Yuanqiang Hao1, Shu Chen2, Yanli Zhou3, Yintang Zhang1, Maotian Xu4,5. 1. Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China. 2. Key Laboratory of Theoretical Organic Chemistry and Function Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China. 3. Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China. zhouyanli@mails.ucas.ac.cn. 4. Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China. xumaotian@sqnu.edu.cn. 5. College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, China. xumaotian@sqnu.edu.cn.
Abstract
Metal-organic frameworks (MOFs), as a class of crystalline hybrid architectures, consist of metal ions and organic ligands and have displayed great potential in luminescent sensing applications due to their tunable structures and unique photophysical properties. Until now, many studies have been reported on the development of MOF-based luminescent sensors, which can be classified into two major categories: MOF chemosensors based on reversible host-guest interactions and MOF chemodosimeters based on the irreversible reactions between targets with a probe. In this review, we summarize the recently developed luminescent MOF-based chemodosimeters for various analytes, including H2S, HClO, biothiols, fluoride ions, redox-active biomolecules, Hg2+, and CN-. In addition, some remaining challenges and future perspectives in this area are also discussed.
Metal-organic n class="Chemical">frameworks (MOFs), as a class of crystalline hybrid architectures, consist ofmetal ions and organic ligands and have displayed great potential in luminescent sensing applications due to their tunable structures and unique photophysical properties. Until now, many studies have been reported on the development ofMOF-based luminescent sensors, which can be classified into two major categories: MOF chemosensors based on reversible host-guest interactions andMOF chemodosimeters based on the irreversible reactions between targets with a probe. In this review, we summarize the recently developed luminescent MOF-based chemodosimeters for various analytes, including H2S, HClO, biothiols, fluoride ions, redox-active biomolecules, Hg2+, and CN-. In addition, some remaining challenges andfuture perspectives in this area are also discussed.
Metal–organic n class="Chemical">frameworks (MOFs), constructed by metal ions (or clusters) with organic ligands, are a subclass of coordination polymers with highly crystalline structures [1,2]. In the past two decades, enormous progress has been made in the synthesis and application ofMOFs [3,4,5]. Because of their remarkable structuralfeatures, such as high porosity and large surface area, as well as their exceptional physicochemical properties, MOFs possess versatile applications in gas storage and separation [6,7,8,9,10,11], heterogeneous catalysis [12,13,14,15], drug delivery and chemotherapy [16,17], and sensing [18,19]. As new types of promising functional materials, luminescent MOFs especially have great potential as alternative phosphors in lighting devices and luminescent sensors [20,21,22,23].
Due to the versatile builn class="Chemical">ding blocks ofMOFs (inorganic ions and organic ligand molecules), as well as their structuraldiversity, the photoluminescence ofMOFs can arise from a variety of possibilities [20]: (i) luminescence from organic linkers, which are normally extended π-conjugation systems with rigid structures, such as pyrene, anthracene, and their derivatives; (ii) metal-based emissions, e.g., MOFs with metal centers of lanthanoid; (iii) a metal–to–ligand charge transfer (MLCT), e.g., d10 Cu(I)- and Ag(I)-basedMOFs; (iv) a ligand–to–metal charge transfer (LMCT), e.g., Zn(II)/Cd(II) and carboxylate ligand basedMOFs; (v) antennae effects; and (vi) sensitization, e.g., MOFs with absorbing ligands and emitting lanthanoid ions (Figure 1). In the past, the competent luminescence features ofMOFs have been extensively studied and exploited in fluorescence imaging and sensing applications [24]. These developedMOF-based luminescent probes can be classified into two types according to the recognition mechanism between the probe with the target analyte: (1) an MOF-based chemosensor, in which the analyte coordinates or interacts with the probe in a reversible manner, such as via physical/electrostatic interaction; (2) an MOF-based chemodosimeter, in which the target analyte can irreversibly react with a probe to yield a product that is chemically different from the starting probe via target-induced oxidation, hydrolysis, and nucleophilic processes.
Figure 1
(a) Partial energy-level diagram for photoluminescent processes; (b) various possibilities for the emission of metal–organic frameworks (MOFs). Reproduced with permission from [24]. Copyright the Royal Society of Chemistry, 2017.
MOF-basen class="Chemical">d luminescent chemosensors have shown great potential in the detection of various analytes, including volatile organic compounds [25,26,27], ions (especially for metal cations) [28,29,30,31], gases [32,33,34,35], as well as for monitoring pH [36,37,38,39,40,41,42], humidity [43,44,45], and temperature [46,47,48]. Compared to the relatively well-developedfluorescent MOFs chemosensors, MOF-based chemodosimeters are expected to be more efficient in terms of selectivity, as they exploit the specific reactivities of certain target analytes [24]. Moreover, numerous MOF-based luminescent chemodosimeters can be afforded by introducing various recognition moieties for different analytes into building blocks. In the past several years, considerable effort has been expended in this field, and research interest is still growing. In spite of this interest, to date, the studies concerning MOF-based chemodosimeters have not yet been comprehensively addressed. To fill this gap, in the present review, we will make an effort to summarize recent progress in the development ofMOF-based chemodosimeters. Moreover, the promising prospects and remaining challenges for future research in the field will also be discussed.
2. MOF-Based Luminescent Chemodosimeters for Sulfur Compounds
2.1. MOF-Based Chemodosimeters for H2S
Hydrogen sulfide (n class="Gene">H2S), the smallest sulfhydryl compound, exists as a typical rotten egg smelling gas in the air or as a hydrosulfide ion while being dissolved in an aqueous solution under neutral pH conditions. Traditionally, H2S was simply considered to be an environmentally toxic species. In recent years, H2S has been discovered to be an essential biological molecule that can function as a cytoprotectant and gasotransmitter in organisms [49,50]. Moreover, the metabolism ofH2S is closely related to various physiological and pathological events in the human body [51,52]. In this context, the development of new methods for sensing H2S and studying its biological roles has attracted tremendous attention [53,54,55]. Fluorescence technology is particularly promising for such purposes, as it enables monitoring of the target with superior temporal and spatial resolution [56,57,58,59], especially for in vivo applications. By exploiting its unique characteristics, such as strong nucleophilicity and ability to reduce potency, various small-molecule fluorescent probes have been developedfor detecting and imaging H2S. These probes can be mainly categorized into three types according to their sensing strategy: (i) sensors based on the H2S-mediated reduction of an azide/nitro group to the amine [60,61,62,63]; (ii) sensors based on the H2S-participated nucleophilic reaction [64,65,66,67]; and (iii) sensors based on the binding reaction between sulfide andCu2+ [68,69]. By exploiting the similar sensing strategies and carefully employing post-synthetic modification approaches, a number ofMOF-basedfluorescent H2S probes (Table 1) were successfully constructed in the last few years [70].
