Literature DB >> 15762571

Simultaneous enantioseparation and tandem UV-MS detection of eight beta-blockers in micellar electrokinetic chromatography using a chiral molecular micelle.

Cevdet Akbay1, Syed A A Rizvi, Shahab A Shamsi.   

Abstract

The feasibility of using a new and more versatile polymeric chiral surfactant, i.e., poly(sodium N-undecenoxy carbonyl-L-leucinate (poly-L-SUCL) is investigated for simultaneous enantioseparation and detection of eight structurally similar beta-blockers with tandem UV and MS detection. Three optimization approaches, i.e., direct infusion-MS, capillary zone electrophoresis-MS, and chiral micellar electrokinetic chromatography-mass spectrometry (CMEKC-MS), were investigated to optimize sheath liquid parameters, spray chamber parameters, and CMEKC separation parameters for maximum sensitivity and chiral resolution. Compared to unpolymerized micelle of L-SUCL, the use of micelle polymer (i.e., poly-L-SUCL) provided significantly higher separation efficiency, lower separation current, and higher detection sensitivity for CMEKC-ESI-MS of beta-blockers. It was also observed that, unlike monomeric L-SUCL, polymeric L-SUCL provided enantioseparation of all beta-blockers even at the lowest surfactant concentration (i.e., 5 mM poly-L-SUCL). Under optimum CMEKC and ESI-MS conditions (15 mM poly-L-SUCL, 25 mM each of NH4OAc and TEA (pH 8.0); 80% (v/v) methanol sheath liquid containing 40 mM NH4OAc (pH 8.0); sheath liquid flow rate, 5.0 microL/min; drying gas flow rate, 5 L/min; drying gas temperature, 200 degrees C; nebulizing pressure, 6 psi (0.414 bar); capillary voltage, +2.5 kV; fragmentor voltage, 85 V), baseline enantioseparation of eight beta-blockers was achieved by tandem UV (in approximately 30 min) and MS (in approximately 60 min) detection. Calibration curves for all beta-blockers were linear in the range of 0.01-0.6 mM for both CMEKC-UV and CMEKC-MS methods, but the later method provided better concentration limit of detection with similar RSD for migration time and peak areas. The CMEKC-ESI-MS method appears suitable for use as a routine procedure for high-throughput separation of beta-blockers with high sensitivity.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15762571     DOI: 10.1021/ac0401422

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  14 in total

1.  Electrophoretic extraction of low molecular weight cationic analytes from sodium dodecyl sulfate containing sample matrices for their direct electrospray ionization mass spectrometry.

Authors:  Tristan F Kinde; Thomas D Lopez; Debashis Dutta
Journal:  Anal Chem       Date:  2015-02-19       Impact factor: 6.986

2.  Establishing repeatability and ruggedness of chiral separations in micellar electrokinetic chromatography mass spectrometry: Combined use of covalently bonded capillary column and molecular micelles.

Authors:  Ferdoushi Akter; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2019-12-30       Impact factor: 4.759

3.  Development of an enantioselective assay for simultaneous separation of venlafaxine and O-desmethylvenlafaxine by micellar electrokinetic chromatography-tandem mass spectrometry: Application to the analysis of drug-drug interaction.

Authors:  Yijin Liu; Michael Jann; Chad Vandenberg; Chin B Eap; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2015-10-03       Impact factor: 4.759

4.  A high-throughput multivariate optimization for the simultaneous enantioseparation and detection of barbiturates in micellar electrokinetic chromatography-mass spectrometry.

Authors:  Bin Wang; Jun He; Shahab A Shamsi
Journal:  J Chromatogr Sci       Date:  2010-08       Impact factor: 1.618

5.  Polymeric sulfated amino acid surfactants: a class of versatile chiral selectors for micellar electrokinetic chromatography (MEKC) and MEKC-MS.

Authors:  Syed Asad Ali Rizvi; Jie Zheng; Robert P Apkarian; Steven N Dublin; Shahab A Shamsi
Journal:  Anal Chem       Date:  2007-02-01       Impact factor: 6.986

6.  Tandem laser-induced fluorescence and mass spectrometry detection for high-performance liquid chromatography analysis of the in vitro metabolism of doxorubicin.

Authors:  Joseph B Katzenmeyer; Christopher V Eddy; Edgar A Arriaga
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

7.  Chiral capillary electrophoresis-mass spectrometry of tetrahydroisoquinoline-derived neurotoxins: observation of complex stereoisomerism.

Authors:  Hao Wu; Baiqing Yuan; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2011-03-21       Impact factor: 4.759

8.  Development of a chiral micellar electrokinetic chromatography-tandem mass spectrometry assay for simultaneous analysis of warfarin and hydroxywarfarin metabolites: application to the analysis of patients serum samples.

Authors:  Xiaochun Wang; Jingguo Hou; Michael Jann; Yuen Yi Hon; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2012-11-26       Impact factor: 4.759

9.  Separation and determination of warfarin enantiomers in human plasma using a novel polymeric surfactant for micellar electrokinetic chromatography-mass spectrometry.

Authors:  Jingguo Hou; Jie Zheng; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2007-04-21       Impact factor: 4.759

10.  Multivariate approach for the enantioselective analysis in MEKC-MS: II. Optimization of 1,1'-binaphthyl-2,2'-diamine in positive ion mode.

Authors:  Jun He; Shahab A Shamsi
Journal:  J Sep Sci       Date:  2009-06       Impact factor: 3.645

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.