Topographic correlation and asymmetry analysis of ganglion cell layer thinning and the retinal nerve fiber layer with localized visual field defects.

Alfonso Casado1, Andrea Cerveró1, Alicia López-de-Eguileta1, Raúl Fernández1, Soraya Fonseca1, Juan Carlos González1, Gema Pacheco1, Elena Gándara1, Miguel Á Gordo-Vega1.   

Abstract

PURPOSE: To evaluate the accuracy of the measurement of the ganglion cell layer (GCL) of the posterior pole analysis (PPA) software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany), the asymmetry of paired GCL sectors, the total retinal thickness asymmetry (RTA), and the peripapillary retinal nerve fiber layer (pRNFL) test to discriminate between healthy, early and advanced glaucoma eyes.
METHODS: Three hundred eighteen eyes of 161 individuals with reliable visual fields (VF) were enrolled in this study. All participants were examined using the standard posterior pole and the pRNFL protocols of the Spectralis OCT device. VF impairment was graded in hemifields, and the GCL sectors were correlated with this damage. Thicknesses of each GCL, the GCL map deviation asymmetry and the pRNFL were compared between control and glaucomatous eyes. The area under the receiver operating characteristic curve (AUC) of these analyses was assessed.
RESULTS: Fourteen of the 16 sectors of the GCL and pRNFL were significantly thinner in eyes with glaucoma than in control eyes (p<0.006). Similarly, the GCL map deviation showed a significant difference between these eyes and both the control eyes as well as the eyes with early glaucoma (p = 0.001 and p = 0.039, respectively). The highest values of AUC to diagnose both early and advanced glaucoma corresponded to the average pRNFL analysis and the GCL map deviation (AUC>0.823, p<0.040 and AUC>0.708, p<0.188, respectively).
CONCLUSIONS: Although 16 central sectors of the GCL observed with PPA showed good correlation with VF damage, the pRNFL and the GCL map deviation were more effective for discrimination of glaucomatous damage.

Entities:  

Mesh:

Year:  2019        PMID: 31509597      PMCID: PMC6738661          DOI: 10.1371/journal.pone.0222347

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Glaucoma is the principal aetiology of irreversible blindness worldwide [1]. Glaucoma is an optic neuropathy that causes optic nerve head damage and retinal ganglion cells impairment [2,3]. Using optical coherence tomography (OCT), we are able to analyse both structures by measuring the peripapillary retinal nerve fiber layer (pRNFL) as well as the ganglion cell layer (GCL) [4]. Thus, both measurements are used for clinical glaucoma assessments [5-7]. The pRNFL thickness analysis is currently the most commonly used OCT parameter [7]. However, the GCL has recently become a target for early structural glaucoma detection, as progressive GCL thinning might be an essential pathology of glaucoma [8-11]. Previous reports have shown the utility of such measurement for glaucoma diagnosis using various parameters, such as ganglion cell-inner plexiform layer (GCIPL) [12, 13]. These studies reported that the glaucoma- diagnostic performance of the GCIPL parameters was similar to that of the pRNFL parameters that have been widely applied for the diagnosis of glaucoma. In fact, other reports showed that the GCL thickness decreased earlier than the pRNFL in early glaucoma [14, 15]. The correlation between visual field (VF) damage and structural changes measured with OCT has always been a challenging task, as VF uses logarithmic data differently from OCT analyses. However, several studies have tried to correlate both tests to improve our ability to detect the presence and progression of glaucomatous damage. The results of these studies have proven there is a high interdependence between the global VF sensitivity and the pRNFL/GCL thicknesses [16-18]. However, a good correlation has not yet been proposed [19]. This correlation might be assisted by a recent update of the Spectralis OCT or the Posterior Pole Analysis (PPA) (Heidelberg Engineering, Heidelberg, Germany), which automatically delineates 61 line scans to provide 64 sectors of the measured GCL [20]. This measurement allows us to obtain a large amount of information on the GCL condition that might be used for correlation with VF, as well as to test the asymmetry between hemispheres. In fact, previous reports have stated that the analysis assessing the difference in macular total retinal thickness between retinal hemispheres might be an indicator of glaucomatous damage [21,22]. However, the asymmetry of the GCL using PPA was not previously tested and, regarding GCIPL results using OCT Cirrus [12-15], it may be useful for OCT Spectralis as well. Thus, the aims of the current study were to assess the efficacy of different GCL asymmetry analyses (GCL map deviation and 16 different sectors of GCL). In addition, we sought to perform a comparison with PPA automatic asymmetry analysis and the pRNFL to diagnose early and advanced glaucomatous impairment, as well to correlate different numeric patterns of GCL thinning with VF damage.

