Measurement of central augmentation index by three different methods and techniques: Agreement among Arteriograph, Complior, and Mobil-O-Graph devices.

Theodore G Papaioannou1, John Thymis1, Dimitrios Benas1, Helen Triantafyllidi1, Gavriela Kostelli1, George Pavlidis1, Fotini Kousathana1, Kostantinos Katogiannis1, Dimitrios Vlastos1, Vaia Lambadiari1, Evangelia Papadavid1, John Parissis1, Dimitrios Tousoulis1, Ignatios Ikonomidis1.   

Abstract

Wave reflection at central arteries consists of a major component of left ventricular afterload. Central augmentation index (AIx) is the most widely used surrogate of wave reflection. Recent technological developments now provide the ability to obtain, non-invasively, aortic, or carotid pressure waves and measure AIx based on various algorithms of pulse wave analysis. The aim of this study was to compare AIx measurements performed by the Arteriograph, Complior, and Mobil-O-Graph apparatuses. Recordings by each device in randomized order were performed with 5-minute interval at 211 individuals (age 55.1 ± 14.1 years, 67.8% males) who underwent diagnostic cardiovascular assessment. All measurements were obtained at the supine position, and AIx was calculated using the formula AIx = 100 × (Augmentation pressure)/(Pulse Pressure). Bland-Altman analysis was performed. Mean difference (bias) ± one standard deviation of difference (with limits of agreement) of AIx between different devices was as follows: (a) Mobil-O-Graph vs Complior: -2.1 ± 14.8% (-31.1% to 26.9%), (b) Arteriograph vs Complior: 12.9 ± 14.6% (-15.7% to 41.5%), and (c) Mobil-O-Graph vs Arteriograph: -10.8 ± 16.9% (-43.9% to 22.3%). The three examined devices exerted significant differences in central AIx estimation which makes the three devices non-interchangeable for wave reflection assessment. However, the Mobil-O-Graph device showed the highest agreement (lowest bias) with the Complior system as regards to the AIx measurement. ©2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  aorta; applanation tonometry; oscillometry; pulse wave analysis; wave reflection

Mesh:

Year:  2019        PMID: 31465154      PMCID: PMC8030305          DOI: 10.1111/jch.13654

Source DB:  PubMed          Journal:  J Clin Hypertens (Greenwich)        ISSN: 1524-6175            Impact factor:   3.738


  20 in total

Review 1.  Non-invasive methods and techniques for central blood pressure estimation: procedures, validation, reproducibility and limitations.

Authors:  Theodore G Papaioannou; Athanassios D Protogerou; Kimon S Stamatelopoulos; Manolis Vavuranakis; Christodoulos Stefanadis
Journal:  Curr Pharm Des       Date:  2009       Impact factor: 3.116

2.  Comparison of central pressure estimates obtained from SphygmoCor, Omron HEM-9000AI and carotid applanation tonometry.

Authors:  Jan G Kips; Aletta E Schutte; Sebastian J Vermeersch; Hugo W Huisman; Johannes M Van Rooyen; Matthew C Glyn; Catharina M Fourie; Leone Malan; Rudolph Schutte; Luc M Van Bortel; Patrick Segers
Journal:  J Hypertens       Date:  2011-06       Impact factor: 4.844

3.  Pulse wave analysis using the Mobil-O-Graph, Arteriograph and Complior device: a comparative study.

Authors:  Dimitrios Benas; Michalis Kornelakis; Helen Triantafyllidi; Gavriela Kostelli; George Pavlidis; Maria Varoudi; Dimitrios Vlastos; Vaia Lambadiari; John Parissis; Ignatios Ikonomidis
Journal:  Blood Press       Date:  2019-01-22       Impact factor: 2.835

4.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Validation of Central and Peripheral Non-Invasive Hemodynamic Variables Using an Oscillometric Method.