Table 1
List of MOF-based luminescent chemodosimeters for H2S.
MOF Formula
λex/λem (nm)
Dynamic Range
LOD 1
RT 2
Media
Real Sampe
Ref.
Zr6O4(OH)4(BDC-N3)6
334/436
0–4 mM
117 μM
180 s
HEPES buffer (10 mM, pH 7.4)
Live cells
[71]
Zr6O4(OH)4(BDC-NO2)6
334/436
0–4 mM
188 μM
460 s
HEPES buffer (10 mM, pH 7.4)
--
[72]
Zn4O(OH)4(BDC-N3)3
395/455
0–0.5 mM
28.3 μM
90 s
HEPES ethanol buffer (10 mM, pH 7.4)
--
[73]
Ce6O4(OH)4(BDC-N3)6
334/429
0–3.5 mM
12.2 μM
760 s
HEPES buffer (10 mM, pH 7.4)
--
[74]
Ce6O4(OH)4(BDC-NO2)6
334/429
0–3.5 mM
34.8 μM
480 s
HEPES buffer (10 mM, pH 7.4)
--
[74]
Al(OH)(IPA-N3)
330/405
0–0.06 mM
2.65 μM
420 s
HEPES buffer (10 mM, pH 7.4)
Live cells
[75]
Zr6O4(OH)4((NDC-(NO2)2)6
390/474
0.1–0.7 mM
20 μM
50 min
HEPES buffer (10 mM, pH 7.4)
Live cells
[76]
Al(OH)(BDC-N3)
315/425
0.2–1.6 μM
90.47 nM
60 s
HEPES buffer (10 mM, pH 7.4)
Live cells
[77]
Al3O4(OH)4(BDC-(NO2)2)6
345/527
0.1–0.6 mM
14.14 μM
40 min
HEPES buffer (10 mM, pH 7.4)
Live cells
[78]
Al3(O)(OH)(BDC-N3)3
343/460, 565
0.1–120 μM
100 nM
--
Hank’s balanced salt solution
Cell sample
[79]
Al(OH)(BDC-NO2)/poly(vinylidene fluoride)
396/466
0–0.1 mM
92.31 nM
--
PVDF membrane
Lake water
[80]
Cu(TCPP)[AlOH]2
419/602, 650
0–10 μM
16 nM
instant
BBS buffer (20 mM, pH 7.4)
Live cells
[81]
CuO@TO@UiO-66
510/~560
0–100 μM
0.51 μM
instant
Tris-HCl butter (20 mM, pH 7.4)
Live cells
[82]
Eu3+/Cu2+@UiO-66-(COOH)2
305/393, 615
0–625 μM
5.45 μM
30 s
HEPES buffer (10 mM, pH 7.4)
--
[83]
Eu3+/Ag+@UiO-66-(COOH)2
305/615
0–2.5 mM
23.53 μM
30 s
HEPES buffer (10 mM, pH 7.4)
Serum
[84]
Tb3+@[Cu(CPOC)2]
280/390, 544
0–1.6 mM
13.25 μM
2 min
HEPES buffer (10 mM, pH 7.4)
--
[85]
UiO-66-CH = CH2 Zr6O4(OH)4(BDC-CH = CH2)6
328/382
0–0.05 mM
6.46 μM
10 s
HEPES buffer (10 mM, pH 7.4)
Live cells
[86]
FeIII-MIL-88-NH2
333/~440
60–100 μM
10 μM
5 min
Aqueous solution
--
[87]
1 LOD means limit of detection. 2 RT means reaction time.
2.1.1. Based on the H2S-Mediated Reduction of Azide/Nitro Group to Amine
Ghosh et al. n class="Chemical">first reported a Zr-basedMOF, Zr6O4(OH)4(BDC-N3)6 (UiO-66@N3), bearing an azide group for sensing H2S [71]. The MOF-based chemodosimeter UiO-66@N3 was prepared via post modification of the aminefunctionalizedUiO-66@NH2 using an azidation agent. UiO-66@N3 is highly stable in an aqueous solution andfluoresces very weakly due to the presence of an electron-deficient azide group (Figure 2). Treating UiO-66@N3 with Na2S in an HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) aqueous buffer (10 mM, pH 7.4) creates a strong emission (16-fold enhancement), which can be ascribed to the target-mediated reduction ofazide to amine, which produces the luminescent UiO-66@NH2. This conversion process is characterized by FTIR (Fourier Transform infrared spectroscopy) andNMR (Nuclear Magnetic Resonance Spectroscopy) studies. UiO-66@N3 can respond rapidly to H2S (less than 180 s) with high selectivity over other interferences, including most abundant biothiols (Cys andGSH). Moreover, UiO-66@N3 also displays low cell viability and has been applied to live cell imaging studies. The same research group subsequently prepared a nitro-functionalizedZr-MOF (UiO-66@NO2) for the fluorescence turn-on detection ofH2S, in which UiO-66@NO2 can be facilely obtained in a single synthetic step by using 2-nitroterephthalic acid as the ligand [72]. Incorporation of the azide/nitro group onto other MOFs scaffolds has afforded a variety of luminescent H2S chemodosimeters. Qian et al. reported an azide-appendedZn-MOFfor the fluorescent turn-on detection ofH2S [73]. In a HEPESethanol buffer, the probe displayed excellent selectivity and a rapid response time for H2S. By directly reacting the cerium(IV) nitrate with an azide/nitro-substituted 1,4-benzenedicarboxylate (BDC), Biswas et al. synthesized two Ce-MOFs (Ce-UiO-66@N3, Ce-UiO-66@NO2) for sensing H2S [74]. Since then, the Biswas group has developed a number of reaction-based luminescent H2S sensors, including Al(OH)(IPA-N3) [75], Zr6O4(OH)4((NDC-(NO2)2)6 [76], Al(OH)(BDC-N3) [77], andZr6O4(OH)4(BDC-(NO2)2)6 [78]. Further, Al(OH)(BDC-N3) was also employed as a turn-offfluorimetric sensor for detecting Fe(III) in an aqueous solution [77].
Figure 2
The synthetic route and sensing mechanism of UiO-66@N3 for H2S. Reproduced with permission from [71]. Copyright Nature Publishing Group, 2014.
