Literature DB >> 25704110

Reliability and minimal detectable change of the weight-bearing lunge test: A systematic review.

Cameron J Powden1, Johanna M Hoch2, Matthew C Hoch3.   

Abstract

Ankle dorsiflexion range of motion (DROM) is often a point of emphasis during the rehabilitation of lower extremity pathologies. With the growing popularity of weight-bearing DROM assessments, several versions of the weight-bearing lunge (WBLT) test have been developed and numerous reliability studies have been conducted. The purpose of this systematic review was to critically appraise and synthesize the studies which examined the reliability and responsiveness of the WBLT to assess DROM. A systematic search of PubMed and EBSCO Host databases from inception to September 2014 was conducted to identify studies whose primary aim was assessing the reliability of the WBLT. The Quality Appraisal of Reliability Studies assessment tool was utilized to determine the quality of included studies. Relative reliability was examined through intraclass correlation coefficients (ICC) and responsiveness was evaluated through minimal detectable change (MDC). A total of 12 studies met the eligibility criteria and were included. Nine included studies assessed inter-clinician reliability and 12 included studies assessed intra-clinician reliability. There was strong evidence that inter-clinician reliability (ICC = 0.80-0.99) as well as intra-clinician reliability (ICC = 0.65-0.99) of the WBLT is good. Additionally, average MDC scores of 4.6° or 1.6 cm for inter-clinician and 4.7° or 1.9 cm for intra-clinician were found, indicating the minimal change in DROM needed to be outside the error of the WBLT. This systematic review determined that the WBLT, regardless of method, can be used clinically to assess DROM as it provides consistent results between one or more clinicians and demonstrates reasonable responsiveness.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Keywords:  Ankle; Assessment; Dorsiflexion; Range of motion; Repeatability

Mesh:

Year:  2015        PMID: 25704110     DOI: 10.1016/j.math.2015.01.004

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  24 in total

1.  Use of Social or Behavioral Theories in Exercise-Related Injury Prevention Program Research: A Systematic Review.

Authors:  Emily H Gabriel; Ryan S McCann; Matthew C Hoch
Journal:  Sports Med       Date:  2019-10       Impact factor: 11.136

2.  A 4-Week Multimodal Intervention for Individuals With Chronic Ankle Instability: Examination of Disease-Oriented and Patient-Oriented Outcomes.

Authors:  Cameron J Powden; Johanna M Hoch; Beth E Jamali; Matthew C Hoch
Journal:  J Athl Train       Date:  2018-12-27       Impact factor: 2.860

3.  Inferior tibiofibular joint mobilization with movement and taping does not improve chronic ankle dorsiflexion stiffness: a randomized placebo-controlled trial.

Authors:  Anh Phong Nguyen; Phillipe Mahaudens; Christine Detrembleur; Toby Hall; Benjamin Hidalgo
Journal:  J Man Manip Ther       Date:  2020-08-18

4.  MANAGEMENT OF ACUTE GRADE II LATERAL ANKLE SPRAINS WITH AN EMPHASIS ON LIGAMENT PROTECTION: A DESCRIPTIVE CASE SERIES.

Authors:  Bradley Wells; Chris Allen; Gail Deyle; Theodore Croy
Journal:  Int J Sports Phys Ther       Date:  2019-06

5.  Effects of Mulligan Mobilization with Movement in Subacute Lateral Ankle Sprains: A Pragmatic Randomized Trial.

Authors:  Anh Phong Nguyen; Laurent Pitance; Philippe Mahaudens; Christine Detrembleur; Yuval David; Toby Hall; Benjamin Hidalgo
Journal:  J Man Manip Ther       Date:  2021-02-26

6.  Evaluating the Clinical Tests for Adolescent Tibial Bone Stress Injuries.

Authors:  Eric D Nussbaum; Charles J Gatt; Jaynie Bjornarra; Chenyun Yang
Journal:  Sports Health       Date:  2021-02-12       Impact factor: 3.843

7.  Weight bearing versus non-weight bearing ankle dorsiflexion measurement in people with diabetes: a cross sectional study.

Authors:  A Searle; M J Spink; V H Chuter
Journal:  BMC Musculoskelet Disord       Date:  2018-06-02       Impact factor: 2.362

8.  The iPhone Measure app level function as a measuring device for the weight bearing lunge test in adults: a reliability study.

Authors:  Helen A Banwell; Hayley Uden; Nicole Marshall; Carlie Altmann; Cylie M Williams
Journal:  J Foot Ankle Res       Date:  2019-07-09       Impact factor: 2.303

9.  WITHIN-SESSION RELIABILITY FOR INTER-LIMB ASYMMETRIES IN ANKLE DORSIFLEXION RANGE OF MOTION MEASURED DURING THE WEIGHT-BEARING LUNGE TEST.

Authors:  Louis P Howe; Theodoros M Bampouras; Jamie S North; Mark Waldron
Journal:  Int J Sports Phys Ther       Date:  2020-02

10.  A randomised cross over study to evaluate the performance of a novel ankle dorsiflexion measurement device for novice users.

Authors:  Peter R Worsley; Caitlan Conington; Holly Stuart; Alice Patterson; Dan L Bader
Journal:  J Foot Ankle Res       Date:  2018-07-31       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.