Literature DB >> 31571806

Prosthetists' perceptions of information obtained from a lower limb prosthesis monitoring system: a pilot study.

Geoffrey S Balkman1, Andrew C Vamos2, Joan E Sanders2, Brian G Larsen2, Brian J Hafner1.   

Abstract

INTRODUCTION: Prosthetists have limited knowledge of their patients' use of a prosthesis outside of the clinical environment. Prosthesis-mounted monitors can be used to directly measure patients' prosthesis use and activity. Prosthetists' opinions regarding potential clinical applications for sensor-based information may inform further development of this technology. A pilot study was conducted to assess prosthetists' perceptions of prosthesis use and activity information obtained by a monitoring system.
MATERIALS AND METHODS: Three local prosthetists were recruited to participate in the study. One patient with transtibial amputation from each prosthetist volunteered to wear limb presence and activity monitors for two weeks. Collected data were used to determine prosthesis use and activity. Each prosthetist completed a survey, examined clinical reports of their patient's prosthesis use and activity, and participated in a semi-structured interview. Survey results and interview transcripts were analyzed to identify and compare prosthetists' perceptions.
RESULTS: Prosthesis use and activity varied among patients. Prosthetists over- and under-estimated patient activity, relative to measurements recorded by the monitors. All three prosthetists selected multiple clinical applications for the prosthesis use and activity information in the survey, and several additional applications were suggested during the interviews. When presented with multiple report formats, prosthetists found features of each to be clinically useful.
CONCLUSIONS: Prosthesis-mounted monitors may provide prosthetists with a better understanding of their patients' prosthesis use and activity. Information provided by the monitoring system may inform clinical decisions and promote evidence-based practices.

Entities:  

Keywords:  accelerometry; ambulatory monitoring; amputation; artificial limb; instrument; sensor; walking

Year:  2019        PMID: 31571806      PMCID: PMC6768423          DOI: 10.1097/JPO.0000000000000203

Source DB:  PubMed          Journal:  J Prosthet Orthot        ISSN: 1040-8800


  25 in total

1.  Step activity monitor: long-term, continuous recording of ambulatory function.

Authors:  K L Coleman; D G Smith; D A Boone; A W Joseph; M A del Aguila
Journal:  J Rehabil Res Dev       Date:  1999-01

2.  Clinicians' views of formats of performance comparisons.

Authors:  Dominique Allwood; Zoe Hildon; Nick Black
Journal:  J Eval Clin Pract       Date:  2011-11-20       Impact factor: 2.431

3.  Considerations for developing an evidenced-based practice in orthotics and prosthetics.

Authors:  N Ramstrand; T-H Brodtkorb
Journal:  Prosthet Orthot Int       Date:  2008-03       Impact factor: 1.895

4.  Ambulation monitoring of transtibial amputation subjects with patient activity monitor versus pedometer.

Authors:  Nancy L Dudek; Omar D Khan; Edward D Lemaire; Meridith B Marks; Leyana Saville
Journal:  J Rehabil Res Dev       Date:  2008

5.  Classifying prosthetic use via accelerometry in persons with transtibial amputations.

Authors:  Morgan T Redfield; John C Cagle; Brian J Hafner; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2013

6.  Instrumented socket inserts for sensing interaction at the limb-socket interface.

Authors:  Eric C Swanson; Jake B McLean; Katheryn J Allyn; Christian B Redd; Joan E Sanders
Journal:  Med Eng Phys       Date:  2017-12-08       Impact factor: 2.242

7.  Health providers' perceptions of novel approaches to visualizing integrated health information.

Authors:  T Le; B Reeder; H Thompson; G Demiris
Journal:  Methods Inf Med       Date:  2013-02-28       Impact factor: 2.176

Review 8.  Prosthetic rehabilitation issues in the diabetic and dysvascular amputee.

Authors:  Heikki Uustal
Journal:  Phys Med Rehabil Clin N Am       Date:  2009-11       Impact factor: 1.784

9.  Validation of a patient activity monitor to quantify ambulatory activity in an amputee population.

Authors:  N Ramstrand; K-A Nilsson
Journal:  Prosthet Orthot Int       Date:  2007-06       Impact factor: 1.895

10.  A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review.

Authors:  Stéphanie A Prince; Kristi B Adamo; Meghan E Hamel; Jill Hardt; Sarah Connor Gorber; Mark Tremblay
Journal:  Int J Behav Nutr Phys Act       Date:  2008-11-06       Impact factor: 6.457

View more
  3 in total

1.  Evaluating the use of a thermoplastic socket in Kenya: A pilot study.

Authors:  Giulia Barbareschi; Wesley Teerlink; Josepg Gakunga Njuguna; Purity Musungu; Mary Dama Kirino; Catherine Holloway
Journal:  Prosthet Orthot Int       Date:  2022-03-25       Impact factor: 1.672

2.  Technology for monitoring everyday prosthesis use: a systematic review.

Authors:  Alix Chadwell; Laura Diment; M Micó-Amigo; Dafne Z Morgado Ramírez; Alex Dickinson; Malcolm Granat; Laurence Kenney; Sisary Kheng; Mohammad Sobuh; Robert Ssekitoleko; Peter Worsley
Journal:  J Neuroeng Rehabil       Date:  2020-07-14       Impact factor: 4.262

Review 3.  Reported Outcome Measures in Studies of Real-World Ambulation in People with a Lower Limb Amputation: A Scoping Review.

Authors:  Mirjam Mellema; Terje Gjøvaag
Journal:  Sensors (Basel)       Date:  2022-03-14       Impact factor: 3.576

  3 in total