Methods

This prospective, cross-sectional, observational study complied with the tenets of the Declaration of Helsinki and was approved by the Ethical Committee of University Hospital Marqués de Valdecilla (UHMV). All participants were recruited from the ophthalmology department of Valdecilla Hospital from June 2016 to December 2018. Written consent forms were distributed to all the participants before the examinations. All subjects were required to have a refractive error less than -6.0 diopters of sphere or 3 diopters of cylinder, as well as less than 26 mm of axial length. Since retinal layer’s thicknesses are related with glaucoma and other various retinal pathologies, we excluded all patients with other ocular diseases (for example, diabetic retinopathy, macular degeneration, optic neuritis), clinically relevant opacities of the optic media and low- quality images due to unstable fixation, or severe cataract (patients with mild to moderate cataract could be enrolled in the study, but only high-quality images were included). Three hundred eighteen eyes from 161 patients examined in the glaucoma section were enrolled in the study (4 eyes were excluded due to low reliability of the VF).

Clinical assessment

All subjects underwent a thorough ophthalmic examination on the day of OCT imaging, including best-corrected visual acuity, refraction, intraocular pressure (IOP) measurement with GAT, slit lamp examination and fundus examination. The refractive error was recorded using an auto refractometer Canon RK-F1 (Canon USA Inc., Lake Success, NY, USA). Axial length was measured by Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland).

Optical coherence tomography procedure

Methodology for measurement of the GCL

A single, well-trained ophthalmologist (ALE) performed all the OCT examinations. The retinal thickness was measured with the Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany) using the images obtained by PPA scans. Using this protocol, the OCT instrument automatically delineates a line joining the centre of the fovea and the centre of the optic disc as a reference line. Thereafter, 61 line scans (1024 A scans/line) parallel to the central reference line were recorded. The quality of the scans was noted by a colour scale at the bottom of the scanned images. Only placement in the green range was considered to be a good quality scan for inclusion in this study. A masked investigator (SF) examined all of the images of each eye to determine whether there were any segmentations or centred errors in the images. The average retinal layers measurement of each 8x8 (3°x 3°) sector (64 sectors) was determined. Since glaucoma first damages the centre of the macula [23], only 4x4 central grids were analysed to expedite the study. These 16 sectors were numbered as shown in Fig 1, with temporal (T), nasal (N), superior (S) and inferior (I) added to ease the understanding. A superior cluster included numbered 1–8 sectors, whereas the inferior cluster included 9–16 sectors. In addition, the PPA algorithm generated the total retinal thickness asymmetry (RTA) analysis, which is an asymmetry test that automatically compares superior and inferior total retinal thicknesses. Moreover, the GCL deviation map is a colour scale representation of the topographic damage of the GCL, on which number values are assigned colours from white to blue to represent maximum or minimum GCL thicknesses, respectively. Normal values appear as red and uncoloured areas indicate an extremely lower GCL thickness. Asymmetry of the GCL and RTA was subjectively examined by a masked and experienced investigator (RF) who was blinded to glaucoma status (Fig 2).
Fig 1

OCT scan of the macula with the posterior pole analysis (PPA), showing the 16 sectors numbered from 1 to 16.

Nasal sectors included numbered NS3, NS4, NS7, NS8, NI11, NI12, NI15 and NI16 sectors; temporal sectors included TS1, TS2, TS5, TS6, TI9, TI10, TI13 and TI14; superior sectors were from 1–8, whereas inferior sectors were from 9–16.

Fig 2

Three patients with their visual fields and OCT.

Left images represent the ganglion cell layer (GCL), the centre images show peripapillary retinal nerve fiber layer (pRNFL) analysis, and the right images represent the visual fields (VF) deviation map. A: Control eye of a 40-year-old woman with non-altered GCL and pRNFL analysis as well as normal VF (A pattern); B: 72-year-old man with early glaucoma diagnosed with temporal-inferior damage of GCL associated with temporal inferior (TI) and average impairment as well as temporal superior (TS) borderline damage and VF with F pattern (nasal quadrant) in superior hemisphere; C: 78-year-old woman with advanced glaucoma and severe inferior damage of GCL analysis accompanied by temporal (TS, T, TI) and average injury of pRNFL measurement and VF with H pattern (expansive arcuate) in superior hemisphere.

OCT scan of the macula with the posterior pole analysis (PPA), showing the 16 sectors numbered from 1 to 16.

Nasal sectors included numbered NS3, NS4, NS7, NS8, NI11, NI12, NI15 and NI16 sectors; temporal sectors included TS1, TS2, TS5, TS6, TI9, TI10, TI13 and TI14; superior sectors were from 1–8, whereas inferior sectors were from 9–16.

Three patients with their visual fields and OCT.

