Literature DB >> 26320167

Accuracy and reproducibility of novel echocardiographic three-dimensional automated software for the assessment of the aortic root in candidates for thanscatheter aortic valve replacement.

Ana García-Martín1, Carla Lázaro-Rivera2, Covadonga Fernández-Golfín2, Luisa Salido-Tahoces2, Jose-Luis Moya-Mur2, Jose-Julio Jiménez-Nacher2, Eduardo Casas-Rojo2, Iolanda Aquila2, Ariana González-Gómez2, Rosana Hernández-Antolín2, José Luis Zamorano2.   

Abstract

AIMS: A specialized three-dimensional transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced; the system automatically configures a geometric model of the aortic root from the images obtained by 3D-TOE and performs quantitative analysis of these structures. The aim of this study was to compare the measurements of the aortic annulus (AA) obtained by the new model to that obtained by 3D-TOE and multidetector computed tomography (MDCT) in candidates to transcatheter aortic valve implantation (TAVI) and to assess the reproducibility of this new method. METHODS AND
RESULTS: We included 31 patients who underwent TAVI. The AA diameters and area were evaluated by the manual 3D-TOE method and by the automatic software. We showed an excellent correlation between the measurements obtained by both methods: intra-class correlation coefficient (ICC): 0.731 (0.508-0.862), r: 0.742 for AA diameter and ICC: 0.723 (0.662-0.923), r: 0.723 for the AA area, with no significant differences regardless of the method used. The interobserver variability was superior for the automatic measurements than for the manual ones. In a subgroup of 10 patients, we also found an excellent correlation between the automatic measurements and those obtained by MDCT, ICC: 0.941 (0.761-0.985), r: 0.901 for AA diameter and ICC: 0.853 (0.409-0.964), r: 0.744 for the AA area.
CONCLUSION: The new automatic 3D-TOE software allows modelling and quantifying the aortic root from 3D-TOE data with high reproducibility. There is good correlation between the automated measurements and other 3D validated techniques. Our results support its use in clinical practice as an alternative to MDCT previous to TAVI. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  3D echocardiography; aortic valve; transcatheter aortic valve implantation

Mesh:

Year:  2015        PMID: 26320167     DOI: 10.1093/ehjci/jev204

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  6 in total

1.  Aortic roots assessment by an automated three-dimensional transesophageal echocardiography: an intra-individual comparison.

Authors:  Minghui Zhang; Linyuan Wan; Kun Liu; Weichun Wu; Hui Li; Yuan Wang; Bin Lu; Hao Wang
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-11       Impact factor: 2.357

Review 2.  3D transoesophageal echocardiography in the TAVI sizing arena: should we do it and how do we do it?

Authors:  Caroline Bleakley; Mehdi Eskandari; Mark Monaghan
Journal:  Echo Res Pract       Date:  2017-03

3.  Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols.

Authors:  Nina P Hofmann; Moritz Schuetz; Raffi Bekeredjian; Sven Pleger; Emanuel Chorianopoulos; Sorin Giusca; Florian André; Gitsios Gitsioudis; Christopher Schlett; Hans-Ulrich Kauczor; Hugo A Katus; Grigorios Korosoglou
Journal:  Eur J Radiol Open       Date:  2017-06-26

Review 4.  Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Chanrith Mork; Minjie Wei; Weixi Jiang; Jianli Ren; Haitao Ran
Journal:  Diagnostics (Basel)       Date:  2021-04-22

5.  Three-Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta-Analysis.

Authors:  Lisa Q Rong; Irbaz Hameed; Arash Salemi; Mohamed Rahouma; Faiza M Khan; Harindra C Wijeysundera; Dominick J Angiolillo; Linda Shore-Lesserson; Giuseppe Biondi-Zoccai; Leonard N Girardi; Stephen E Fremes; Mario Gaudino
Journal:  J Am Heart Assoc       Date:  2019-09-24       Impact factor: 5.501

6.  Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography.

Authors:  Iolanda Aquila; Covadonga Fernández-Golfín; Luis Miguel Rincon; Ariana González; Ana García Martín; Rocio Hinojar; Jose Julio Jimenez Nacher; Ciro Indolfi; Jose Luis Zamorano
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.