Literature DB >> 23529080

GPU-based real-time volumetric ultrasound image reconstruction for a ring array.

Jung Woo Choe1, Amin Nikoozadeh, Omer Oralkan, Butrus T Khuri-Yakub.   

Abstract

Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense computational load required in synthetic beamforming. For fast imaging with a ring array, we developed graphics processing unit (GPU)-based, real-time image reconstruction software that exploits massive data-level parallelism in beamforming operations. The GPU-based software reconstructs and displays three cross-sectional images at 45 frames per second (fps). This frame rate is 4.5 times higher than that for our previously-developed multi-core CPU-based software. In an alternative imaging mode, it shows one B-mode image rotating about the axis and its maximum intensity projection, processed at a rate of 104 fps . This paper describes the image reconstruction procedure on the GPU platform and presents the experimental images obtained using this software.

Entities:  

Mesh:

Year:  2013        PMID: 23529080      PMCID: PMC4019434          DOI: 10.1109/TMI.2013.2253117

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  11 in total

1.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?

Authors:  Omer Oralkan; A Sanli Ergun; Jeremy A Johnson; Mustafa Karaman; Utkan Demirci; Kambiz Kaviani; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-11       Impact factor: 2.725

2.  Space-time encoding for high frame rate ultrasound imaging.

Authors:  Thanassis X Misaridis; Jørgen A Jensen
Journal:  Ultrasonics       Date:  2002-05       Impact factor: 2.890

3.  Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging.

Authors:  Yao Wang; Douglas N Stephens; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-12       Impact factor: 2.725

4.  Direct sampled I/Q beamforming for compact and very low-cost ultrasound imaging.

Authors:  Karthik Ranganathan; Mary K Santy; Travis N Blalock; John A Hossack; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-09       Impact factor: 2.725

5.  3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

Authors:  David T Yeh; Omer Oralkan; Ira O Wygant; Matthew O'Donnell; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

6.  Capacitive micromachined ultrasonic transducers: fabrication technology.

Authors:  Arif Sanli Ergun; Yongli Huang; Xuefeng Zhuang; Omer Oralkan; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

7.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array.

Authors:  Srikant Vaithilingam; Te-Jen Ma; Yukio Furukawa; Ira O Wygant; Xuefeng Zhuang; Adam De La Zerda; Omer Oralkan; Aya Kamaya; Sanjiv S Gambhir; R Brooke Jeffrey; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

8.  Ultrafast compound Doppler imaging: providing full blood flow characterization.

Authors:  Jeremy Bercoff; Gabriel Montaldo; Thanasis Loupas; David Savery; Fabien Mézière; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-01       Impact factor: 2.725

9.  GPU-based beamformer: fast realization of plane wave compounding and synthetic aperture imaging.

Authors:  Billy Y S Yiu; Ivan K H Tsang; Alfred C H Yu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-08       Impact factor: 2.725

10.  Volumetric real-time imaging using a CMUT ring array.

Authors:  Jung Woo Choe; Ömer Oralkan; Amin Nikoozadeh; Mustafa Gencel; Douglas N Stephens; Matthew O'Donnell; David J Sahn; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-06       Impact factor: 2.725

View more
  5 in total

1.  An FPGA-Based Backend System for Intravascular Photoacoustic and Ultrasound Imaging.

Authors:  Xun Wu; Jean L Sanders; Xiao Zhang; Feysel Yalcin Yamaner; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-14       Impact factor: 2.725

2.  Design of a Volumetric Imaging Sequence Using a Vantage-256 Ultrasound Research Platform Multiplexed With a 1024-Element Fully Sampled Matrix Array.

Authors:  Jaesok Yu; Heechul Yoon; Yousuf M Khalifa; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-19       Impact factor: 2.725

3.  Sparse matrix beamforming and image reconstruction for 2-D HIFU monitoring using harmonic motion imaging for focused ultrasound (HMIFU) with in vitro validation.

Authors:  Gary Y Hou; Jean Provost; Julien Grondin; Shutao Wang; Fabrice Marquet; Ethan Bunting; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2014-06-20       Impact factor: 10.048

4.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

Authors:  Gokce Gurun; Coskun Tekes; Jaime Zahorian; Toby Xu; Sarp Satir; Mustafa Karaman; Jennifer Hasler; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

5.  In-plane ultrasonic needle tracking using a fiber-optic hydrophone.

Authors:  Wenfeng Xia; Jean Martial Mari; Simeon J West; Yuval Ginsberg; Anna L David; Sebastien Ourselin; Adrien E Desjardins
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

  5 in total