MR safety assessment of active implantable medical devices.

Sarra Aissani1, Elmar Laistler2,3, Jacques Felblinger4,5.   

Abstract

BACKGROUND: Increasing numbers of patients with active implantable medical devices (AIMDs) require magnetic resonance (MR) examinations. The manufacturers are continuing to improve the MR compatibility of their AIMDs. To this end, a variety of measurement methods and numerical simulations are used to evaluate the risks associated with magnetic resonance imaging (MRI).
OBJECTIVE: In this article, test methods used to investigate interactions between AIMDs with radio frequency fields and time-varying magnetic gradient fields are reviewed.
MATERIALS AND METHODS: A literature review of known test methods for radio frequency and gradient field exposure of AIMDs with leads, in particular for neurostimulators, cochlear implants, and implanted infusion pumps, is presented. The state of the art and promising methods are discussed.
RESULTS: ISO/TS 10974 describes the design of high frequency and gradient injection setups to test conductive materials. A large number of sensor designs have been published to measure the induced voltages and currents through radio frequency and gradient fields and for monitoring AIMDs during MR examinations in in vitro tests.
CONCLUSION: The test methods should be planned to be as conservative as possible to cover the worst case scenario. However, in vitro measurements and computer simulation are far from being able to cover all possible configurations in their complexity and uniqueness. For safer MR examinations, current research recommends in vivo testing prior to MR, parallel radiofrequency transmission techniques, and new sequences with reduced energy input in the presence of AIMDs.

Entities:  

Keywords:  Compatibility; Heating; Magnetic resonance imaging; Malfunction; Rectification

Mesh:

Year:  2019        PMID: 31321466     DOI: 10.1007/s00117-019-0541-6

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  19 in total

1.  Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment.

Authors:  Harikrishna Tandri; Menekhem M Zviman; Steven R Wedan; Thomas Lloyd; Ronald D Berger; Henry Halperin
Journal:  Heart Rhythm       Date:  2007-12-27       Impact factor: 6.343

2.  Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads.

Authors:  Peter Nordbeck; Ingo Weiss; Philipp Ehses; Oliver Ritter; Marcus Warmuth; Florian Fidler; Volker Herold; Peter M Jakob; Mark E Ladd; Harald H Quick; Wolfgang R Bauer
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

3.  Experimental setup for transfer function measurement to assess RF heating of medical leads in MRI: Validation in the case of a single wire.

Authors:  Alexia Missoffe; Sarra Aissani
Journal:  Magn Reson Med       Date:  2017-06-06       Impact factor: 4.668

4.  Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners.

Authors:  Eugenia Cabot; Tom Lloyd; Andreas Christ; Wolfgang Kainz; Mark Douglas; Gregg Stenzel; Steve Wedan; Niels Kuster
Journal:  Bioelectromagnetics       Date:  2012-10-11       Impact factor: 2.010

5.  An RF-induced voltage sensor for investigating pacemaker safety in MRI.

Authors:  Thérèse Barbier; Roberto Piumatti; Bertrand Hecker; Freddy Odille; Jacques Felblinger; Cédric Pasquier
Journal:  MAGMA       Date:  2014-03-15       Impact factor: 2.310

6.  An optically coupled sensor for the measurement of currents induced by MRI gradient fields into endocardial leads.

Authors:  Eugenio Mattei; Federica Censi; Michele Triventi; Antonio Napolitano; Elisabetta Genovese; Vittorio Cannatà; Giovanni Calcagnini
Journal:  MAGMA       Date:  2014-10-11       Impact factor: 2.310

7.  RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: The role of surgical lead management.

Authors:  Laleh Golestanirad; John Kirsch; Giorgio Bonmassar; Sean Downs; Behzad Elahi; Alastair Martin; Maria-Ida Iacono; Leonardo M Angelone; Boris Keil; Lawrence L Wald; Julie Pilitsis
Journal:  Neuroimage       Date:  2018-09-19       Impact factor: 6.556

8.  MRI-based transfer function determination for the assessment of implant safety.

Authors:  J P Tokaya; A J E Raaijmakers; P R Luijten; J F Bakker; C A T van den Berg
Journal:  Magn Reson Med       Date:  2017-02-05       Impact factor: 4.668

9.  Programmable infusion pump and catheter: evaluation using 3-tesla magnetic resonance imaging.

Authors:  Frank G Shellock; Rocco Crivelli; Ramakrishna Venugopalan
Journal:  Neuromodulation       Date:  2008-07

10.  A novel brain stimulation technology provides compatibility with MRI.

Authors:  Peter Serano; Leonardo M Angelone; Husam Katnani; Emad Eskandar; Giorgio Bonmassar
Journal:  Sci Rep       Date:  2015-04-29       Impact factor: 4.379

View more
  1 in total

Review 1.  New Insights into MR Safety for Implantable Medical Devices.

Authors:  Kagayaki Kuroda; Satoshi Yatsushiro
Journal:  Magn Reson Med Sci       Date:  2022-02-25       Impact factor: 2.760

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.