Literature DB >> 31297671

Aortic roots assessment by an automated three-dimensional transesophageal echocardiography: an intra-individual comparison.

Minghui Zhang1, Linyuan Wan1, Kun Liu2, Weichun Wu1, Hui Li1, Yuan Wang3, Bin Lu2, Hao Wang4.   

Abstract

To evaluate the accuracy, reproducibility, and transcatheter heart valve (THV) sizing efficiency of an automated 3-dimensional transesophageal echocardiographic (3D-TEE) post-processing software in the assessments of aortic roots, intra-individually compared with multidetector computed tomography (MDCT). We prospectively studied 67 patients with normal aortic roots. We measured diameters of aortic annulus (AA), sinus of Valsalva (SOV), and sino-tubular junction (STJ) by full-automated and semi-automated methods using 3D-TEE datasets, then compared them to corresponding transthoracic echocardiography and MDCT values. THV sizes were chosen based on echocardiography and MDCT measurements according to recommended criterion. Taking MDCT planimetered diameters as reference, the full-automated (r: 0.4745-0.8792) and semi-automated (r: 0.6647-0.8805) 3D-TEE measurements were linearly correlated (p < 0.0001). The average differences between semi-automated or full-automated measurements and reference were 0.3 mm or 1.3 mm for AA, - 1.9 mm or - 0.5 mm for SOV, and - 0.1 mm or 1.9 mm for STJ, respectively. The intra-class correlation coefficients of semi-automated method were 0.79-0.96 (intra-observer) and 0.75-0.92 (inter-observer). THV sizing by semi-automated measurements using echocardiographic criteria was larger than that by MDCT measurements using MDCT criteria (p < 0.0001) but equivalent (p > 0.05) if both using MDCT standards. The new automated 3D-TEE software allows modeling and quantifying aortic roots with high reproducibility. Measurements by the semi-automated method closely approximate and well correlate with the corresponding MDCT, thus THV sizing by this modeled 3D-TEE measurements should adopt recommended MDCT criteria but not echocardiographic criteria. The full-automated 3D-TEE segmentations are yet immature. (Semi-automated assessMent of Aortic Roots by Three-dimensional transEsophageal echocaRdiography [SMARTER], NCT02724709).

Entities:  

Keywords:  Automated measurement; Multidetector computed tomography; Three-dimensional transesophageal echocardiography; Transcatheter aortic valve replacement

Year:  2019        PMID: 31297671     DOI: 10.1007/s10554-019-01664-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  30 in total

1.  EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography.

Authors:  Roberto M Lang; Luigi P Badano; Wendy Tsang; David H Adams; Eustachio Agricola; Thomas Buck; Francesco F Faletra; Andreas Franke; Judy Hung; Leopoldo Pérez de Isla; Otto Kamp; Jaroslaw D Kasprzak; Patrizio Lancellotti; Thomas H Marwick; Marti L McCulloch; Mark J Monaghan; Petros Nihoyannopoulos; Natesa G Pandian; Patricia A Pellikka; Mauro Pepi; David A Roberson; Stanton K Shernan; Girish S Shirali; Lissa Sugeng; Folkert J Ten Cate; Mani A Vannan; Jose Luis Zamorano; William A Zoghbi
Journal:  J Am Soc Echocardiogr       Date:  2012-01       Impact factor: 5.251

2.  Accuracy and reproducibility of novel echocardiographic three-dimensional automated software for the assessment of the aortic root in candidates for thanscatheter aortic valve replacement.

Authors:  Ana García-Martín; Carla Lázaro-Rivera; Covadonga Fernández-Golfín; Luisa Salido-Tahoces; Jose-Luis Moya-Mur; Jose-Julio Jiménez-Nacher; Eduardo Casas-Rojo; Iolanda Aquila; Ariana González-Gómez; Rosana Hernández-Antolín; José Luis Zamorano
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-08-27       Impact factor: 6.875

3.  Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.

Authors:  Omar K Khalique; Susheel K Kodali; Jean-Michel Paradis; Tamim M Nazif; Mathew R Williams; Andrew J Einstein; Gregory D Pearson; Kishore Harjai; Kendra Grubb; Isaac George; Martin B Leon; Rebecca T Hahn
Journal:  Circ Cardiovasc Imaging       Date:  2013-11-12       Impact factor: 7.792

Review 4.  Transcatheter Valve Replacement in Asia Pacific: Current Practice and Perspectives.

Authors:  Francesco Giannini; Luca Baldetti; Guglielmo Gallone; Georgios Tzanis; Azeem Latib; Antonio Colombo
Journal:  J Am Coll Cardiol       Date:  2018-12-18       Impact factor: 24.094

5.  Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing.

Authors:  Yuan Wang; Moyang Wang; Guanyuan Song; Wei Wang; Bin Lv; Hao Wang; Yongjian Wu
Journal:  Eur Radiol       Date:  2018-06-20       Impact factor: 5.315

Review 6.  Multimodality Imaging for Planning and Follow-up of Transcatheter Aortic Valve Replacement.

Authors:  Jeanette Soon; Philippe Pibarot; Philipp Blanke; Mickael Ohana; Jonathon Leipsic
Journal:  Can J Cardiol       Date:  2017-04-04       Impact factor: 5.223

7.  Feasibility, Accuracy, and Reproducibility of Aortic Annular and Root Sizing for Transcatheter Aortic Valve Replacement Using Novel Automated Three-Dimensional Echocardiographic Software: Comparison with Multi-Detector Row Computed Tomography.

Authors:  Edgard A Prihadi; Philippe J van Rosendael; E Mara Vollema; Jeroen J Bax; Victoria Delgado; Nina Ajmone Marsan
Journal:  J Am Soc Echocardiogr       Date:  2017-11-23       Impact factor: 5.251

8.  ACR Appropriateness Criteria® Imaging for Transcatheter Aortic Valve Replacement.

Authors:  Jonathon A Leipsic; Philipp Blanke; Michael Hanley; Juan C Batlle; Michael A Bolen; Richard K J Brown; Benoit Desjardins; Robert T Eberhardt; Heather L Gornik; Lynne M Hurwitz; Hersh Maniar; Himanshu J Patel; Elizabeth F Sheybani; Michael L Steigner; Nupur Verma; Suhny Abbara; Frank J Rybicki; Jacobo Kirsch; Karin E Dill
Journal:  J Am Coll Radiol       Date:  2017-11       Impact factor: 5.532

9.  Is MRI equivalent to CT in the guidance of TAVR? A pilot study.

Authors:  Agnes Mayr; Gert Klug; Sebastian J Reinstadler; Hans-Josef Feistritzer; Martin Reindl; Christian Kremser; Christof Kranewitter; Nikolaos Bonaros; Guy Friedrich; Gudrun Feuchtner; Bernhard Metzler
Journal:  Eur Radiol       Date:  2018-05-07       Impact factor: 5.315

10.  Will Artificial Intelligence Replace the Human Echocardiographer?

Authors:  Partho P Sengupta; Donald A Adjeroh
Journal:  Circulation       Date:  2018-10-16       Impact factor: 29.690

View more
  2 in total

Review 1.  Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Chanrith Mork; Minjie Wei; Weixi Jiang; Jianli Ren; Haitao Ran
Journal:  Diagnostics (Basel)       Date:  2021-04-22

2.  Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation.

Authors:  Xin Meng; Yandan Sun; Wei Bai; Yuxi Li; Shengjun Tuo; Liang Cao; Mengmeng Du; Yang Liu; Ping Jin; Jian Yang; Liwen Liu
Journal:  Ann Transl Med       Date:  2022-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.