Left images represent the ganglion cell layer (GCL), the centre images show peripapillary retinal nerve fiber layer (pRNFL) analysis, and the right images represent the visual fields (VF) deviation map. A: Control eye of a 40-year-old woman with non-altered GCL and pRNFL analysis as well as normal VF (A pattern); B: 72-year-old man with early glaucoma diagnosed with temporal-inferior damage of GCL associated with temporal inferior (TI) and average impairment as well as temporal superior (TS) borderline damage and VF with F pattern (nasal quadrant) in superior hemisphere; C: 78-year-old woman with advanced glaucoma and severe inferior damage of GCL analysis accompanied by temporal (TS, T, TI) and average injury of pRNFL measurement and VF with H pattern (expansive arcuate) in superior hemisphere. To stablish a new test of asymmetry between the GCL sectors, hemisphere comparison of clusters was assessed (TS1 vs TI13, TS2 vs TI14, TS5 vs TI9, TS6 vs TI10 and NS7 vs NI11). Circumpapillary pRNFL analysis consists of a cross-sectional imaging of the peripapillary area, and was performed using Spectralis OCT, which simultaneously captures infrared fundus and SD-OCT images at 40,000 A-scans per second. A real-time eye-tracking system measures eye movements and provides feedback to the scanning mechanism to stabilize the retinal position of the B-scan. The instrument uses 1024 A-scan points from a 3.45 mm circle centred on the optic disc. The examiner is required to manually place the scan around the optic disc. To represent data, a colour code map is generated: a green sector represents the range above the 5th percentile of the distribution in normal eyes, and is considered as “within normal limits”. A yellow sector represents the range below the 5th percentile but above the 1st percentile, and is considered as “borderline”. A red sector represents the range below the 1st percentile and is considered as “outside normal limits”. Abnormality of temporal superior (TS) and temporal inferior (TI) pRNFL was registered.

Visual field

The Swedish interactive threshold algorithm standard strategy, program 24–2 of the Humphrey Field Analyser (Carl Zeiss Meditec, Jena, Germany), was used for VF testing of each eye. Reliability criteria were fixation losses of 20% or less, false positive results of 15% or less, and false-negative results of 33% or less. The VF was classified as normal when there was a mean deviation or a pattern standard deviation within the 95th percentile, a normal glaucoma hemifield test, and the absence of a cluster of three or more non-edge points on the pattern deviation plot with a probability of occurring in <5% of the normal population, with one of these points having the probability of occurring in <1% of the normal population. The Scheie VF grading system was used to classify and grade VF impairment as showed in Fig 3 [24]. This system must also detect small changes over time, serving as an accurate proxy of glaucoma progression [23]. Classification was as follows: A: Normal VF (no defects anywhere on the field), B: Central scotoma (defect within the central 5 degrees), C: Paracentral scotoma (defects within the paracentral region that do not cross the midline), D: paracentral crescent (defects in the paracentral region that do cross the midline), E: temporal quadrant (any defect within the temporal zone), F: nasal quadrant (any defect within the nasal zone), G: peripheral arcuate (a combination of defects that must cross the midline and does not include the central two points), H: expansive arcuate (a combination of defects that must cross the midline, and includes adjoining defects in the central scotoma region, paracentral region, and temporal or nasal quadrant region), and I: altitudinal defect (all of the points above or below the horizontal meridian have a defect of <0.5%). We classified superior and inferior halves of VF and graded them from A to I. Essentially, we used F damage of VF as early glaucoma, and G, H and I as advanced glaucoma. If no damage was found in either the superior or inferior halves of the VF (A pattern), the eye was considered a control eye.
Fig 3

Grade of VF impairment used in this study.

A: Normal VF (no defects anywhere on the field), F: nasal quadrant (any defect within the nasal zone), G: peripheral arcuate (a combination of defects that must cross the midline and does not include the central two points), H: expansive arcuate (a combination of defects that must cross the midline, and includes adjoining defects in the central scotoma region, paracentral region, and temporal or nasal quadrant region), and I: altitudinal defect (all of the points above or below the horizontal meridian have a defect of <0.5%).

Grade of VF impairment used in this study.

A: Normal VF (no defects anywhere on the field), F: nasal quadrant (any defect within the nasal zone), G: peripheral arcuate (a combination of defects that must cross the midline and does not include the central two points), H: expansive arcuate (a combination of defects that must cross the midline, and includes adjoining defects in the central scotoma region, paracentral region, and temporal or nasal quadrant region), and I: altitudinal defect (all of the points above or below the horizontal meridian have a defect of <0.5%).

Statistical analysis

A 1-sample Kolmogorov-Smirnov test was used to verify the normality of the data distribution. Paired Student t-test was used to compare different sectors of the GCL and pRNFL between eyes with VF damage and control eyes. The GCL map deviation and pRNFL TS and TI affected-quadrants differences were assessed with Fisher’s test. Pearson correlation test was used to analyse the relationship between the GCL sectors and damage of the VF. A receiver operating characteristic (ROC) curve was used to assess the discrimination value of the OCT analyses. We employed area under receiver operating characteristic curves (AUCs) to assess the ability of the GCL and pRNFL thicknesses in order to discriminate glaucoma patients from healthy controls. [25]. All statistical analyses were performed using IBM SPSS Statistics V.20.0 (International Business Machine Corporation, Armonk, NY, USA). The level of statistical significance was set at P < 0.05.

