| Literature DB >> 31531000 |
Christianne Velozo1, Diana Albuquerque1.
Abstract
The aim of this study was to undertake a literature review on the use of XP-endo Shaper (FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) for root canal preparation evaluated using microcomputed tomography (micro-CT) technology, with emphasis on the analysis of untouched canal walls. We searched the PubMed, Science Direct, SciELO, and MEDLINE databases for articles published from 2017 to 2019 using the following keywords: micro-CT, untouched walls, XP shaper, and XP endo. Articles without an abstract were excluded. Five papers were selected. Few studies on this topic are available. The studies published so far show that the XP-endo® Shaper system performs well in terms of canal preparation but leaves untouched walls.Entities:
Mesh:
Year: 2019 PMID: 31531000 PMCID: PMC6721469 DOI: 10.1155/2019/3570870
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Synthesis of the included articles on XP-endo® shaper evaluated by micro-CT.
| Author and year | Teeth | Method | Result |
|---|---|---|---|
| Azim et al. [ | 20 mandibular incisors | Evaluation of root canal preparation with the XP-endo Shaper and Vortex Blue instruments by micro-CT ( | XP-endo® Shaper had significantly less untouched walls (38.6%) compared to Vortex Blue (58.8%). However, the final preparation taper varied according to the anatomy of the treated tooth. |
| Lacerda et al. [ | 33 distal canals of mandibular molars | Evaluation of root canal preparation with the XP-endo Shaper, SAF, and TRUShape instruments by micro-CT and histologic analysis ( | There was no significant difference in the amount of unprepared surfaces between the three systems studied. The mean number of untouched areas after preparation with SAF, TRUShape, and XP-endo® Shaper was 10.92%, 17.45%, and 17.31%, respectively. Except for comparison in the apical 4 mm segments between SAF and XP-endo® Shaper, the latter showed better performance. |
| Versiani et al. [ | 30 mandibular incisors | Evaluation of root canal preparation with the XP-endo Shaper, iRace (R1, R2, and R3), and EdgeFile (X1 and X7) instruments by micro-CT ( | The XP-endo® Shaper, iRace, and EdgeFile system showed a similar shaping ability. The mean percentage of the untouched surface area was 9.42% ( |
| De-Deus et al. [ | 10 mesial canals of mandibular molars | Micro-CT analysis of the shaping ability of the XP-endo Shaper instrument as recommended by the manufacturer and then submitting each specimen to an extra activation time of 15, 30, and 45 s ( | The extra activation times of XP-endo Shaper at working length resulted in a comprehensive root canal preparation, increasing volume and surface area of the root canal and volume of removed dentin. Preparation ranging from 31.82% of untouched surface area using the time recommended by the manufacturer at working length to 29.27%, 25.0%, and 22.74% when an extra time of 15, 30, and 45 s was used at the same length, respectively. |
| Zhao et al. [ | 75 mandibular molars | Evaluation of root canal preparation with the Reciproc Blue and XP-endo Shaper instruments by micro-CT ( | The XP-endo Shaper and Reciproc Blue systems were associated with a similar area of untouched canal walls after instrumentation of C-shaped root canals, in which 30.45% and 33.04% of canal walls remained untouched, respectively ( |