Literature DB >> 19044229

A retrospective comparison of LASIK outcomes for myopia and myopic astigmatism with conventional NIDEK versus wavefront-guided VISX and Alcon platforms.

Paul J Dougherty1, Harkaran S Bains.   

Abstract

UNLABELLED: POSE: To compare visual, refractive, and safety outcomes among a non-wavefront scanning-slit laser (NIDEK EC-5000) and wavefront-driven lasers (Alcon CustomCornea and VISX CustomVue).
METHODS: A retrospective comparison of outcomes for 290 eyes that underwent LASIK for myopia and myopic astigmatism with either a conventional or custom ablation excimer laser system were compared. The preoperative refractive error and age of the patients were matched. Outcomes were tested for statistically significant differences among the conventional laser and each of the custom ablation lasers. A P value <.05 was considered statistically significant. Data with 3-month follow-up are reported.
RESULTS: Postoperatively, mean manifest refraction spherical equivalent was -0.12+/-0.31 diopters (D) (range: -1.50 to 0.75 D) for the NIDEK group, -0.13+/-0.39 D (range: -1.88 to 0.75 D) for the VISX group, and -0.06+/-0.26 D (range: -0.75 to 0.75 D) for the Alcon group. Eighty-nine percent of eyes in the NIDEK group, 88% of eyes in the VISX group, and 92% of eyes in the Alcon group were within a half-diopter of intended correction. None of the NIDEK and VISX eyes and 3% of Alcon eyes lost 2 or more lines of best spectacle-corrected visual acuity. No statistically significant differences in any of the outcomes studied between conventional and custom ablation treatments were noted (P>.05).
CONCLUSIONS: No statistically significant differences were observed in safety, efficacy, or predictability of eyes that underwent conventional ablation with the NIDEK EC-5000 scanning slit laser compared to custom ablation with the VISX CustomVue or Alcon CustomCornea laser systems.

Entities:  

Mesh:

Year:  2008        PMID: 19044229     DOI: 10.3928/1081597X-20081101-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  5 in total

1.  Relation of Corneal Astigmatism with Various Corneal Image Quality Parameters in a Large Cohort of Naïve Corneas.

Authors:  Mohamed Omar Yousif; Rania Serag Elkitkat; Noha Abdelsadek Alaarag; Abdelrhman Shams; Hesham Mohamed Gharieb
Journal:  Clin Ophthalmol       Date:  2020-08-04

2.  Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia.

Authors:  Zhe Yu; Jun Li; Hui Song
Journal:  BMC Ophthalmol       Date:  2020-06-17       Impact factor: 2.209

3.  Comparison of visual quality after EVO-ICL implantation and SMILE to select the appropriate surgical method for high myopia.

Authors:  Qin Qin; Lianyun Bao; Liping Yang; Zifang He; Zhenping Huang
Journal:  BMC Ophthalmol       Date:  2019-02-08       Impact factor: 2.209

4.  Evaluation of visual quality after EVO-ICL implantation for hypermyopia: An observational study.

Authors:  Qin Qin; Zhengcan Wu; Lianyun Bao; Hui Chen; Liping Yang; Zifang He; Zhenping Huang
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

5.  Comparison of outcomes of conventional WaveLight(®) Allegretto Wave(®) and Technolas(®) excimer lasers in myopic laser in situ keratomileusis.

Authors:  Daphne Cy Han; Jean Chen; Hla Myint Htoon; Donald Th Tan; Jodhbir S Mehta
Journal:  Clin Ophthalmol       Date:  2012-07-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.