Results

Overall, 318 eyes of 161 patients were included in the study. Only one eye of four patients was used due to low reliability VF indexes of the fellow eye. The mean age of the patients was 64.2 ± 12.9 years (age range: 18–88 years), and 71 patients were female (44.1%), as it is showed in . First, we classified the damage of each hemisphere (superior and inferior) of the VF using the Scheie grading system [24]. Hence, regarding inferior VF damage, 202 (63.5%) eyes presented a normal inferior hemisphere VF (A pattern), 49 (15.4%) eyes had an F pattern of VF (early glaucoma), and 116 (36.5%) eyes had an F or worse damage of VF (G, H or I patterns; early and advanced glaucoma). Similarly, concerning superior VF damage, 211 (66.4%) eyes presented a normal superior hemisphere VF 33 (10.4%) eyes had an F pattern of VF, and 107 (33.6%) eyes had an F or worse damage of VF. Using this grading system, we separately compared eyes with A pattern (control eyes) with early glaucoma and early with advanced glaucoma in each hemisphere. The results are shown in . All the sectors of the GCL were significantly thinner in eyes with any VF damage (F to I damage) than in control eyes, except NS4 and NI12 sectors, which are nasally located. Similarly, subjective asymmetry of the GCL map and pRNFL (average and temporal superior or inferior analyses) also showed significant differences between control and glaucoma eyes. However, asymmetry RTA of PPA did not show a significant difference between these eyes. Regarding the comparison between early glaucoma and control eyes, eyes with early glaucoma showed lower values of each measurement, but these differences were only significant for subjective asymmetry of the GCL in cases of inferior VF damage analysis and pRNFL TI in cases of superior VF damage. Demographic and clinical characteristics of the participants such as age, percentage of female eyes, spherical equivalent and IOP. A. (Right) Comparison of superior Ganglion Cell Layer’s (GCL) values, total retinal thickness asymmetry (RTA) analysis and Retinal Nerve Fiber Layer (RNFL) with inferior visual field degrees (VF) between control eyes (CE) and impaired VF eyes. (Left) Same comparison of superior GCL, RTA and RNFL with inferior VF between CE and early glaucoma VF eyes (F pattern VF defect). B (Right) Comparison of inferior GCL values, RTA and RNFL with superior VF degrees between CE and impaired VF eyes. (Left) Same comparison of inferior GCL, RTA and RNFL with superior VF between CE and early glaucoma VF eyes (F pattern VF defect). Data for quantitative variables are shown as the mean (standard deviation). GCL map, RTA and RNFL temporal superior (TS) or inferior (TI) affected-quadrants differences were assessed with Fisher’s test. The rest of analysis was performed using paired Student’s t-test for dependent samples. * p value is <0.05. shows the correlation between each sector of the GCL and damage of VF graded A to I. Each sector of GCL showed a significant correlation (p≤0.045) with VF damage. Subjective GCL map analysis and pRNFL (average, TS and TI) showed a significant correlation (p≤0.005). However, asymmetry RTA test of PPA did not show a significant difference. Higher R values of correlation were observed in temporal sectors of GCL (1, 5, 9 and 13, R = -0.33, -0.30, -0.32 and -0.30, respectively) as well as in average pRNFL (R<-0.30). Pearson correlation of inferior VF patterns (A to I) with different sectors of ganglion cell layer (GCL) (1–8: superior sectors and 9–16: inferior sectors), total superior and inferior GCL, GCL map deviation, total retinal thickness asymmetry (RTA) analysis and average retinal nerve fiber layer (RNFL), as well as temporal superior (TS) and inferior (TI) RNFL. A: comparison of superior GCL and RNFL with inferior VF damage. B: comparison of inferior GCL and RNFL with superior VF damage. shows AUC of ROC analysis with 95% confidence limits for sensitivity and specificity of different OCT measurements. The highest AUC values to diagnose both early and advanced glaucoma correspond to average pRNFL analysis (AUC>0.823, p<0.040). The GCL map deviation analysis also showed higher values than the RTA test. The TS1 vs TI13 and TS2 vs TI14 clusters of sectors of the GCL showed a slight improvement in AUC compared with the GCL map and pRNFL in superior early glaucoma detection (AUC >0.867, p<0.020). Area under the curve (AUC) of the receiver operating characteristic curve (ROC) analysis with 95% confidence limits for sensitivity and specificity of the difference between distinct sectors of ganglion cell layer (GCL), GCL deviation map, total retinal thickness asymmetry (RTA) analysis, retinal nerve fiber layer (RNFL) and RNFL asymmetry in the diagnosis of early glaucoma (F type of VF pattern) from control eyes (left) as well as in the diagnosis of all types of glaucoma (F-I VF patterns) (right). assessed inferior hemispheres of VF and assessed the superior hemispheres. * p value is <0.05.