Canivet et al. reporten class="Chemical">d an Al-MOF, Al3(O)(OH)(BDC-N3)3 (Al-MIL-101-N3, Figure 3a) based sensing system for H2S [79]. It is worth noting that the use of a femtosecond (fs)-pulse laser excitation can significantly improve the emissionfeatures as well as the analytical performances of this MOF-based luminescent assay. All these investigatedBDC-basedMOFs (Al-MIL-101-NH2, In-MIL-68-NH2, andZr-UiO-66-NH2) displayed characteristic emissions at about 460 nm (Figure 3b) under UV-lamp excitation at 343 nm. While under fs-pulse laser excitation, Al-MIL-101-NH2 revealed another predominent emission band centered at 565 nm, which may have resultedfrom an increase of the luminescence center in the electronic excited state and the redistribution of the photoexcited charge carriers (Figure 3c,d). The spectral behaviors ofAl-MIL-101-N3for H2S were studied in DMSO (dimethyl sulfoxide) as well as in HBSS (Hank’s balanced salt solution). In the biological media of HBSS, Al-MIL-101-N3displayed a wide dynamic range of 0.1–120 μM and a low LOD of 100 nM for H2S (Figure 3e,f). Moreover, Al-MIL-101-N3 was applied to detect sulfidefrom an exogenous small molecule releaser (GYY4137) and endogenous H2S produced by 3T3L1 cells (Figure 3g,h).
Figure 3
(a) Azido-MOFs for H2S sensing. (b,c) Emission spectra of dry MOF samples, Al-MIL-101-NH2 (blue), In-MIL-68-NH2 (red), Zr-UiO-66-NH2 (black), Al-MIL-101-N3 (green) under UV-lamp excitation (b) or fs-pulse laser excitation (c) at 343 nm. (d) Proposed schematic mechanisms of charges recombination underpinning the observed switch in emission channels. (e) Emission spectra of Al-MIL-101-N3 in the presence of different concentrations of sodium sulfide (excited at 343 nm with a fs-pulse laser). (f) Reversed cubic fit of sodium sulfide concentration vs. measured intensity of the 565 nm band in emission spectra. (g) Detection of H2S released from GYY4137. (h) Exposure of Al-MIL-101-N3 to a sample of culture medium for cells with endogenously produced H2S. Reproduced with permission from [79]. Copyright Wiley-VCH, 2016.
By integrating n class="Chemical">Al-MOF (Al(OH)(BDC-NO2), Al-MIL-53-NO2), andpoly(vinylidene fluoride) (PVDF), Qian et al. developed a novel MMM (MOF-polymer mixed-matrix membrane) for the fluorescence turn-on detection ofH2S [80]. The Al-MIL-53-NO2@PVDF MMM can be readily prepared with a high loading of the MOF probes (70 wt%), following the procedures as depicted in Figure 4a. The obtainedAl-MIL-53-NO2 MMM is mechanically robust andflexible and can be easily handled. The Al-MIL-53-NO2 MMM can be effectively applied to the flow-through detection ofH2S, which exhibited remarkably high sensitivity with an LOD of 92.31 nM (Figure 4b,c).
Figure 4
(a) Fabrication process for Al-MIL-53-NO2@PVDF MOF-polymer mixed-matrix membranes (MMMs). (b) Fluorescence spectra of Al-MIL-53-NO2@PVDF MMMs (70 wt%) with different concentrations of H2S (excited at 396 nm). (c) Fluorescence response of Al-MIL-53-NO2 MMMs at 466 nm toward various analytes. Reproduced with permission from [80]. Copyright Wiley-VCH, 2016.
Furthermore, the constructen class="Chemical">d Al-MIL-53-NO2 MMM was also used to detect H2S in realwater samples.
2.1.2. Based on the Binding Reaction between S2− and Cu2+
Tang et al. firstly reported a Cu(II)-metalatedMOF, Cu(TCPP)[AlOH]2 (TCPP: meso-tetrakis(4-carboxylphenyl)porphyrin), for luminescent sensing ofH2S [81]. Cu(TCPP)[AlOH]2 was obtained via Cu(II)metalation of the porphyrin ring-contained parent MOFTCPP[AlOH]2(DMF)3(H2O)2. The paramagnetic Cu(II) ions can quench the ligand-based (porphyrin) fluorescence ofCu(TCPP)[AlOH]2. Upon the addition ofH2S, the Cu(II) ion can be taken from the porphyrin center via the formation of a CuS precipitate, thereby leading to the recovery ofporphyrin-based emissions in the MOF system (Figure 5a). The fluorescence response ofCu(TCPP)[AlOH]2 to H2S can occur instantaneously with high sensitivity (LOD: 16 nM) and excellent selectivity as other analytes did not generate any fluorescence enhancement. Luminescence imaging studies also demonstrated that Cu(TCPP)[AlOH]2 can be employedfor monitoring both exogenous and endogenic H2S in liver hepatocellular (HepG2) cells (Figure 5b). The Tang group recently developed a CuONPs functionalizedNMOF (Nanoscale metal–organic frameworks) hybrid nanoprobe, CuO@TO@UiO-66, for the sensing and imaging ofH2S [82]. Due to the energy transfer process from TO@UiO-66 to CuONPs, the nanoprobe is weakly emissive. Sulfide can react with CuO to release the luminescent TO@UiO-66, thereby achieving a sensitive turn-on fluorescence response to H2S.
Figure 5
(a) The proposed strategy for the fluorescent variation of Cu(TCPP)[AlOH]2 for H2S. (b) Confocal fluorescence images in living cells: (1) image of HepG2 cells incubated with 10 μM Cu(TCPP)[AlOH]2; (2) bright-field image of (1); (3) image of HepG2 cells incubated with 10 μM Cu(TCPP)[AlOH]2 and 50 μM NaHS; (4) bright-field image of (3); (5) image of A549 cells incubated with 500 μM SNP and 10 μM Cu(TCPP)[AlOH]2; (6) bright-field image of (5); (7) image of A549 cells incubated with 250 mg·L−1
dl-propargylglycine (PPG) and 10 μM Cu(TCPP)[AlOH]2; (8) bright-field image of (7). Reproduced with permission from [81]. Copyright American Chemical Society, 2014.