Authors:  Darío Echeverri; Alejandro Pizano; Jaime Cabrales; Karen Moreno
Journal:  High Blood Press Cardiovasc Prev       Date:  2017-10-28

7.  Aortic input impedance in normal man: relationship to pressure wave forms.

Authors:  J P Murgo; N Westerhof; J P Giolma; S A Altobelli
Journal:  Circulation       Date:  1980-07       Impact factor: 29.690

8.  Assessment of arterial stiffness in hypertension: comparison of oscillometric (Arteriograph), piezoelectronic (Complior) and tonometric (SphygmoCor) techniques.

Authors:  Noor A Jatoi; Azra Mahmud; Kathleen Bennett; John Feely
Journal:  J Hypertens       Date:  2009-11       Impact factor: 4.844

9.  Pressure wave reflection assessed from the peripheral pulse: is a transfer function necessary?

Authors:  Sandrine C Millasseau; Sundip J Patel; Simon R Redwood; James M Ritter; Philip J Chowienczyk
Journal:  Hypertension       Date:  2003-04-14       Impact factor: 10.190

10.  Comparison of Central Blood Pressure Estimated by a Cuff-Based Device With Radial Tonometry.

Authors:  Xiaoqing Peng; Martin G Schultz; Walter P Abhayaratna; Michael Stowasser; James E Sharman
Journal:  Am J Hypertens       Date:  2016-06-17       Impact factor: 2.689

View more
  6 in total

1.  Relation between Oscillometric Measurement of Central Hemodynamics and Left Ventricular Hypertrophy in Hypertensive Patients.

Authors:  Masakazu Obayashi; Shigeki Kobayashi; Takuma Nanno; Yoriomi Hamada; Masafumi Yano
Journal:  Pulse (Basel)       Date:  2021-11-30

2.  Total vascular resistance, augmentation index, and augmentation pressure increase in patients with peripheral artery disease.

Authors:  Rika Takemoto; Haruhito A Uchida; Hironobu Toda; Ken Okada; Fumio Otsuka; Hiroshi Ito; Jun Wada
Journal:  Medicine (Baltimore)       Date:  2021-08-13       Impact factor: 1.817

3.  Measurement of central augmentation index by three different methods and techniques: Agreement among Arteriograph, Complior, and Mobil-O-Graph devices.

Authors:  Theodore G Papaioannou; John Thymis; Dimitrios Benas; Helen Triantafyllidi; Gavriela Kostelli; George Pavlidis; Fotini Kousathana; Kostantinos Katogiannis; Dimitrios Vlastos; Vaia Lambadiari; Evangelia Papadavid; John Parissis; Dimitrios Tousoulis; Ignatios Ikonomidis
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-08-29       Impact factor: 3.738

4.  Associations of Sex Hormones and Hormonal Status With Arterial Stiffness in a Female Sample From Reproductive Years to Menopause.

Authors:  Eija K Laakkonen; Jari E Karppinen; Satu Lehti; Earric Lee; Emilia Pesonen; Hanna-Kaarina Juppi; Urho M Kujala; Eero A Haapala; Pauliina Aukee; Jari A Laukkanen; Johanna K Ihalainen
Journal:  Front Endocrinol (Lausanne)       Date:  2021-11-30       Impact factor: 5.555

5.  Effect of Amlodipine/Nebivolol combination therapy on central BP and PWV compared to Amlodipine/Valsartan combination therapy.

Authors:  El-Zahraa M Sultan; Hoda Rabea; Ahmed A Elberry; Hesham B Mahmoud
Journal:  Egypt Heart J       Date:  2022-03-14

6.  Pulse Wave Velocity for Risk Stratification of Patients with Aortic Aneurysm.

Authors:  Wilma Schierling; Julia Matzner; Hanna Apfelbeck; Dirk Grothues; Renate Oberhoffer-Fritz; Karin Pfister
Journal:  J Clin Med       Date:  2022-07-12       Impact factor: 4.964

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.