Discussion

Our results showed that the values of all 16 sectors of the GCL in the centre of the macula measured with PPA are correlated with the severity of the damage of the corresponding VF, except for one nasally located sector, and that their values are different between control and damaged VF-eyes. Nevertheless, the principal objective of this study was to elaborate an asymmetry analysis of the thicknesses of the different clusters of the GC to improve previous analysis, such as the pRNFL or GCL map deviation. We found that the best analysis to diagnose both early and advanced glaucoma generally corresponds to the average pRNFL analysis. However, asymmetry tests comparing 1 vs 13 and 2 vs 14 clusters of sectors of the GCL provides better values of sensitivity and specificity than the pRNFL in early glaucoma if the VF defect starts in the superior hemisphere. This purpose was settled due to the developing concern on the importance of analysing the macula in glaucoma diagnosis and management [26]. Glaucomatous damage to the macula might occur early in the disease and can be minimized with standard VF tests [27], or even ignored [28]. Moreover, the GCL thickness analysis shows less variability and it is more useful in glaucoma diagnosis than the conventional pRNFL and optic disc parameters [29, 30]. SD OCT technology has allowed faster and better acquisition of optic nerve and retinal images than previous time-domain OCT technology [31], thereby permitting the differentiation of each retinal layer [32]. These improvements allow for the measurement of the GCL, which might be the first cells damaged in glaucoma and, therefore, the first target to diagnose early glaucoma [8–11, 14,15]. Depending on the OCT device, the strategy to assess the GCL could be diverse. The Cirrus HD-OCT (Carl Zeiss Meditec) measures the GCL together with the IPL (GCIPL), whereas the RTVue OCT (Optovue, Inc., Fremont, CA) analyses the entire ganglion cell complex (RNFL, GCL, and IPL). Most of the GCL analyses in literature have been performed using Cirrus HD-OCT [12–15, 23]. However, PPA is a relatively new software of the Spectralis OCT that allows for measurement of the GCL individually as well as all the retinal layers. This new software has been tested in previous reports [20, 33]. In this report, we focus on the analysis of PPA evaluating the asymmetry of the GCL and pRNFL, since in eyes with glaucoma, the inter-hemispheric anatomic symmetry is not preserved, which is different from healthy eyes. Thus, significant asymmetry when comparing healthy eye with eyes with glaucomatous might indicate glaucomatous damage. These asymmetry tests have been performed with Cirrus HD-OCT and have shown reliable sensitivity and specificity values (AUC>0.913) [21, 34]. Regarding PPA, this test provides an automatic asymmetry test that compares superior and inferior hemifields of the total retina thickness (RTA) of the macula. This is shown to the ophthalmologist in white to black squares in order to facilitate understanding. Um et al.[35] reported that this test has a higher sensitivity than the pRNFL in diagnosing early glaucoma, although they found no statistical differences between RTA and pRNFL when diagnosing advanced glaucoma. These authors performed five zones in the RTA map to improve the automatic report [35]. However, both Sullivan-Mee et al. [13] and Seo et al. [20] found that the pRNFL provides higher values of AUC than RTA. The authors analysed the AUC of the average, inferior and superior pRNFL as well as RTA, and found a greater AUC for the average pRNFL (0.937) and lower values for RTA (0.872) [13]. Similarly, Seo et al. found higher values of sensitivity and specificity of the pRNFL compared to RTA [20]. Interestingly, these authors performed an analysis of two to four consecutive black cells in RTA providing an AUC of 0.958. On the other hand, Yamada et al. [36] developed an interesting formula that compared superior and inferior hemifields of three different macular layers: RNFL, CGL and GCL plus IPL. The better results corresponded to GCL analysis. Hence, we believe that the GCL asymmetry test might be useful in clinical practice, and might be better than the pRNFL and RTA. First, we proved that each sector of the GCL was correlated with the severity of VF and that there were differences between control and glaucomatous eyes, which was not previously reported using Spectralis OCT and this PPA. Second, as Spectralis OCT did not provide any automated asymmetry test using the GCL, we investigated if some clusters of paired GCL sectors could be used more easily in early glaucoma detection than Yamada’s proposed formula. We found that, similar to the studies by Sullivan-Mee et al. [13] and Seo et al. [20], the AUC was greater for the pRNFL than RTA. Nevertheless, the new proposed paired-GCL test (specifically TS1 vs TI13 and TS2 vs TI14 clusters) presented similar values for detecting glaucoma and higher values of AUC for early glaucoma detection than the pRNFL but only in cases where the damage started superiorly. If the damage of the VF started inferiorly, this paired-GCL test might be accurate but the pRNFL presented higher values of AUC. Thus, in daily clinical practice, the pRNFL might remain as the best analysis to detect both early and advanced glaucoma, but the GCL asymmetry test could be used in cases of false positive pRNFL or in case of doubt. Likewise, the GCL analysis using OCT Spectralis provides a GCL map deviation. Although a normative database is not currently available for this analysis, asymmetry tests might be subjectively performed and could be easily used in clinical practice. One of the aims of this study was to determine if a masked and experienced investigator could be able to use this map to diagnose glaucomatous eyes. We found a significant correlation of this test with VF damage and its ability to differentiate glaucomatous eyes from control eyes. Moreover, we discovered that although the values of AUC were lower than the pRNFL in detecting early glaucoma cases (AUC <0.786, p>0.188), in cases of glaucoma, the AUC was comparable to the pRNFL (p>0.806, p<0.031). Thus, this map might be used in clinical practice with interesting acceptance and was reported using Cirrus HD-OCT [14, 15]. Several limitations are present in this study. First, we assumed the control eyes to be eyes with a normal visual field, but these eyes might present anatomical impairment in OCT not yet detected in VF. However, these anatomical changes might be produced up to 8 years before the changes in the VF [37], and thus we might assume this possible mistake in order to perform these transversal studies. Second, we focused on the GCL and did not use other measurements given in PPA, such as macular RNFL and macular IPL analyses. However, Yamada et al. [36] previously used these measurements with PPA and concluded that the single GCL-asymmetry test was the most accurate in detecting early glaucoma, and our aim was to propose an easy test for clinical practice. Third, we have used only the central 16 sectors of the GCL. This limitation was because the location of the large superior and inferior vessels, which are not necessarily symmetrical across the hemispheres of the retina, thereby affecting the symmetry of upper and lower GCL thicknesses [38]. Other limitations included an ethnically homogeneous (all were Caucasian) sample and the relatively small sample size. In conclusion, our findings showed that with the new Spectralis PPA, GCL segmentation might be used as a complementary and reliable marker in glaucoma assessment. Comparison of the paired GCL sectors should be used carefully; however, it might reveal early cases of glaucoma. Similarly, attention should be drawn to the GCL map, as this subjective analysis by an experienced ophthalmologist might be as useful as the GCL and pRNFL tests. However, our findings proved that the pRNFL appeared to be the most reliable test in detecting both early and advanced glaucoma.