Qian et al. preparen class="Chemical">d a nano MOFEu3+/Cu2+@UiO-66-(COOH)2 system for the ratiometric luminescent sensing ofH2S by the post-modification ofUiO-66-(COOH)2 with Eu3+ andCu2+ ions [83]. This MOF system displayed two distinct emissions, a sharp Eu3+ emission at 615 nm and a broad ligand-based emission at 393 nm. Due to the decreased antenna efficiency of the H4btec ligands to Eu3+ in the presence ofCu2+, Eu3+/Cu2+@UiO-66-(COOH)2 exhibited a weak Eu3+ emission and a relatively enhanced ligand-based emission. While the target sulfide can effectively snatch the copper ion from the MOF probe and result in a significant enhancement in the fluorescence intensity ratio (I615/I393), thus achieving a ratiometric fluorescence response for H2S (Figure 6). Other advantageous features of this MOF sensor include excellent compatibility with aqueous media and instant response. However, it should be noted that other sulfhydryl compounds (i.e., GSH, Hcy, andCys) also generated a certain degree offluorescence response, which may be ascribed to the moderate binding affinity of H4btec to Cu2+, and these interferences also competitively bind to Cu2+. The same research group consequently developed a fluorescent MOF-based logic platform Eu3+/Ag+@UiO-66-(COOH)2 for H2Sdetection [84].
Figure 6
The fluorescence detection mechanism of the MOF Eu3+/Cu2+@UiO-66-(COOH)2 system for H2S. Reproduced with permission from [83]. Copyright American Chemical Society, 2016.
Yang et al. reporten class="Chemical">d a luminescent composite Tb3+@Cu-MOFfor the turn-on ratiometric sensing ofH2S [85]. The synthesis process for Tb3+@Cu-MOF and the sensing mechanism for H2S are shown in Figure 7a. The Cu-MOF, [Cu(CPOC)2] was firstly prepared by reacting copper salt with an organic ligand (CPOC: 5-(4′-carboxyphenoxy) nicotinic acid). SC-XRD (single crystal X-ray diffraction) analysis indicated that [Cu(CPOC)2] belongs to the monoclinic system (P21/c), with a half crystallographically independent metal center and one ligand per asymmetric unit (Figure 7b). The probe Tb3+@Cu-MOF can be readily obtained via post-grafting modification with Tb3+. [Cu(CPOC)2] displayed an emission band at about 390 nm. Tb3+@Cu-MOF showed additional emissions of the Tb3+ ion (at 489, 544, 585, and 620 nm) but with relatively weak intensities because the Cu2+ with an unsaturated electronic state (3d9) has a tendency to gain electrons and thus quench the fluorescence. With the addtion ofsulfide, Cu2+ can be bounded and, as a consequence its quenching effect, can be hindered, leading to a significant and selective increase in the characteristic emissions ofTb3+ (Figure 7c). Noticeably, the Tb3+@Cu-MOF well retained its crystalline structure after being incubated with Na2S.
Figure 7
(a) Synthetic route for Tb3+@Cu-MOF and its sensing mechanism for H2S. (b) Crystalline structure of [Cu(CPOC)2], (1) 2D layers of Cu1; (2) 2D layers of Cu1 viewed along the c axis; (3) 1D channel in the 3D framework; (4) 3D supramolecular framework of [Cu(CPOC)2] through O–H···O interactions; (5) topological representation of the 3D structure. (c) Fluorescence response of Tb3+@[Cu(CPOC)2] towards sulfide and other analytes. Reproduced with permission from [85]. Copyright the Royal Society of Chemistry, 2017.
2.1.3. Other MOF-Based Chemodosimeters for H2S
Cui et n class="Chemical">al. designed a vinyl-functionalizedZr-MOF (UiO-66-CH = CH2) for detecting H2S by using 2-vinylterephthalic acid as the linker ligand [86]. UiO-66-CH = CH2 showed a turn-offfluorescence response towardH2S with high sensitivity and selectivity. This probe also featured low toxicity and goodwater stability, but the sensing mechanism is not discussed in this study. Wang et al. reported a novel turn-on fluorescent assay for H2S based on the target-mediated collapse of an MOF structure (Fe3O(OH2)3(BDC-NH2)3, FeIII-MIL-88-NH2) (Figure 8) [87]. Due to the paramagnetic nature ofFe(III), FeIII-MIL-88-NH2 is non-emissive. Mixing the FeIII-MIL-88-NH2 suspension with a NaHS solution can lead to the breakdown of the MOFs and a release of the luminescent ligand of2-aminoterephthalic acid.
Figure 8
The synthesis and the turn-on fluoresence response of FeIII-MIL-88-NH2 for H2S. Reproduced with permission from [87]. Copyright Elsevier B.V., New York, NY, USA, 2017.
2.2. MOF-Based Chemodosimeters for Biothiols
Biothiols such as n class="Chemical">Cys (cysteine), Hcy (homocysteine), andGSH (glutathione) play vital roles in various physiological and pathological processes [88,89,90,91]. During the past decade, a huge number offluorescent probes have been developedfor sensing and imaging biothiols by exploiting the specific reactivities ofsulfhydryl group and/or amino group [92,93,94,95,96,97,98], including nucleophilic addition to electron-deficient unsaturated bonds, conjugate addition−cyclization reaction, cleavage ofsulfonamide andsulfonate ester, cleavage ofdisulfide, anddisplacement of coordination to the metal complex. MOF-based Chemodosimeters for fluorescent sensing biothiols have emerged in the last two years.
Ghosh et al. reporten class="Chemical">d a turn-on fluorescent probe, UiO-66-DNS, for selective sensing ofbiothiols [99]. UiO-66-DNS was prepared by post-grafting 2,4-dinitrosulfonyl moiety (DNS) to the chemically stable UiO-66-NH2MOF. UiO-66-DNS exhibited weak fluorescence due to the PET (photoinduced electron transfer) from the ligand of2-aminoterephthalic acid to the highly electron-withdrawing functional group ofDNP (Figure 9a). After the addition ofCys to a UiO-66-DNSdispersedwater solution (Figure 9b), a significant enhancement (ca. ∼48-fold) in luminescent intensity at 432 nm was obtained, which can be ascribed to the thiol-mediated cleavage of the DNS moiety and the release ofUiO-66-NH2. Compared with Cys, UiO-66-DNSdisplayed slower response towardGSH because of its intrinsic bulkier feature for diffusing and interacting with the probe. Other amino acids did not generate any obvious enhancement in the emission intensity of the probe (Figure 9c), which demonstrated that the UiO-66-DNS is highly specific to biothiol.
Figure 9
(a) The fluorescence detection mechanism of UiO-66-DNS for biothiols. (b) The fluorescence responses of UiO-66-DNS after addition of different amount of Cys. (c) Relative changes in the fluorescence intensity of UiO-66-DNS upon treatment with various amino acids. Reproduced with permission from [99]. Copyright American Chemical Society, 2016.
