| Literature DB >> 31614604 |
Hanieh Karimiyan1,2, Mohammad Reza Hadjmohammadi3, Karthik Laxman Kunjali4, Mohammad Mahdi Moein5, Joydeep Dutta6, Mohamed Abdel-Rehim7,8.
Abstract
A wooden stick coated with a novel graphene-based nanocomposite (Graphene oxide/polyethylene glycol (GO/PEG)) is introduced and investigated for its efficacy in solid phase microextraction techniques. The GO/PEG-stick was prepared and subsequently applied for the extraction of β-blockers, acebutolol, and metoprolol in human oral fluid samples, which were subsequently detected by liquid chromatography tandem mass spectrometry (LC-MS/MS). Experimental parameters affecting the extraction protocol including sample pH, extraction time, desorption time, appropriate desorption solvent, and salt addition were optimized. Method validation for the detection from oral fluid samples was performed following FDA (Food and Drug Administration) guidelines on bioanalytical method validation. Calibration curves ranging from 5.0 to 2000 nmol L-1 for acebutolol and 25.0 to 2000 nmol L-1 for metoprolol were used. The values for the coefficient of determination (R2) were found to be 0.998 and 0.996 (n = 3) for acebutolol and metoprolol, respectively. The recovery of analytes during extraction was 80.0% for acebutolol and 62.0% for metoprolol, respectively. The limit of detections (LODs) were 1.25, 8.00 nmol L-1 for acebutolol and metoprolol and the lower limit of quantifications (LLOQ) were 5.00 nmol L-1 for acebutolol and 25.0 nmol L-1 for metoprolol. Validation experiments conducted with quality control (QC) samples demonstrated method accuracy between 80.0% to 97.0% for acebutolol and from 95.0% to 109.0% for metoprolol. The inter-day precision for QC samples ranged from 3.6% to 12.9% for acebutolol and 9.5% to 11.3% for metoprolol. Additionally, the GO/PEG-stick was demonstrated to be reusable, with the same stick observed to be viable for more than 10 extractions from oral fluid samples.Entities:
Keywords: LC-MS/MS; graphene oxide/polyethylene glycol; oral fluid; wooden stick; β-blocker
Mesh:
Substances:
Year: 2019 PMID: 31614604 PMCID: PMC6832871 DOI: 10.3390/molecules24203664
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1Coated graphene oxide/polyethylene glycol (GO/PEG)-Stick.
Optimized liquid chromatography tandem mass spectrometry (LC/MS/MS) parameters for the studied analytes.
| Compound | Retention (mins ± SD) | Precursor Ion ( | Product Ion ( | Cone Energy (V) | Collision Energy (eV) |
|---|---|---|---|---|---|
|
| 6.25 ± 0.015 | 337.15 | 116.1, 141.14, | 25 | 22 |
|
| 6.38 ± 0.017 | 268.16 | 116.34, 177,33 | 30 | 20 |
|
| 8.01 ± 0.012 | 303.37 | 150.17, 154.3 | 35 | 20 |
Figure 2FT-IR spectrum of GO, GO/PEG-20000 and PEG-20000.
Figure 3The effect of adsorption time (a) and desorption time (b) on the analyte response (given as extraction recovery) sample conc. 1000 nmol L−1.
Figure 4The capacity range of GO/PEG-stick for acebutolol (a) and metoprolol (b).
Figure 5Efficiency of GO/PEG-stick compared to blank cellulose stick (1000 nmol L−1).
Accuracy and precision of the quality control (QC) samples in human saliva.
| Compounds | Samples | Accuracy (%) | Precision (RSD%) | |
|---|---|---|---|---|
| Intra-Day ( | Intra-Day ( | |||
|
|
| 97.0 | 12.3 | 12.9 |
|
| 85.0 | 3.15 | 3.6 | |
|
| 78.0 | 2.0 | 8.7 | |
|
|
| 95.0 | 10.5 | 11.3 |
|
| 101.0 | 4.7 | 9.5 | |
|
| 109.0 | 10.7 | 10.7 | |
Figure 6The chromatogram of lower limit of quantification (LLOQ) with internal standard.
Comparison of the proposed method with other extraction methods for the analysis of acebutolol and metoprolol. Microextraction by packed sorbents, MEPS; solid phase extraction, SPE; solid phase microextraction, SPME.
| Method | Ex. Sorbent | Sample Volume | Ex. Yield (%) | Accuracy (%) | Matrix | Ref. | ||
|---|---|---|---|---|---|---|---|---|
| mL | ACE | MET | ACE | MET | ||||
| LC-MS/MS | MEPS Polystyrene | 0.1 | 50 | 50 | 98–104 | 94–100 | Plasma | [ |
| 103–107 | 91–99 | Urine | ||||||
| LC-MS/MS | SPE/ion exchange | 2.0 | 84–96 | - | 84–96 | - | Plasma | [ |
| >100 | 109–124 | - | Urine | |||||
| LC-MS | In-tube SPME | 1.0 | 5.0 | 2.4 | 82–89 | 72–76 | Serum | [ |
| 88–94 | 84–85 | Urine | ||||||
| LC-MS/MS | Stick/GO/PEG | 1.0 | 80–90 | 62 | 80–97 | 95–109 | Oral fluid | Present work |