Raw data used in the study.

This table of data represents the original values of the patients' charachteristics unprocessed. (RAR) Click here for additional data file.
Table 1

Demographic and clinical participant´s characteristics.

Overall (N = 161)
Age (years)64.2 (12.9)
Female eyes (%)71 (44.1)
Spherical equivalent (Diopters)0.77 (2.25)
IOP14.6 (2.3)

Demographic and clinical characteristics of the participants such as age, percentage of female eyes, spherical equivalent and IOP.

Table 2

Comparison between control eyes, early glaucoma and advanced glaucoma.

A Superior GCL vs inferior VFA inferior VF(N = 202)F inferior VF(N = 49)PF-I inferior VF(N = 116)P
GCL TS139.9 (7.1)38.3 (7.8)0.14935.2 (9.6)<0.001*
GCL TS247.3 (7.7)45.5 (8.3)0.15442.7 (10.1)<0.001*
GCL NS346.6 (6.9)45.6 (7.8)0.37443.5 (9.1)0.001*
GCL NS441.5 (11.6)39.1 (6.2)0.44537.5 (7.2)0.082
GCL TS542.3 (8.9)39.7 (9.9)0.08236.8 (11.6)<0.001*
GCL TS633.8 (7.6)31.9 (8.2)0.11330.3 (8.8)0.001*
GCL NS735.6 (7.6)33.7 (8.2)0.12132.7 (8.8)0.006*
GCL NS849.7 (7.2)48.2 (8.3)0.18446.6 (9.3)0.002*
Superior GC336.8 (55.4)321.9 (58.4)0.098305.3 (68.9)<0.001*
RTA61 (30.1)18 (36.7)0.45434 (29.3)0.415
GCL map (%)44 (21.8)38 (77.5)0.039*72 (62.0)0.001*
RNFL87.7 (15.4)84.1 (19.9)0.18177.7 (22.6)<0.001*
RNFL TS (%)52 (25.7)22 (44.9)0.23668 (58.6)0.004*
B Inferior GCL vs superior VFA superior VF(N = 211)F superior VF(N = 33)PF-I superior VF (N = 107)P
GCL TI945.5 (10.2)44.8 (10.4)0.27738.9 (12.9)<0.001*
GCL TI1034.5 (8.4)34.8 (7.9)0.89831.2 (8.8)0.008*
GCL NI1133.8 (8.0)34.2 (7.5)0.76430.1 (8.3)0.046*
GCL NI1249.8 (8.6)50.2 (7.9)0.41946.4 (10.2)0.066
GCL TI1339.3 (7.6)38.6 (7.9)0.30035.7 (9.5)<0.001*
GCL TI1446.2 (8.7)45.9 (8.7)0.82042.6 (10.3)<0.001*
GCL NI1546.2 (8.3)46.1 (7.9)0.39543.2 (9.7)0.011*
GCL NI1640.4 (6.7)40.3 (6.6)0.21738.5 (7.9)0.043*
Inferior GC335.8 (60.2)334.8 (57.1)0.938318.3 (112.8)0.025*
RTA130 (61.6)21 (63.6)0.66567 (62.6)0.441
GCL map (%)55 (26.1)10 (30.3)0.52761 (57.0)0.020*
RNFL88.1 (17.2)87.7 (15.5)0.43377.1 (22.7)<0.001*
RNFL TI (%)50 (23.6)17 (51.5)0.006*52 (48.6)<0.001*