Wu et al. n class="Chemical">developed a novel aldehyde-functionalizedMOF, Cd–PPCA (Figure 10a), for selective sensing ofHcy [100]. The Cd–PPCA consisted of a Cd(II) metal center and two types of ligands, H3tca (4,4′,4″-tricarboxyltriphenylamine) andppca (1H-pyrrolo-[2,3-b] pyridine-2-carbaldehyde). XRD (X-ray diffraction) results indicated that Cd–PPCA crystallized in the orthorhombic space group Pbnm with a = 25.500(5), b = 20.600(4), c = 13.700(3) Å (Figure 10b). Each unit building of trinuclear [Cd3(COO)8] contained one ppca ligand, with a nitrogen atom to coordinate with Cd and a desiredaldehydefunctional group for the specific recognition of the target Hcy. Suspended in a HEPES (pH = 7.4) buffer solution, Cd–PPCA showed a weakenedfluorescence emission at about 450 nm compared with similar MOFs comprised ofH3tca ligands andCd2+ nods, which can be attributed to the PET from the triphenylamine groups to the electron withdrawing aldehyde moieties of the ppca ligand. With the addition ofHcy, the emission intensity of the assay showed a significant enhancement (Figure 10c), which can be ascribed to the selective reaction of the aldehyde moiety with Hcy and thus the inhibition of the PET process. This fluorescent response was also observed to be very fast (60 s) and sensitive (LOD: 40 nM). Moreover, the probe Cd–PPCA exhibited excellent specificity for Hcy over other species, including Cys (Figure 10d).
Figure 10
(a) The fluorescence detection mechanism of Cd–PPCA for Hcy. (b) the coordinated environment of the Cd2+ in Cd–PPCA (Top); a two-dimensional double-layer structure composed of Cd2+ and ligands of ppca and H3tca (bottom-left); the Connolly surface of the framework of Cd–PPCA (bottom-right). (c) The fluorescence spectra of Cd–PPCA upon addition of different amounts of Hcy. (d) Results for selectivity and competition tests. Reproduced with permission from [100]. Copyright the Royal Society of Chemistry, 2018.
Wang and Zhang et n class="Chemical">al. developed a novel Zr-MOF basedfluorescent PET switch/sensor, UiO-68-An/Ma [101]. The probe contains two kinds of ligands, one embedded with the anthracene unit serving as the luminophore and the other appended with a maleimide moiety as the PET acceptor (Figure 11a). The multivariate UiO-68-An/Ma favors a pseudo-PET process and only shows very weak fluorescence with an absolute PLQY (photoluminescence quantum yield) of 1.1%. Notably, the fluorescence behavior of UiO-68-An/Ma can be tuned by altering the acceptor moiety and thus the PET process. The authors firstly confirmed the tunable fluorescence response of UiO-68-An/Ma via a reversible D–A reaction with 3-furanmethanol. Furthermore, UiO-68-An/Ma was appliedfor sensing biothiols based on the well-establishedmaleimide–thiol addition reaction. As a solid-state fluorescent turn-on sensor, UiO-68-An/Ma can sensitively response to biothiols (Cys, Hcy, andGSH) as low as 50 µM (Figure 11b).
Figure 11
(a) Synthesis of UiO-68-An/Ma and tuning the fluorescent photoinduced electron transfer (PET) in the MOF through a reversible D–A reaction or thiol-ene reaction. (b) Bright-field and photoluminescence single-crystal images of UiO-68-An/Ma treated with different concentrations of Cys, Hcy, and GSH for 5 min. Reproduced with permission from [101]. Copyright Wiley-VCH, 2016.
With the in-situ encapsulation ofn class="Chemical">rhodamine B (RhB) into Cu-BTC, Gao and Huang et al. reported a turn-on fluorescent assay (RhB@Cu-BTCMOFs) for sensing Cys [102]. The fluorescence ofRhB@Cu-BTC was very weak because the embeddedRhB was adjacent to the paramagnetic copper center. In the presence ofCys, the Cu-BTCframework collapsed, which resulted the release ofRhB and thus a turn-on fluorescence response (Figure 12).
Figure 12
The synthesis of RhB@Cu-BTC and its sensing process for Cys. Reproduced with permission from [102]. Copyright 2018 Elsevier B.V., New York, NY, USA.
The MOF basen class="Chemical">d fluorescent probe has also been exploitedfor sensing sulfur dioxide (SO2) or sulfite/bisulfite, another kind of important sulfur-containing specie on both biological andenvironmental aspects. Ghosh et al. constructed a MOF based luminescent probe, NH2-MIL-68(In)@CHO, for the monitoring ofbisulfite [103]. The probe was prepared by the post synthetic approach via condensation ofNH2-MIL-68(In) (In(OH)(bdc-NH2)) with glyoxal (Figure 13). The introducedaldehyde moiety can react with bisulfite to generate an OH group, which is available to form an intramolecular hydrogen bond and thus resulted in the inhibition of the C = N isomerization and the recovery of the fuorescence of the probe. Cui and Qian et al. prepared a Eu-BDC-NH2film on the UiO-66-NH2 modified glass through an in situ secondary growth and successfully applied this functionalfilm for sensing gaseous sulfur dioxide [104].
Figure 13
The synthesis of NH2-MIL-68(In)@CHO and its sensing process for bisulfite. Reproduced with permission from [103]. Copyright Elsevier B.V., New York, NY, USA, 2018.
3. MOF-Based Chemodosimeters for Other Redox-Active Biomolecules
3.1. MOF-Based Chemodosimeters for HClO
Hypochlorous acid (n class="Chemical">HClO) is an important chemical reagent with wide application in various areas of organic synthesis, the cosmetics industry, food service, water treatment, etc. In living organisms, HClO is a kind ofessentialreactive oxygen species (ROS), which is normally produced in phagosomes via the reaction between hydrogen peroxide andchloride ions catalyzed by myeloperoxidase [105]. As a powerful oxidizer, the endogenous HClO can act as effective microbicidal agent when the host is being invaded by microbials [106]. On ther hand, HClO can also react with functioning biomolecules, such as proteins, nucleic acid, andfatty acids, which would produce adverse effects for organisms and correlate to numerous humandiseases, such as kidney disease, cardiovascular diseases, and even cancers [107]. Therefore, the development of reliable analytical methods for monitoring HClO has attracted a great deal of attention [108,109]. Based on the unique characteristics ofHClO, acting as both a potent oxidant and a good chlorination agent, various reaction-based organic fluorescent probes has been reportedfor selective sensing ofHClO [110,111,112,113,114,115,116,117]. Until now, several examples ofMOF-based chemodosimeters for luminescent detection ofHClO have been presented.
