visual acuity (UDVA), best-corrected visual acuity (BCVA), equivalent spherical degree, aberration, visual quality parameters, and corneal endothelial cell density were compared preoperative and postoperative. Fill in the National Eye Institute Refractive Error Quality of Life Instrument-42 before and after surgery.The modulation transfer function (MTF), Optical Quality Analysis System (OQAS) II values (OV 100%, 20%, 9%), and Stahl ratio 1 and 3 months after surgery were higher than the respective preoperative values. The objective scatter index value increased 1 week after surgery, but decreased 1 and 3 months after surgery compared with the preoperative values. Total aberration (TA), total low-order aberration (tLOAs), and defocus decreased at 1 week and 3 months after EVO-ICL implantation. Total high-order aberration (tHOAs) and spherical aberration were significantly increased 1 week after surgery and decreased 3 months after surgery, and the difference was statistically significant. Astigmatism, coma, and clover were not significantly different in each time period. TA, tLOAs, tHOAs, defocus, and spherical aberration were higher at 1 week than 3 months after surgery. At 3 months after surgery, the scores of the patients' NEI-RQL-42 scale were all improved except that the glare was lower than that before surgery. There was no significant difference in the density of corneal endothelial cells before and 3 months after surgery.For patients with hypermyopia, the postoperative subjective and objective visual quality of EVO-ICL implantation was better than preoperative.Entities:
Mesh:
Year: 2019 PMID: 31689784 PMCID: PMC6946539 DOI: 10.1097/MD.0000000000017677
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.817
Figure 1Optical Quality Analysis System (OQAS) II detection figure.
Preoperative demographics of the eyes undergoing EVO-ICL.
Time courses of the visual and refractive outcomes before and after EVO-ICL (−10.25 D∼−18 D) implantation.
Time courses of the optical quality parameters after EVO-ICL (−10.25 D∼−18 D).
Time courses of the aberration parameters after EVO-ICL (−10.25 D∼−18 D).
Scores of NEI-RQL-42 before and 3 mo after EVO-ICL (−10.25 D∼−18.0 D) implantation.
Comparison of corneal endothelial cell density before and after surgery.