A. (Right) Comparison of superior Ganglion Cell Layer’s (GCL) values, total retinal thickness asymmetry (RTA) analysis and Retinal Nerve Fiber Layer (RNFL) with inferior visual field degrees (VF) between control eyes (CE) and impaired VF eyes. (Left) Same comparison of superior GCL, RTA and RNFL with inferior VF between CE and early glaucoma VF eyes (F pattern VF defect). B (Right) Comparison of inferior GCL values, RTA and RNFL with superior VF degrees between CE and impaired VF eyes. (Left) Same comparison of inferior GCL, RTA and RNFL with superior VF between CE and early glaucoma VF eyes (F pattern VF defect). Data for quantitative variables are shown as the mean (standard deviation). GCL map, RTA and RNFL temporal superior (TS) or inferior (TI) affected-quadrants differences were assessed with Fisher’s test. The rest of analysis was performed using paired Student’s t-test for dependent samples.

* p value is <0.05.

Table 3

Correlation between each sector of GCL and damage of VF graded A to I.

AInferior VF patternBSuperior VF pattern
RPRP
GCL TS1-0.334<0.001GCL TI9-0.319<0.001
RNFL-0.311<0.001RNFL-0.303<0.001
GCL TS2-0.306<0.001GCL TI13-0.300<0.001
GCL TS5-0.3040.004GCL TI14-0.276<0.001
Superior GCL-0.291<0.001GCL NI15-0.224<0.001
GCL NS3-0.243<0.001GCL TI10-0.207<0.001
GCL TS6-0.230<0.001Inferior GCL-0.1960.001
GCL NS8-0.226<0.001GCL NI16-0.1940.001
GCL NS7-0.206<0.001GCL NI12-0.1740.003
GCL NS4-0.1170.045GCL NI11-0.1710.003
RTA0.0450.437RTA0.1030.075
RNFL TS0.2350.002GCL map0.2200.005
GCL map0.2650.001RNFL TI0.415<0.001

Pearson correlation of inferior VF patterns (A to I) with different sectors of ganglion cell layer (GCL) (1–8: superior sectors and 9–16: inferior sectors), total superior and inferior GCL, GCL map deviation, total retinal thickness asymmetry (RTA) analysis and average retinal nerve fiber layer (RNFL), as well as temporal superior (TS) and inferior (TI) RNFL. A: comparison of superior GCL and RNFL with inferior VF damage. B: comparison of inferior GCL and RNFL with superior VF damage.

Table 4

Area Under the curve (AUC) of different OCT measurements.

A VF INFERIORAUC F vs CEPA VF INFERIORAUC F-I vs CEP
RNFL0.8320.040*RNFL0.8230.022*
GCL map deviation0.7860.051GCL map deviation0.8060.030*
Difference TS5-TI9 GCL0.7670.069Difference 5–9 GCL0.7550.071
Difference TS1-TI13 GCL0.7050.162Difference TS1-TI13 GCL0.7160.125
Difference NS7-NI11 GCL0.6760.229Difference TS2-TI14 GCL0.7060.143
Difference TS2-TI14 GCL0.6480.313Difference NS7-NI11 GCL0.6710.225
RTA0.6430.329RTA0.6450.303
Difference TS6-TI10 GCL0.5760.303RNFL asymmetry0.6420.314
RNFL asymmetry0.5900.537Difference TS6-TI10 GCL0.6060.450
B VF SUPERIORAUC F vs CEPB VF SUPERIORAUC F-I vs CEP
Difference TS1-TI13 GCL0.8830.015*RNFL asymmetry0.9120.006*
Difference TS2-TI14 GCL0.8670.020*RNFL0.8880.010*
RNFL0.8250.040*Difference 5–9 GCL0.8650.015*
Difference 5–9 GCL0.7670.092Difference TS1-TI13 GCL0.8530.019*
GCL map deviation0.7080.188Difference TS2-TI14 GCL0.8240.031*
RNFL asymmetry0.6330.399GCL map deviation0.8240.031*
RTA0.6080.493Difference NS7-NI11 GCL0.5760.611
Difference TS6-TI10 GCL0.5170.916Difference TS6-TI10 GCL0.5180.906
Difference NS7-NI11 GCL0.5080.958RTA0.5120.938

Area under the curve (AUC) of the receiver operating characteristic curve (ROC) analysis with 95% confidence limits for sensitivity and specificity of the difference between distinct sectors of ganglion cell layer (GCL), GCL deviation map, total retinal thickness asymmetry (RTA) analysis, retinal nerve fiber layer (RNFL) and RNFL asymmetry in the diagnosis of early glaucoma (F type of VF pattern) from control eyes (left) as well as in the diagnosis of all types of glaucoma (F-I VF patterns) (right). assessed inferior hemispheres of VF and assessed the superior hemispheres.

* p value is <0.05.

