Literature DB >> 26971030

Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

Krzysztof Goryński1, Alicja Kiedrowicz2, Barbara Bojko3.   

Abstract

The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Beta-blockers; High throughput; Liquid chromatography–mass spectrometry; Plasma; SPME; Sample preparation; Solid phase microextraction; Urine

Mesh:

Substances:

Year:  2016        PMID: 26971030     DOI: 10.1016/j.jpba.2016.03.001

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Hanieh Karimiyan; Mohammad Reza Hadjmohammadi; Karthik Laxman Kunjali; Mohammad Mahdi Moein; Joydeep Dutta; Mohamed Abdel-Rehim
Journal:  Molecules       Date:  2019-10-11       Impact factor: 4.411

2.  Modifying current thin-film microextraction (TFME) solutions for analyzing prohibited substances: Evaluating new coatings using liquid chromatography.

Authors:  Łukasz Sobczak; Dominika Kołodziej; Krzysztof Goryński
Journal:  J Pharm Anal       Date:  2022-01-04

3.  Polyamide Noncoated Device for Adsorption-Based Microextraction and Novel 3D Printed Thin-Film Microextraction Supports.

Authors:  Dominika Kołodziej; Łukasz Sobczak; Krzysztof Goryński
Journal:  Anal Chem       Date:  2022-02-03       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.