Literature DB >> 31540557

MiniMed 670G hybrid closed loop artificial pancreas system for the treatment of type 1 diabetes mellitus: overview of its safety and efficacy.

Aria Saunders1, Laurel H Messer2, Gregory P Forlenza2.   

Abstract

Introduction: Automated insulin delivery for people with type 1 diabetes has been a major goal in the diabetes technology field for many years. While a fully automated system has not yet been accomplished, the MiniMed™ 670G artificial pancreas (AP) system is the first commercially available insulin pump that automates basal insulin delivery, while still requiring user input for insulin boluses. Determining the safety and efficacy of this system is essential to the development of future devices striving for more automation. Areas Covered: This review will provide an overview of how the MiniMed 670G system works including its safety and efficacy, how it compares to similar devices, and anticipated future advances in diabetes technology currently under development. Expert Opinion: The ultimate goal of advanced diabetes technologies is to reduce the burden and amount of management required of patients with diabetes. In addition to reducing patient workload, achieving better glucose control and improving hemoglobin A1c (HbA1c) values are essential for reducing the threat of diabetes-related complications further down the road. Current devices come close to reaching these goals, but understanding the unmet needs of patients with diabetes will allow future technologies to achieve these goals more quickly.

Entities:  

Keywords:  Artificial pancreas (AP); MiniMed 670G; automated insulin delivery; continuous glucose monitor (CGM); hybrid closed loop; insulin pump; type 1 diabetes

Year:  2019        PMID: 31540557      PMCID: PMC6816287          DOI: 10.1080/17434440.2019.1670639

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  48 in total

1.  The T1D Exchange Clinic Network and Registry: 10 Years of Enlightenment on the State of Type 1 Diabetes in the United States.

Authors:  Roy W Beck; Kellee M Miller; Nicole C Foster
Journal:  Diabetes Technol Ther       Date:  2019-06       Impact factor: 6.118

2.  Closed loop control in adolescents and children during winter sports: Use of the Tandem Control-IQ AP system.

Authors:  Laya Ekhlaspour; Gregory P Forlenza; Daniel Chernavvsky; David M Maahs; R Paul Wadwa; Mark D Deboer; Laurel H Messer; Marissa Town; Jennifer Pinnata; Geoff Kruse; Boris P Kovatchev; Bruce A Buckingham; Marc D Breton
Journal:  Pediatr Diabetes       Date:  2019-05-23       Impact factor: 4.866

3.  Effect of insulin feedback on closed-loop glucose control: a crossover study.

Authors:  Jessica L Ruiz; Jennifer L Sherr; Eda Cengiz; Lori Carria; Anirban Roy; Gayane Voskanyan; William V Tamborlane; Stuart A Weinzimer
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

4.  Automated hybrid closed-loop control with a proportional-integral-derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance.

Authors:  Trang T Ly; Stuart A Weinzimer; David M Maahs; Jennifer L Sherr; Anirban Roy; Benyamin Grosman; Martin Cantwell; Natalie Kurtz; Lori Carria; Laurel Messer; Rie von Eyben; Bruce A Buckingham
Journal:  Pediatr Diabetes       Date:  2016-05-18       Impact factor: 4.866

5.  Optimizing Hybrid Closed-Loop Therapy in Adolescents and Emerging Adults Using the MiniMed 670G System.

Authors:  Laurel H Messer; Gregory P Forlenza; Jennifer L Sherr; R Paul Wadwa; Bruce A Buckingham; Stuart A Weinzimer; David M Maahs; Robert H Slover
Journal:  Diabetes Care       Date:  2018-02-14       Impact factor: 19.112

6.  Safety and Feasibility of the OmniPod Hybrid Closed-Loop System in Adult, Adolescent, and Pediatric Patients with Type 1 Diabetes Using a Personalized Model Predictive Control Algorithm.

Authors:  Bruce A Buckingham; Gregory P Forlenza; Jordan E Pinsker; Mark P Christiansen; R Paul Wadwa; Jennifer Schneider; Thomas A Peyser; Eyal Dassau; Joon Bok Lee; Jason O'Connor; Jennifer E Layne; Trang T Ly
Journal:  Diabetes Technol Ther       Date:  2018-02-12       Impact factor: 6.118

Review 7.  Combining continuous glucose monitoring and insulin pumps to automatically tune the basal insulin infusion in diabetes therapy: a review.

Authors:  Martina Vettoretti; Andrea Facchinetti
Journal:  Biomed Eng Online       Date:  2019-03-29       Impact factor: 2.819

8.  Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes.

Authors:  Gregory P Forlenza; Orit Pinhas-Hamiel; David R Liljenquist; Dorothy I Shulman; Timothy S Bailey; Bruce W Bode; Michael A Wood; Bruce A Buckingham; Kevin B Kaiserman; John Shin; Suiying Huang; Scott W Lee; Francine R Kaufman
Journal:  Diabetes Technol Ther       Date:  2018-12-26       Impact factor: 6.118

9.  Performance of Omnipod Personalized Model Predictive Control Algorithm with Moderate Intensity Exercise in Adults with Type 1 Diabetes.