  38 in total

1.  Automated segmentation of the macula by optical coherence tomography.

Authors:  Tapio Fabritius; Shuichi Makita; Masahiro Miura; Risto Myllylä; Yoshiaki Yasuno
Journal:  Opt Express       Date:  2009-08-31       Impact factor: 3.894

Review 2.  Spectral domain optical coherence tomography: a better OCT imaging strategy.

Authors:  Zahid Yaqoob; Jigang Wu; Changhuei Yang
Journal:  Biotechniques       Date:  2005-12       Impact factor: 1.993

3.  Structure-function relationship and diagnostic value of macular ganglion cell complex measurement using Fourier-domain OCT in glaucoma.

Authors:  Na Rae Kim; Eun Suk Lee; Gong Je Seong; Ji Hyun Kim; Hyong Gin An; Chan Yun Kim
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-04-30       Impact factor: 4.799

4.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.

Authors:  Felipe A Medeiros; Linda M Zangwill; Christopher Bowd; Roberto M Vessani; Remo Susanna; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2005-01       Impact factor: 5.258

5.  The location of the inferior and superior temporal blood vessels and interindividual variability of the retinal nerve fiber layer thickness.

Authors:  Donald C Hood; Jennifer A Salant; Stella N Arthur; Robert Ritch; Jeffrey M Liebmann
Journal:  J Glaucoma       Date:  2010-03       Impact factor: 2.503

6.  Macular segmentation with optical coherence tomography.

Authors:  Hiroshi Ishikawa; Daniel M Stein; Gadi Wollstein; Siobahn Beaton; James G Fujimoto; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-06       Impact factor: 4.799

7.  Measurement of local retinal ganglion cell layer thickness in patients with glaucoma using frequency-domain optical coherence tomography.

Authors:  Min Wang; Donald C Hood; Jung-Suk Cho; Quraish Ghadiali; Carlos Gustavo De Moraes; Gustavo V De Moraes; Xian Zhang; Robert Ritch; Jeffrey M Liebmann
Journal:  Arch Ophthalmol       Date:  2009-07

8.  Automated 3-D intraretinal layer segmentation of macular spectral-domain optical coherence tomography images.

Authors:  Mona Kathryn Garvin; Michael David Abràmoff; Xiaodong Wu; Stephen R Russell; Trudy L Burns; Milan Sonka
Journal:  IEEE Trans Med Imaging       Date:  2009-03-10       Impact factor: 10.048

9.  The number of people with glaucoma worldwide in 2010 and 2020.

Authors:  H A Quigley; A T Broman
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

10.  Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields.

Authors:  Gadi Wollstein; Joel S Schuman; Lori L Price; Ali Aydin; Siobahn A Beaton; Paul C Stark; James G Fujimoto; Hiroshi Ishikawa
Journal:  Am J Ophthalmol       Date:  2004-08       Impact factor: 5.258

View more
  5 in total

1.  Neuroprotection Against NMDA-Induced Retinal Damage by Philanthotoxin-343 Involves Reduced Nitrosative Stress.

Authors:  Mohamad Haiqal Nizar Mohamad; Izuddin Fahmy Abu; Muhammad Fattah Fazel; Renu Agarwal; Igor Iezhitsa; Norsham Juliana; Ian R Mellor; Henrik Franzyk
Journal:  Front Pharmacol       Date:  2021-12-14       Impact factor: 5.810

2.  Interocular symmetry of optical coherence tomography parameters in healthy children and adolescents.

Authors:  Mi Yeon Song; Young Hoon Hwang
Journal:  Sci Rep       Date:  2022-01-13       Impact factor: 4.379

3.  The retinal ganglion cell layer reflects neurodegenerative changes in cognitively unimpaired individuals.

Authors:  Alicia López-de-Eguileta; Sara López-García; Carmen Lage; Ana Pozueta; María García-Martínez; Martha Kazimierczak; María Bravo; Juan Irure; Marcos López-Hoyos; Pedro Muñoz-Cacho; Noelia Rodríguez-Perez; Diana Tordesillas-Gutiérrez; Alexander Goikoetxea; Claudia Nebot; Eloy Rodríguez-Rodríguez; Alfonso Casado; Pascual Sánchez-Juan
Journal:  Alzheimers Res Ther       Date:  2022-04-21       Impact factor: 8.823

Review 4.  Ganglion Cell Layer Thinning in Alzheimer's Disease.

Authors:  Alicia López-de-Eguileta; Andrea Cerveró; Ainara Ruiz de Sabando; Pascual Sánchez-Juan; Alfonso Casado
Journal:  Medicina (Kaunas)       Date:  2020-10-21       Impact factor: 2.430

5.  The Paediatric Glaucoma Diagnostic Ability of Optical Coherence Tomography: A Comparison of Macular Segmentation and Peripapillary Retinal Nerve Fibre Layer Thickness.

Authors:  Mael Lever; Christian Halfwassen; Jan Darius Unterlauft; Nikolaos E Bechrakis; Anke Manthey; Michael R R Böhm
Journal:  Biology (Basel)       Date:  2021-03-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.