Probability-based 3D k-space sorting for motion robust 4D-MRI.

Duohua Sun1, Xiao Liang2, Fangfang Yin1,2,3, Jing Cai2,3,4.   

Abstract

BACKGROUND: Current 4D-MRI techniques are prone to breathing-variation-induced motion artifacts. This study developed a novel method for motion-robust multi-cycle 4D-MRI using probability-based multi-cycle sorting to overcome this deficiency.
METHODS: The main cycles were first extracted from the breathing signal. 3D k-space data were then sorted using a result-driven method for each main cycle. The new method was tested on a 4D-extended cardiac-torso (XCAT) phantom with a patient and an artificially generated breathing curve. For comparison, the k-space data were sorted using conventional phase sorting to generate single-cycle 4D-MRI images. Signal-to-noise ratio (SNR) of tumor and liver, tumor volume consistency, and average intensity projection (AIP) accuracy were compared between the two methods. The original phantom images were used as references for the evaluation.
RESULTS: The new method showed improved tumor-to-liver SNR and tumor volume consistency as compared to 3D k-space phase sorting in both the simulated artificial and real patient breathing signals. For the artificial breathing cycles, the average tumor-to-liver SNR and standard deviation (SD) of tumor volume were 2.53 and 3.80% for cycle 1, 2.24 and 6.16% for cycle 2 of probability-based sorting as compared to 1.47 and 21.83% obtained using the phase sorting method; for the patient breathing curve, values of 1.99 and 2.71%, 1.97 and 3.29%, 1.88 and 4.16% were observed for cycle 1, cycle 2 and cycle 3 of probability-based sorting, versus 1.44 and 7.20% for phase sorting method. Furthermore, the AIP accuracy was improved in the probability-based sorting approach when compared to phase sorting, with the average intensity difference per voxel reduced from 0.39 to 0.15 for the artificial curve, and from 0.46 to 0.21 for the patient curve.
CONCLUSIONS: We demonstrated the feasibility of probability-based 3D k-space sorting for motion-robust multi-cycle 4D-MRI reconstruction with breathing variation induced motion artifact reduction compared with conventional 2D image sorting and 3D phase sorting methods. This new technique can potentially improve the accuracy of radiation treatment guidance for mobile targets.

Entities:  

Keywords:  4D-MRI; Motion artifacts; extended cardiac-torso (XCAT); k-space sorting; probability-based

Year:  2019        PMID: 31448217      PMCID: PMC6685810          DOI: 10.21037/qims.2019.07.06

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  28 in total

1.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities.

Authors:  Bradley P Sutton; Douglas C Noll; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

2.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

3.  Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

Authors:  Jing Cai; Paul W Read; Talissa A Altes; Janelle A Molloy; James R Brookeman; Ke Sheng
Journal:  Phys Med Biol       Date:  2006-12-21       Impact factor: 3.609

4.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint.

Authors:  Kai Tobias Block; Martin Uecker; Jens Frahm
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

5.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

6.  Compressed sensing in dynamic MRI.

Authors:  Urs Gamper; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

7.  Model-based iterative reconstruction for radial fast spin-echo MRI.

Authors:  Kai Tobias Block; Martin Uecker; Jens Frahm
Journal:  IEEE Trans Med Imaging       Date:  2009-06-05       Impact factor: 10.048

8.  Abdominal organ motion measured using 4D CT.

Authors:  Edward D Brandner; Andrew Wu; Hungcheng Chen; Dwight Heron; Shalom Kalnicki; Krishna Komanduri; Kristina Gerszten; Steve Burton; Irfan Ahmed; Zhenyu Shou
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-06-01       Impact factor: 7.038

9.  Reproducibility of interfraction lung motion probability distribution function using dynamic MRI: statistical analysis.

Authors:  Jing Cai; Paul W Read; James M Larner; David R Jones; Stanley H Benedict; Ke Sheng
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-11-15       Impact factor: 7.038

10.  High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting.

Authors:  Peter Kellman; Christophe Chefd'hotel; Christine H Lorenz; Christine Mancini; Andrew E Arai; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.