| Literature DB >> 31333763 |
Helen A Banwell1,2, Hayley Uden2, Nicole Marshall2, Carlie Altmann2, Cylie M Williams2,3,4.
Abstract
BACKGROUND: Ankle joint range of motion is a frequently assessed measure used by health care clinicians who manage lower limb pathologies to identify ankle equinus and/or other joint motion concerns that may negatively impact on function. The purpose of this study was to assess a new iPhone application (the level function of the 'Measure application'), for measuring the weightbearing ankle lunge test in a healthy adult population (reliability) and measuring known angles (validity) when compared to a digital inclinometer.Entities:
Mesh:
Year: 2019 PMID: 31333763 PMCID: PMC6617898 DOI: 10.1186/s13047-019-0347-9
Source DB: PubMed Journal: J Foot Ankle Res ISSN: 1757-1146 Impact factor: 2.303
Fig. 1Weightbearing lunge test – knee extended position
Fig. 2Weightbearing lunge test – knee flexed position
Participant characteristics
| Characteristic | Mean (SD) | Range |
|---|---|---|
| Gender Male: Female | 13:9 | |
| Age (years) | 22.9 (1.4) | 21 to 26 |
| Height (cm) | 173.7 (9.9) | 152 to 189 |
| Weight (kgs) | 73.7 (10.9) | 48 to 90 |
Outcomes of intra-rater reliability of the iPhone level function and the digital inclinometer for the weightbearing lunge test
| Measure | Rater | Weight bearing lunge position | Mean (SD) | ICC | 95% confidence interval | SEM | MDC |
|---|---|---|---|---|---|---|---|
| Intra-rater reliability of digital inclinometer | Rater 1 | Knee extended | 29.1 (4.7) | 0.91 | 0.83, 0.96 | 1.41 | 3.91 |
| Knee flexed | 31.2 (5.1) | 0.97 | 0.97, 0.99 | 0.88 | 2.44 | ||
| Intra-rater reliability of digital inclinometer | Rater 2 | Knee extended | 30.8 (5.8) | 0.95 | 0.90, 0.98 | 1.30 | 3.60 |
| Knee flexed | 31.2 (6.0) | 0.91 | 0.81, 0.96 | 1.80 | 4.99 | ||
| Intra-rater reliability of iPhone level function | Rater 1 | Knee extended | 30.0 (4.7) | 0.85 | 0.71, 0.93 | 1.82 | 5.04 |
| Knee flexed | 30.3 (5.2) | 0.95 | 0.90, 0.98 | 1.16 | 3.22 | ||
| Intra-rater reliability of iPhone level function | Rater 2 | Knee extended | 27.0 (4.2) | 0.85 | 0.71, 0.93 | 1.63 | 4.52 |
| Knee flexed | 30.2 (4.9) | 0.95 | 0.90. 0.98 | 1.10 | 3.05 |
ICC intraclass coefficient, SEM standard error of measurement, MDC Minimal detectable change
Outcomes of inter-rater reliability of the iPhone level function and the digital inclinometer for the weightbearing lunge test
| Measure | Weight bearing lunge position | Mean (SD) | Combined mean (SD) | SEM | ICC | 95% confidence interval |
|---|---|---|---|---|---|---|
| Inter-rater reliability of digital inclinometer between raters | Knee extended | 29.1(4.9) | 1.88 | 0.85 | 0.59, 0.93 | |
| Knee flexed | 31.42 (5.5) | 1.10 | 0.96 | 0.91, 0.98 | ||
| Inter-rater reliability of iPhone level function between raters | Knee extended | 27.7 (5.0) | 1.22 | 0.94 | 0.90, 0.97 | |
| Knee flexed | 30.4 (4.4) | 0.62 | 0.98 | 0.96. 0.99 |
Fig. 3Bland Altman plot of concurrent validity outcomes