Literature DB >> 3141490

Wound healing of skin incisions produced by ultrasonically vibrating knife, scalpel, electrosurgery, and carbon dioxide laser.

R Hambley1, P A Hebda, E Abell, B A Cohen, B V Jegasothy.   

Abstract

An ultrasonically vibrating knife has been developed for producing surgical incisions with reduced hemorrhage. Tissue injury and wound healing of porcine cutaneous incisions produced by this instrument, conventional scalpel, electrosurgery, and CO2 laser were compared regarding clinical, histopathologic, and tensile strength differences. Scalpel incisions had the least tissue injury and fastest healing, but the ultrasonically vibrating knife produced less tissue injury and faster healing than electrosurgery or CO2 laser.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3141490     DOI: 10.1111/j.1524-4725.1988.tb03478.x

Source DB:  PubMed          Journal:  J Dermatol Surg Oncol        ISSN: 0148-0812


  34 in total

1.  The mechanisms of blood vessel closure in humans by the application of ultrasonic energy.

Authors:  D Foschi; P Cellerino; F Corsi; T Taidelli; E Morandi; A Rizzi; E Trabucchi
Journal:  Surg Endosc       Date:  2002-02-08       Impact factor: 4.584

2.  Subfascial endoscopic perforator vein surgery (SEPS) using the ultrasonic scalpel.

Authors:  D W Lee; A C Chan; Y H Lam; S K Wong; E K Ng; B K Law; S C Chung
Journal:  Surg Endosc       Date:  2001-12       Impact factor: 4.584

3.  How safe is high-power ultrasonic dissection?

Authors:  Tarek A Emam; Alfred Cuschieri
Journal:  Ann Surg       Date:  2003-02       Impact factor: 12.969

4.  Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure.

Authors:  Theodore Diamantis; Michael Kontos; Antonios Arvelakis; Spiridon Syroukis; Dimitris Koronarchis; Apostolos Papalois; Emmanuel Agapitos; Elias Bastounis; Andreas C Lazaris
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

5.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) versus conventional electro surgery in post-bariatric body-contouring procedures: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Pablo Ramirez; Marc-Oliver Riener; Gabriel Djedovic; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-04-01       Impact factor: 3.315

6.  Ultrasonic versus standard electric dissection in laparoscopic colorectal surgery: a prospective randomized clinical trial.

Authors:  Mario Morino; Roberto Rimonda; Marco Ettore Allaix; Giuseppe Giraudo; Corrado Garrone
Journal:  Ann Surg       Date:  2005-12       Impact factor: 12.969

7.  A prospective observational study of 363 cases operated with three different harmonic scalpels.

Authors:  Drago Prgomet; Sasa Janjanin; Mario Bilić; Ratko Prstacić; Lana Kovac; Mihael Rudes; Vladimir Katić
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-03-24       Impact factor: 2.503

8.  Carbon dioxide laser ablation with immediate autografting in a full-thickness porcine burn model.

Authors:  R D Glatter; J S Goldberg; K T Schomacker; C C Compton; T J Flotte; D P Bua; K W Greaves; N S Nishioka; R L Sheridan
Journal:  Ann Surg       Date:  1998-08       Impact factor: 12.969

Review 9.  Laparoscopic bilateral inguinal hernia repair under local anesthesia.

Authors:  T K Pendurthi; E J DeMaria; J M Kellum
Journal:  Surg Endosc       Date:  1995-02       Impact factor: 4.584

10.  Uvulopalatopharyngoplasty with an ultrasound scalpel or laser: is there a difference?

Authors:  Perttu Reijo Juhani Halme; J Antila; H Antila; H Aho; O Polo; H Salminiitty; E Toskala
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-07-16       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.