| Literature DB >> 31399115 |
Sergiu Scobioala1, Christopher Kittel2, Khaled Elsayad2, Kai Kroeger2, Michael Oertel2, Laith Samhouri2, Uwe Haverkamp2, Hans Theodor Eich2.
Abstract
PURPOSE: Comparing radiation treatment plans by using the same safety margins and dose objectives for all techniques, to ascertain the optimal radiation technique for the stereotactic body radiotherapy (SBRT) of low-risk prostate cancer.Entities:
Keywords: Cyber knife; Dosimetric indices; Intensity-modulated radiotherapy; Normal tissue complication probability; Prostate carcinoma; Stereotactic radiotherapy
Mesh:
Year: 2019 PMID: 31399115 PMCID: PMC6689170 DOI: 10.1186/s13014-019-1353-6
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Organ at risk dose constraints
| Organ | ||
|---|---|---|
| Rectum | V18 Gy | < 50% |
| V29 Gy | < 20% | |
| V32.6 Gy | < 10% | |
| V36.25 Gy | < 5% | |
| Urinary bladder | V18 Gy | < 40% |
| V36.25 Gy | < 10% | |
| Femoral heads | V14.5 Gy | < 5% |
Abbreviations: Vx Percent of OAR volume exposed to certain radiation dose
Parameters used in the Lyman-Kutcher-Burman model
| Parameter | Rectum | Urinary bladder |
|---|---|---|
| D50% | 80 | 62 |
| α/β | 3 | 6 |
| n | 0.06 | 0.13 |
| m | 0.15 | 0.11 |
Abbreviations: D50% Tolerance dose leading to 50% complications, n Volume effect, m Steepness of the dose-response curve
Summary of dosimetric indices averaged from the treatments plans of 27 patients
| Index | HT | SW | VMAT | CK |
|---|---|---|---|---|
| Homogeneity index, HI |
| 0.21 ± 0.01 | 0.19 ± 0.01 |
|
| Conformation number, CN | 0.85 ± 0.05 | 0.81 ± 0.05 | 0.87 ± 0.03 | 0.87 ± 0.06 |
| ICRU Conformity index, CIICRU | 1.16 ± 0.08 | 1.22 ± 0.07 | 1.13 ± 0.04 | 1.08 ± 0.07 |
| Coverage index, CΔ | 0.16 ± 0.08 | 0.23 ± 0.07 | 0.14 ± 0.04 | 0.11 ± 0.06 |
| Coverage index, COV | 0.99 ± 0.01 | 0.99 ± 0.01 | 0.99 ± 0.01 | 0.97 ± 0.02 |
Abbreviations: VMAT Volumetric Modulated Arc Therapy, SW Sliding Window, HT Helical tomotherapy, CK Cyber Knife, SD Standard deviation, HI Homogeneity index, CN Conformation number, CIICRU ICRU conformity index, C∆ Coverage index, COV Coverage index COV; *-values with statistically significant difference (p < 0.05)
Averaged dosimetric values for PTV and organ at risk
| HT | SW | VMAT | CK | |
|---|---|---|---|---|
| PTV | ||||
| V80 (%) |
|
|
|
|
| D2% (Gy) | 44.10 ± 0.72 | 45.41 ± 0.69 | 45.17 ± 0.26 | 44.08 ± 0.39 |
| D98% (Gy) | 36.90 ± 0.41 | 36.86 ± 0.46 | 37.10 ± 0.27 | 35.82 ± 0.92 |
| Urinary Bladder | ||||
| V18 Gy (%) | 17.30 ± 12.88 |
|
|
|
| V36.25 Gy (%) | 3.70 ± 3.49 | 4.24 ± 4.11 | 3.98 ± 3.75 | 4.04 ± 3.82 |
| Rectum | ||||
| V18 Gy (%) |
|
|
|
|
| V29 Gy (%) |
|
|
|
|
| V32.6 Gy (%) | 0.72 ± 0.59 | 0.82 ± 0.69 | 1.29 ± 1.11 | 3.10 ± 2.24 |
| V36.25 Gy (%) | 0.01 ± 0.03 | 0.08 ± 0.11 | 1.22 ± 3.70 | 0.19 ± 0.25 |
| Femoral head right | ||||
| V14.5 Gy (%) |
| 11.21 ± 13.78 | 11.59 ± 18.60 | 2.04 ± 3.67 |
| Femoral head left | ||||
| V14.5 Gy (%) |
| 9.07 ± 11.04 | 10.16 ± 13.35 |
|
Abbreviations: HT Helical tomotherapy, SW Sliding Window, VMAT Volumetric Modulated Arc Therapy, CK Cyber Knife, PTV Planning target volume, SD standard deviation, Dx (Gy) Dose (Gy) absorbed by the certain percent (%) or absolute volume (cc) of the countered structure, Vx Percent of OAR volume exposed to certain radiation dose; *- Values with statistically significant difference (p < 0.05)
Fig. 1Boxplot demonstrating a difference in the sparing of urinary bladder and rectum by using of different radiation techniques. Red lines represent dose objective levels (level rectum V32.6 Gy < 10% out of scale). * - Significantly (p < 0.05) superior sparing for urinary bladder was found for VMAT and SW at V18 Gy vs. CK, and of rectum for Tomo, SW and VMAT at V18 Gy vs. CK. Abbreviations: VMAT – Volumetric Modulated Arc Therapy; SW – Sliding Window; HT– helical tomotherapy; CK – Cyber Knife; Vx – percent of OAR volume exposed to certain radiation dose
Fig. 2Pair-wise statistical dosimetric comparison between radiation techniques. The differences in sparing of OAR are shown at V18 Gy - V36.25 Gy for rectum and urinary bladder, and V14.5 Gy for femoral heads. Urinary bladder is indicated in yellow, rectum in brown, femoral heads in green. *- significant difference in dose distribution to OAR between radiation techniques
Calculated mean NTCP values (%) of all patients
| Technique/Organ | Rectum | Urinary bladder |
|---|---|---|
| HT | 2.3* | 2.8 |
| SW | 3.8 | 1.8 |
| VMAT | 4.5 | 2.8 |
| CK | 5.8 | 2.2 |
Abbreviations: HT Helical tomotherapy, SW Sliding Window, VMAT Volumetric Modulated Arc Therapy, CK Cyber Knife; * - value with statistically significant difference (p < 0.05)