Ma and Wang et n class="Chemical">al. developed the first MOF-based chemodosimetric probe for sensing HClO [118]. The designing strategy for the probe, UiO-Eu-L1 (L1: dimethyl 4-(carbaldehyde oxime) pyridine-2,6-dicarboxylate), is depicted in Figure 14. Uio-Eu-L1 was obtained by successively treating the Zr-MOF UiO-67 (Zr6O4(OH)4(BPDC)6) with europium ions and the functional ligand L1. Due to the efficient C = N isomerization-inducedfluorescence quenching, UiO-Eu-L1 displayed very weak red emissions derivedfrom europium ions. In the presence ofHClO, the hydroxylamine moiety can be converted to aldehyde, which, in turn, leads to the inhibition of the C = N isomerization and thus the turn-on fluorescence response of the probe system. Ascribed to the long-lived phosphorescence of the Uio-Eu basedMOF, this luminescent assay can efficiently eliminate the background signals and auto-fluorescence effects by the use of time-gated measurements. Uio-Eu-L1 also exhibited high sensitivity for HClO with a dynamic range of 0.1–5 μM and a detection limit of 16 nM.
Figure 14
The structure and sensing mechanism of Uio-Eu-L1 for ClO−. Reproduced with permission from [118]. Copyright Elsevier B.V., New York, NY, USA, 2018.
Gu et al. presenten class="Chemical">d a novel luminophore integratedMOF system, AF@MOF-801, for specific detection ofHClO [119]. The composite AF@MOF-801 can be readily prepared via a one-step process by using 5-aminofluorescein (AF) as a co-reactant in the synthesis ofMOF-801 (Figure 15a). AF can serve as a sensitive turn-offfluorescent HClO probe, as HClO can react with AF to produce chlorinated products. However, other coexistent biological molecules (such as dopamine, DA) also can lead to the similar fluorescent changes ofAF. In the constructed sensory platform ofAF@MOF-801, AF can be confined in the cages of the framework and the target HClO can diffuse into the framework to react with the probe AF, while the ultra-small aperture can block the entry of large-sized interferents. Due to this size-selective effect, AF@MOF-801displayed excellent specificity for HClO. Only ClO− produced the significant luminescence response ofAF@MOF-801 (Figure 15b), while both ClO− andDA generated strong fluorescence quenching for the free AF probe (Figure 15c). The feasibility ofAF@MOF-801for monitoring intracellular HClO was also demonstrated by MTT assay andflow cytometry analysis (FCA), as well as confocal laser scanning microscopy (CLSM) measurements (Figure 15d).
Figure 15
(a) Schematic illustration of the synthetic procedure for AF@MOF-801 and the size-selective sensing mechanism toward targe analyte of ClO−. (b) The luminescence responses of free AF for various analytes. (c) The luminescence responses of AF@MOF-801 for various analytes. (d) The confocal laser scanning microscopy images of SMMC-7721 cells incubated with AF@MOF-801 and with various concentrations of ClO−. Reproduced with permission from [119]. Copyright the Royal Society of Chemistry, 2019.
Chen et al. constructen class="Chemical">d a fluorophores@MOF (F1-Rubpy@ZnMOF74) nanocomposite-basedratiometric fluorescent probe for HClO by simultaneously encapsulating two fluorophores, fluorescein o-acrylate (F1) and tris(2,2′-bipyridyl)-dichroruthe-nium(II) hexahydrate (Rubpy), into ZnMOF74 [120]. F1-Rubpy@ZnMOF74displayed two distinct emissions at 512 nm and 600 nm, corresponding to F1 andRubpy, respectively. In the presence ofHClO, the fluorescence of the target-responsive fluorophore F1 can be quenched, while the reference signal that originatedfrom Rubpy remained unchanged, thus achieving a ratiometric response for HClO. In an aqueous HEPES buffer (pH = 7.5) solution, the fluorescence intensity ratio (I512/I600) of the F1-Rubpy@ZnMOF74 was found to be linearly correlated with the concentration ofClO− with a dynamic range of 3.6 nM-100 μM.
3.2. MOF-Based Chemodosimeters for Ascorbic Acid
Chen and Qian et. n class="Chemical">al. developed a Ce-MOF sensor ZJU-136-Ce, (Me2NH2)0.6{[CeIV(TPTC)]0.4-[CeIII(TPTC)]0.6}(H2O)2(H4TPTC = 1,1′:4′,1″-terphenyl-2′,4,4″,5′-tetracarboxylic acid) for sensing ascorbic acid (AA) [121]. CeIV in the probe ZJU-136-Ce can react with the AA to generate CeIII and oxidized AA (DHA, dehydroascorbic acid). ZJU-136-Cedisplays a luminescence band at 380 nm with a lifetime of 0.84 ns, which corresponds to the emissions of the Ce ion (Figure 16a). After reacting with AA, the probe system shows an increased emission band at about 400 nm (Figure 16b), which corresponds to the emission of the ligand. This fluorescence spectral response can be ascribed to the enhanced conjugation effect of the oxidized product DHA and thus the inhabited PET process from the TPTC ligand to the Ce ion. Subsequently, by introducing the Eu ions into the MOFs ZJU-136-Ce, the Qian group constructed a dual-emissive MOFs, ZJU-136-Ce1−xEux (x = 0.24, 0.36), which can serve as an efficient ratiometric probe for monitoring AA [122]. The same research group also reported a new Zn-MOF, ZnL(H2O) (ZJU-137, H2L = 4,4′-(1H-pyrazole-1,3-diyl)dibenzoic acid, for the fluorescence “turn-off” detection of AA [123].
Figure 16
(a) Schematic illustration of the sensing mechanism of ZJU-136-Ce for asorbic acid (AA). (b) Luminescence spectra of ZJU-136-Ce in the presence of different concentrations of AA. Reproduced with permission from [121]. Copyright the Royal Society of Chemistry, 2017.
3.3. MOF-Based Chemodosimeter for 5-Hydroxytryptamine
Shi and Cheng et n class="Chemical">al. presented a Ln-MOF, Ln-MOF 1: {[Eu(TDA)(H2BTEC)0.5(H2O)3]·H2O}n (H2TDA = thiazolidine 2,4-dicaboxylic acid, H4btec = 1,2,4,5-benzenetetracarboxylic acid), for sensing 5-hydroxytryptamine (HT) and 5-hydroxyindole-3-acetic acid (HIAA), which was synthesized by reacting Eu3+ with mixed ligands of H2TDA and H4BTEC [124]. Ln-MOF 1 is crystallized in the monoclinic space group P21/c, in which each Eu3+ ion is nine-coordinates in a spherical capped square antiprism coordination geometry (Figure 17a). Due to the conjugated π system and the pronounced antenna effect of the ligand BTEC, Ln-MOF 1 displays intense characteristic emissions of the Eu3+ emitter with a maximum peak located at 616 nm, which is ascribed to the 5D0→7F2 transition ofEu3+ ion. In the presence ofHT or HIAA, the luminescence of the Ln-MOF 1 can be effectively quenched (Figure 17b,c). This process was attributed to the competitive absorption of excitation light by the analyte and the ligand. Ln-MOF 1 displayed severalfavorable features for HT and HIAA sensing, including high stability over a wide pH range and long-term storage, excellent sensitivity, andfast response time.
