Literature DB >> 28633284

Determination of Some β-Blockers and β2-Agonists in Plasma and Urine Using Liquid Chromatography-tandem Mass Spectrometry and Solid Phase Extraction.

Alaa A Salem1, Ibrahim Wasfi2, Salama S Al-Nassib1, Mahmoud Allawy Mohsin3, Nawal Al-Katheeri2.   

Abstract

A highly sensitive method for the determinations of acebutolol, clenbuterol, nadolol, oxprenolol, propranolol, terbutaline and timolol β-blockers and β2-agonists in plasma and urine was developed. The method was optimized using electrospray ionization liquid chromatography-tandem mass spectrometry (LC-ESI-MS-MS) and clean screen solid phase extraction cartridges. Matrix effect was reduced by removing co-extractives from the SPE cartridges using methanol prior to drugs' elution. Using blood and serum matrices for calibration and applying the internal standard method has also contributed to the reduction of matrix effect. Method's validation yielded linear dynamic ranges of 5.0-50.0 and 50.0-1000.0 ng/ml for drugs spiked in plasma and urine respectively. It also gave correlation coefficients of 0.94-0.99, detection limits ranged in 0.06-5.04 pg/ml and quantification limits ranged in 0.14-22.88 pg/ml for the target drugs. Developed method was successfully applied to the analysis of β-blockers and β2-agonists in plasma and urine samples. Plasma samples fortified with drugs at 7.5, 40.0 and 75.0 ng/ml gave percentage recoveries ranged in 78.66-118.10, 67.02-83.97 and 74.77-93.80, respectively. Urine samples fortified with drugs at 80.0, 400.0 and 800.0 ng/ml gave percentage recoveries ranged in 104.68-130.18, 110.23-125.16 and 109.46-116.89, respectively. Variance coefficients ranged in 0.05-0.35 and 0.04-0.12 were, respectively, obtained for the analyses of drugs in plasma and urine samples. Results suggest that developed method is well suited for the analysis of investigated drugs in biological fluids.
© The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28633284     DOI: 10.1093/chromsci/bmx045

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  2 in total

1.  Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Hanieh Karimiyan; Mohammad Reza Hadjmohammadi; Karthik Laxman Kunjali; Mohammad Mahdi Moein; Joydeep Dutta; Mohamed Abdel-Rehim
Journal:  Molecules       Date:  2019-10-11       Impact factor: 4.411

2.  Multi-functional porous organic polymers for highly-efficient solid-phase extraction of β-agonists and β-blockers in milk.

Authors:  Ci Wu; Xingshuang Ning; Xi Chen; Junfeng Ma; Qun Zhao; Li Zhao; Guozhi Zhu; Song Shi
Journal:  RSC Adv       Date:  2021-08-31       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.