Literature DB >> 31468370

A comparative study of radiation doses between phantom and patients via CT angiography of the intra-/extra-cranial, pulmonary, and abdominal/pelvic arteries.

M K A Karim1, A Sabarudin2, N A Muhammad3, K H Ng4.   

Abstract

This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.

Entities:  

Keywords:  Absorbed dose; CT angiography; Dose-length product; Effective dose; Size-specific dose estimate

Mesh:

Year:  2019        PMID: 31468370     DOI: 10.1007/s12194-019-00532-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  18 in total

1.  Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams.

Authors:  C M Ma; J P Seuntjens
Journal:  Phys Med Biol       Date:  1999-01       Impact factor: 3.609

2.  Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience.

Authors:  Vijayam K Jayakrishnan; Philip M White; Douglas Aitken; Paul Crane; Alex D McMahon; Evelyn M Teasdale
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

3.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

Review 4.  Technical approaches to the optimisation of CT.

Authors:  Willi A Kalender; Stefanie Buchenau; Paul Deak; Markus Kellermeier; Oliver Langner; Marcel van Straten; Sabrina Vollmar; Sylvia Wilharm
Journal:  Phys Med       Date:  2008-03-10       Impact factor: 2.685

5.  The effectiveness of bismuth breast shielding with protocol optimization in CT Thorax examination.

Authors:  M K A Karim; N A Rahim; K Matsubara; S Hashim; M H A Mhareb; Y Musa
Journal:  J Xray Sci Technol       Date:  2019       Impact factor: 1.535

6.  ICRP Publication 119: Compendium of dose coefficients based on ICRP Publication 60.

Authors:  K Eckerman; J Harrison; H-G Menzel; C H Clement
Journal:  Ann ICRP       Date:  2012

7.  Minimising medically unwarranted computed tomography scans.

Authors:  D J Brenner
Journal:  Ann ICRP       Date:  2012-08-22

8.  Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography.

Authors:  Azien Laqmani; Marc Regier; Simon Veldhoen; Alexandra Backhaus; Felicia Wassenberg; Susanne Sehner; Michael Groth; Hans-Dieter Nagel; Gerhard Adam; Frank O Henes
Journal:  Eur J Radiol       Date:  2014-07-08       Impact factor: 3.528

9.  Lower-dose CT urography (CTU) with iterative reconstruction technique in children - initial experience and examination protocol.

Authors:  Przemysław Bombiński; Stanisław Warchoł; Michał Brzewski; Agnieszka Biejat; Teresa Dudek-Warchoł; Grażyna Krzemień; Agnieszka Szmigielska
Journal:  Pol J Radiol       Date:  2014-06-08

10.  A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner.

Authors:  Akmal Sabarudin; Tiong Wei Siong; Ang Wee Chin; Ng Kwan Hoong; Muhammad Khalis Abdul Karim
Journal:  Sci Rep       Date:  2019-03-13       Impact factor: 4.379

View more
  2 in total

1.  Interventional Treatment of Bronchiectasis Macrosomia Based on Multirow CT Tomography Monitoring.

Authors:  DongDong Lu; Wenshu Chai; Xue Gao; Xue Yan
Journal:  J Healthc Eng       Date:  2021-12-09       Impact factor: 2.682

2.  Reproducibility and Repeatability of Coronary Computed Tomography Angiography (CCTA) Image Segmentation in Detecting Atherosclerosis: A Radiomics Study.

Authors:  Mardhiyati Mohd Yunus; Akmal Sabarudin; Muhammad Khalis Abdul Karim; Puteri N E Nohuddin; Isa Azzaki Zainal; Mohd Shahril Mohd Shamsul; Ahmad Khairuddin Mohamed Yusof
Journal:  Diagnostics (Basel)       Date:  2022-08-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.