Figure 17
(a) structure of Ln-MOF 1: (1) Coordination geometry of the Eu3+; (2) The asymmetric unit of Ln-MOF 1; (3) 3D framework composed of Ln-MOF 1. Atom codes: Eu (green), C (gray), N (blue), O (red), and S (yellow). Emission spectra of Ln-MOF 1 upon addition increase amount of (b) HT and (c) HIAA. Reproduced with permission from [124]. Copyright Wiley-VCH, 2018.
3.4. MOF-Based Chemodosimeter for H2O2
The hydrogen peroxide (n class="Chemical">H2O2) mediated conversion ofarylboronates to phenols has been widely exploitedfor the development offluorescent H2O2 probes [125]. On the basis of this unique chemical reaction, Biswas et al. developed a Zr-MOF based probe, Zr-UiO-66-B(OH)2, for sensing H2O2 [126]. Zr-UiO-66-B(OH)2, which can be can be easily prepared by reacting ZrOCl2·8H2O with the linker ofBDC-B(OH)2 (2-boronobenzene-1,4-dicarboxylic acid) (Figure 18). Zr-UiO-66-B(OH)2 can act as a sensitive and selective off−on luminescent chemodosimeter for H2O2 with a 4-fold increment in the fluorescence intensity upon the addition of an excess amount of the target. Moreover, the probe Zr-UiO-66-B(OH)2 was successfully applied to image H2O2 in MDAMB-231 cells.
Figure 18
Schematic illustration of the sysnthesis of Zr-UiO-66-B(OH)2 and the sensing process for H2O2. Reproduced with permission from [126]. Copyright American Chemical Society, 2018.
4. MOF-Based Chemodosimeters for Ions
4.1. MOF-Based Chemodosimeters for Fluoride Ions
The fluoride ion, n class="Chemical">F−, as a typical hard Lewis base with the smallest ionic radius and highest charge density, has attracted much interest due to its association with various biological, medical, and technological processes. Commonly, fluoride is considered to be a critical component for preventing dental caries as fluoride can promote the formation of enamel-strengthening fluorapatite [127,128,129]. However, the over intake offluoride can lead to excess mineralization within oganisms and cause gastric and kidney problems. Various analytical techniques have been developedfor sensing fluoride [130], including the well-established electrochemical method [131,132], chromatography [133,134], and colorimetric andfluorogenic assays [135]. In the past decades, numerous fluorescent probes have been developedfor fluoride based on different fluoride-participated processes, such as fluoride-induced Si−O or Si−C bond cleavage, H−Fhydrogen bonding formation, and Lewis acid−base interactions [136,137,138]. By exploiting these special reactivities offluoride, severalMOF-based luminesscent probes have recently been developedfor its detection [139,140].
Yin et al. reporten class="Chemical">d a reaction-basedMOF probe (Eu-bop, Eu2(isp)3(H2O)2) for fluoride ions [141]. Eu-bop was prepared by using Eu3+ as the metal node and 5-bop (5-boronoisophthalic acid) as the ligand that contains a recognition moiety of a boric acid group for the target F−. The substitutedboric acid group also can tune the electronic structure of the ligand and resulted in an incomplete energy transfer from the ligand to Eu3+ emitter in the probe Eu-bop. Therefore, the Eu-bopdisplayed two emission bands: 366 nm, corresponding to the ligand of 5-bop; and 570–750 nm, corresponding to Eu3+. Upon the addition offluoride ions, the emission intensity at 366 nm was significant increased with a concomitant decrease in emissions at 625 nm (Figure 19a). The fluorescence response can be ascribed to the OH/F exchange reaction on the boron atom, which changed the hybridization state ofboronfrom sp2 (−B(OH)2) to sp3 (−BF3), and thus disrupted the pπ−π conjugation of the 5-bop and the decreased intersystem crossing efficiency (Figure 19b), as well as the antenna effect of the ligand. The fluorescence intensity ratio (I625/I366) of the probe system was found to vary linearly with the concentration offluoride in a range of 4–80 μM. The probe was also applied to detect fluoride in real samples of river and undergroundwater.
Figure 19
(a) The synthesis of Eu-bop and its sensing process for F−. (b) Schematic representation of absorption, migration, and emission of Eu-bop. Reproduced with permission from [141]. Copyright American Chemical Society, 2017.
Recently, Stylianou et al. n class="Chemical">developed a luminescent lanthanideMOF, ([Eu(tctb)(H2O)]·2DMF), referred to as SION-105for the recognition offluoride ion [142]. SION-105 consisted oftris (p-carboxylic acid) tridurylborane ligand (tctb3−) and an EuIII metal center. The ligand tctb3− contains a three-coordinate B acting as the recognition site for F− and the surrounding duryl groups offering size-selective steric protection from other interferences (Figure 20a). SION-105displayed a strong characteristic EuIII luminescent emissiondue to the efficient antenna effect of the ligand tctb3− (Figure 20d). Upon the addition ofF−, the emissions of the probe can be quencheddue to the specific interaction ofF− with the B Lewis acid site. A linear luminescence quenching response ofSION-105 towards the F− ion was observed in a range of 0.5 to 2.0 ppm (Figure 20b). A Stern−Volmer plot of quenching with the F− concentration indicates the occurrence of both static anddynamic quenching (Figure 20c).
Figure 20
(a) The structure of SION-105 and its sensing process for F−. (b) Luminescence spectra of SION-105 upon the addition of F− with different concentrations. (c) Stern−Volmer plot of quenching with increasing F− concentration. (d) Photographs of SION-105 suspension with or without of F−. Reproduced with permission from [142]. Copyright American Chemical Society, 2019.
