Literature DB >> 30740969

Selective, Fast-Response, and Regenerable Metal-Organic Framework for Sampling Excess Fluoride Levels in Drinking Water.

Fatmah Mish Ebrahim1, Tu N Nguyen1, Serhii Shyshkanov1,2, Andrzej Gładysiak1, Patrick Favre, Anna Zacharia3, Grigorios Itskos3, Paul J Dyson2, Kyriakos C Stylianou1.   

Abstract

Prolonged consumption of water contaminated with fluoride ions (F-) at concentrations exceeding 1.5 ppm can lead to considerable health implications, particularly in children and developing embryos. With irreversible and potentially severe forms of fluoride (F-) toxicity such as skeletal fluorosis being endemic in at least 25 countries, constructing affordable, remote-access, reliable water-sampling methods for F- contamination is an important goal. In this work, we present a novel lanthanide-based luminescent metal-organic framework, named SION-105, with a boron (B) receptor site whose interactions with F- in aqueous solutions are simultaneously electrostatic and specific in nature because of its carefully designed structural environment. This allows the material to be easily regenerated and used over 10 cycles, setting it apart from most existing molecular and polymeric F- sensors. SION-105 has been combined with a portable prototype sampling device that was designed and built in-house to measure F- concentrations in natural groundwater samples taken from three different countries, with the results showing excellent agreement with ion chromatography analysis.

Entities:  

Year:  2019        PMID: 30740969     DOI: 10.1021/jacs.8b11907

Source DB:  PubMed          Journal:  J Am Chem Soc        ISSN: 0002-7863            Impact factor:   15.419


  4 in total

1.  Selective and Fast Detection of Fluoride-Contaminated Water Based on a Novel Salen-Co-MOF Chemosensor.

Authors:  Maha Alhaddad; Said M El-Sheikh
Journal:  ACS Omega       Date:  2021-05-30

2.  A highly sensitive and selective fluoride sensor based on a riboswitch-regulated transcription coupled with CRISPR-Cas13a tandem reaction.

Authors:  Yuan Ma; Quanbing Mou; Peng Yan; Zhenglin Yang; Ying Xiong; Deyue Yan; Chuan Zhang; Xinyuan Zhu; Yi Lu
Journal:  Chem Sci       Date:  2021-08-09       Impact factor: 9.825

3.  Ultrasensitive colorimetric detection of fluoride and arsenate in water and mammalian cells using recyclable metal oxacalixarene probe: a lateral flow assay.

Authors:  Shuvankar Dey; Anshu Kumar; Pradip Kumar Mondal; Deepak Chopra; Rupam Roy; Sana Jindani; Bishwajit Ganguly; Chaithra Mayya; Dhiraj Bhatia; Vinod K Jain
Journal:  Sci Rep       Date:  2022-10-12       Impact factor: 4.996

Review 4.  Improving MOF stability: approaches and applications.

Authors:  Meili Ding; Xuechao Cai; Hai-Long Jiang
Journal:  Chem Sci       Date:  2019-10-02       Impact factor: 9.825

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.