Authors:  Gregory P Forlenza; Bruce A Buckingham; Mark P Christiansen; R Paul Wadwa; Thomas A Peyser; Joon Bok Lee; Jason O'Connor; Eyal Dassau; Lauren M Huyett; Jennifer E Layne; Trang T Ly
Journal:  Diabetes Technol Ther       Date:  2019-03-29       Impact factor: 6.118

10.  Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

Authors:  Alex Zhong; Pratik Choudhary; Chantal McMahon; Pratik Agrawal; John B Welsh; Toni L Cordero; Francine R Kaufman
Journal:  Diabetes Technol Ther       Date:  2016-09-27       Impact factor: 6.118

View more
  10 in total

1.  Real-World Experience With Automated Insulin Pump Technology in Veterans With Type 1 Diabetes.

Authors:  Morolake Amole; Loren Whyte; Hans K Ghayee; Fernando Bril; Kenneth Cusi; Julio Leey-Casella
Journal:  Fed Pract       Date:  2021-11

Review 2.  Closed-Loop Artificial Pancreas Therapy for Type 1 Diabetes.

Authors:  Keren Zhou; Diana Isaacs
Journal:  Curr Cardiol Rep       Date:  2022-06-21       Impact factor: 3.955

3.  Predicting Success with a First-Generation Hybrid Closed-Loop Artificial Pancreas System Among Children, Adolescents, and Young Adults with Type 1 Diabetes: A Model Development and Validation Study.

Authors:  Gregory P Forlenza; Tim Vigers; Cari Berget; Laurel H Messer; Rayhan A Lal; Marina Basina; David M Maahs; Korey Hood; Bruce Buckingham; Darrell M Wilson; R Paul Wadwa; Kimberly A Driscoll; Laura Pyle
Journal:  Diabetes Technol Ther       Date:  2021-12-01       Impact factor: 7.337

4.  Clinical Implementation of the Omnipod 5 Automated Insulin Delivery System: Key Considerations for Training and Onboarding People With Diabetes.

Authors:  Cari Berget; Jennifer L Sherr; Daniel J DeSalvo; Ryan S Kingman; Sheri L Stone; Sue A Brown; Alex Nguyen; Leslie Barrett; Trang T Ly; Gregory P Forlenza
Journal:  Clin Diabetes       Date:  2022-04-15

5.  A qualitative study exploring the expectations of people living with type 1 diabetes regarding prospective use of a hybrid closed-loop system.

Authors:  A Quintal; V Messier; R Rabasa-Lhoret; E Racine
Journal:  Diabet Med       Date:  2020-05-13       Impact factor: 4.359

Review 6.  Therapeutic Advances in Diabetes, Autoimmune, and Neurological Diseases.

Authors:  Jinsha Liu; Joey Paolo Ting; Shams Al-Azzam; Yun Ding; Sepideh Afshar
Journal:  Int J Mol Sci       Date:  2021-03-10       Impact factor: 5.923

7.  A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes.

Authors:  Marc D Breton; Lauren G Kanapka; Roy W Beck; Laya Ekhlaspour; Gregory P Forlenza; Eda Cengiz; Melissa Schoelwer; Katrina J Ruedy; Emily Jost; Lori Carria; Emma Emory; Liana J Hsu; Mary Oliveri; Craig C Kollman; Betsy B Dokken; Stuart A Weinzimer; Mark D DeBoer; Bruce A Buckingham; Daniel Cherñavvsky; R Paul Wadwa
Journal:  N Engl J Med       Date:  2020-08-27       Impact factor: 91.245

8.  A "Slide Rule" to Adjust Insulin Dose Using Trend Arrows in Adults with Type 1 Diabetes: Test in Silico and in Real Life.

Authors:  Daniela Bruttomesso; Federico Boscari; Giuseppe Lepore; Giulia Noaro; Giacomo Cappon; Angela Girelli; Lutgarda Bozzetto; Andrea Tumminia; Giorgio Grassi; Giovanni Sparacino; Luigi Laviola; Andrea Facchinetti
Journal:  Diabetes Ther       Date:  2021-03-16       Impact factor: 2.945

9.  Phytochemical Profile, α-Glucosidase, and α-Amylase Inhibition Potential and Toxicity Evaluation of Extracts from Citrus aurantium (L) Peel, a Valuable By-Product from Northeastern Morocco.

Authors:  Ouijdane Benayad; Mohamed Bouhrim; Salima Tiji; Loubna Kharchoufa; Mohamed Addi; Samantha Drouet; Christophe Hano; Jose Manuel Lorenzo; Hasnae Bendaha; Mohamed Bnouham; Mostafa Mimouni
Journal:  Biomolecules       Date:  2021-10-20

10.  Long-term efficacy of sensor-augmented pump therapy (Minimed 640G system) combined with a telemedicine follow-up in patients with type 1 diabetes: A real life study.

Authors:  Léonie Makuété Notemi; Lamia Amoura; Fatéma Fall Mostaine; Laurent Meyer; Dominique Paris; Samy Talha; Julien Pottecher; Laurence Kessler
Journal:  J Clin Transl Endocrinol       Date:  2022-10-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.