4.2. MOF-Based Chemodosimeter for Hg2+
Mercury is one on class="Chemical">f the most toxic heavy metals in the environment. In aqueous media, mercury can be transformed into methylmercury, a powerful neurotoxin, which can be accumulated and ingested by humans through the food chain [143,144,145]. In the human body, methylmercury can lead to serious symptoms, such as cognitive and motor disorders, neurological impairments, brain damage, and even death [146,147,148]. These environmental and biological problems have prompted the rapiddevelopment of techniques for sensing mercury [149,150,151,152,153]. Until present, many reaction-basedfluorescent probes for Hg2+ have been developed based on various Hg2+-induced chemical processes [154,155,156], such as desulfation or deselenization processes, desulfation and cyclization processes, thiol elimination process, and the oxymercuration−elimination of vinyl/alkyne ether. Recently, Ghosh reported a MOF probe (UiO-66@Butyne) for the reaction-baseddetection ofHg2+ [157]. UiO-66@Butyne was preparedfrom Zr ion and a ligand of2,5-bis (but-3-yn-1-yloxy) terephthalic acid, which contained a butyne moiety acting as the recognition site for Hg2+ (Figure 21a). The preparedUiO-66@Butyne retained the crystalline structure ofMOFUiO-66 and showed a strong green emission (λem,max = 537 nm). Addition ofHg2+ to the aqueous solution ofUiO-66@Butyne can result in fluorescent quenching of the system (Figure 21b), which can be attributed to the target-induced conversion ofUiO-66@Butyne to the less fluorescent product ofUiO-66@OH through the process of oxymercuration−elimination ofethynyl ether. As this MOF-based chemodosimeter exploited the specific reactivity of the target, UiO-66@OH exhibited excellent selectivity for Hg2+.
Figure 21
(a) Schematic illustration of the sensing mechanism of UiO-66@Butyne for Hg2+. (b) Fluorescence spectra of UiO-66@Butyne upon addition of different amount of Hg2+. Reproduced with permission from [157]. Copyright American Chemical Society, 2018.
4.3. MOF-Based Chemodosimeter for CN−
The cyanide ion is an extremely poisonous chemicn class="Chemical">al with widespread applications in industries such as metal mining, electroplating, and plastic andfertilizer manufacturing [158,159]. Various methods have been developedfor the quantitative analysis of CN−, including the titration method, electrochemical assays [160], chromatography [161], as well as the colorimetric andfluorogenic method [162]. Among these methods, the design and use offluorescent probes for sensing CN− have received considerable attention [163,164,165]. The chemososimeters for CN− monitoring are normally associated, with several typical chemical reactions, including the cyanohydrinforming process, additions to the dicyano-vinyl group, michael addition, andindolium or pyridinium addition reactions. Recently, based on the specific addtion reaction of CN− dicyano-vinyl group, Ghosh developed a Zeolitic imidazolateframework, M-ZIF-90 ([Zn(C8H6N4O2)]n), for fluorescence sensing CN− [166]. M-ZIF-90 was prepared by incorporating the recognition moiety ofdicyano-vinyl onto the aldehyde-appendedZIF-90 via post-synthetic modification (Figure 22). In the H2O/DMSO (1:1) mixture, M-ZIF-90displayed a turn-offfluorescence response towards CN− based on the nucleophilic addition of CN− to the dicyano-vinyl group, which would interrupt the π-conjugation of the probe and thus result in significant fluorescence change.
Figure 22
Schematic illustration of the the sysnthesis of M-ZIF-90 and the sensing process for CN−. Reproduced with permission from [166]. Copyright Wiley-VCH, 2016.
5. Conclusions
In recent years, the design, synthesis, ann class="Chemical">d application ofMOFs have attracted an ever-increasing interest of researchers in the fields of chemistry, physics, materials, and engineering. The porous and crystalline nature, versatile selections for metal nodes and organic linkers, and tunable structures also endow MOFs with unique characteristics for sensing applications. In this review, we summarized recently developedMOF-based luminescent chemodosimeters. These reaction-based luminescent probes inherit the robust structuralfeatures ofMOFs (e.g., large surface area, high porosity, and good thermal and chemical stability) andalso exhibit excellent selectivity as they exploit the specific reactivities of the target analyte. Several strategies have been involved in the development ofMOF-based chemodosimeters: (i) installing the recognition moiety onto the ligand via a post-synthetic modification approach or using a recognition moiety-appended ligandfor preparing MOFs; (ii) construction of small-molecule fluorescent probe@MOF hybrid nanocomposites, in which the MOFs act as a carrier to confine the responsive probe; (iii) based on the target-induced collapse of the MOF structure, etc. Further, the MOF scaffolds exploitedfor constructing luminescent chemodosimeters are normally required to possess severalfeatures, including high stability anddispersibility in aqueous (or aqueous-containing) media, feasibility of installing the recognition moiety for certain analytes, environmentalfriendliness, and/or good biocompatibility for biosensing and bioimaging applications. Until now, although, dozens ofMOF-based chemodosimeters have been reportedfor different analytes with severaldesirable traits, such as high selectivity and sensitivity, good stability, and rapid response, some critical performance limitations for this type of luminescent probe still need to be improved, including short-wavelength light excitation and/or emission, insufficientdesigning strategies for the probe, and limited target analytes. To overcome these shortcomings, severalfuture directions for the design ofMOF-based chemodosimeters are proposed herein.
(i) Employing New n class="Species">Rationally Designed Ligands
Most of the n class="Chemical">developedMOF-based chemodosimeters are ligand-based emission systems. Currently, the used ligand normally belongs to a blue-emissive fluorophore (e.g., BDC) with ultraviolet to blue light excitation, which is unfavorable for applications in complex samples, as well as in bioimaging. Future efforts shouldfocus on the design and utilization of new ligands for constructing luminescent MOFs that have typical spectralfeatures, such as visible/near-infrared emission, two-photon excitation, and large Stokes shifts.
(ii) Developing n class="Chemical">Dual-LigandMofs Systems
Compared with the single-ligann class="Chemical">d system, the dual-ligandMOFs have greater structural andfunctionaldiversity. For example, a fluorescence resonance energy transfer (FRET) sensing system could be achieved by carefully designing the electronic structure of two different ligands. Ratiometric fluorescent probes could be obtained by using one ligand as the target-responsive unit and the other ligand as the internal signal reference.
(iii) Expanding the Application Scope n class="Chemical">for Mof-Based Chemodosimeters
To date, n class="Chemical">MOF-based chemodosimeters have only been employedfor sensing some ions and small molecules, such as F−, Hg2+, CN−, H2S, HClO, Cys, H2O2, AA, andHT. It is anticipated that future efforts will focus on developing MOF-based chemodosimeters for monitoring other important biomolecules, such as bioenzymes, as well as for bioimaging applications.
In summary, MOF-basen class="Chemical">d luminescent chemodosimeters have increasingly attracted research interest. It can be expected that ongoing studies in this area will lead to the rapiddevelopment of more effective luminescent nanomaterials for sensing and imaging applications.