Literature DB >> 31270858

Characterizing a short T2 * signal component in the liver using ultrashort TE chemical shift-encoded MRI at 1.5T and 3.0T.

Ante Zhu1,2, Diego Hernando2,3, Kevin M Johnson2,3, Scott B Reeder1,2,3,4,5.   

Abstract

PURPOSE: Recent studies have suggested the presence of short-T2 * signals in the liver, which may confound chemical shift-encoded (CSE) fat quantification when using short echo times (TEs). The purpose of this study was to characterize the liver signal at short echo times and to determine its impact on liver fat quantification.
METHODS: An ultrashort echo time (UTE) chemical shift-encoded MRI (CSE-MRI) technique and a multicomponent reconstruction were developed to characterize short-T2 * liver signals. Subsequently, liver fat fraction was quantified using a short-TE (first TE = 0.7 ms) and UTE CSE-MRI acquisitions and compared with a standard CSE-MRI (first TE = 1.2 ms).
RESULTS: Short-T2 * signals were consistently observed in the liver of all healthy volunteers imaged at both 1.5T and 3.0T. At 3.0T, short-T2 * signal fractions of 9.6 ± 1.5%, 7.0 ± 1.7%, and 7.4 ± 1.7% with T2 * of 0.23 ± 0.05 ms, 0.20 ± 0.05 ms, and 0.10 ± 0.02 ms were measured in healthy volunteers, patients with liver cirrhotic disease, and patients with hepatic steatosis (but no cirrhosis), respectively. For proton density fat fraction (PDFF) estimation, 1.7% (P < .01) and 3.4% (P < .01) biases were observed in subjects imaged using short-TE CSE-MRI and using UTE CSE-MRI at 1.5T, respectively. The biases were reduced to 0.4% and -0.7%, respectively, by excluding short echoes less than 1 ms. A 3.2% bias (P < .01) was observed in subjects imaged using UTE CSE-MRI at 3.0T, which was reduced to 0.1% by excluding short echoes <1 ms.
CONCLUSIONS: A liver short-T2 * signal component was consistently observed and was shown to confound liver fat quantification when short echo times were used with CSE-MRI.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  chemical shift-encoded; liver MRI; quantitative imaging; short T2*; ultrashort TE

Mesh:

Substances:

Year:  2019        PMID: 31270858      PMCID: PMC6717026          DOI: 10.1002/mrm.27876

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

Review 1.  The global NAFLD epidemic.

Authors:  Rohit Loomba; Arun J Sanyal
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2013-09-17       Impact factor: 46.802

2.  On the confounding effect of temperature on chemical shift-encoded fat quantification.

Authors:  Diego Hernando; Samir D Sharma; Harald Kramer; Scott B Reeder
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

3.  Correction of phase errors in quantitative water-fat imaging using a monopolar time-interleaved multi-echo gradient echo sequence.

Authors:  Stefan Ruschke; Holger Eggers; Hendrik Kooijman; Maximilian N Diefenbach; Thomas Baum; Axel Haase; Ernst J Rummeny; Houchun H Hu; Dimitrios C Karampinos
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

4.  Quantitative ultrashort TE imaging of the short-T2 components in skeletal muscle using an extended echo-subtraction method.

Authors:  Ericky C A Araujo; N Azzabou; A Vignaud; G Guillot; P G Carlier
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

Review 5.  Linearity, Bias, and Precision of Hepatic Proton Density Fat Fraction Measurements by Using MR Imaging: A Meta-Analysis.

Authors:  Takeshi Yokoo; Suraj D Serai; Ali Pirasteh; Mustafa R Bashir; Gavin Hamilton; Diego Hernando; Houchun H Hu; Holger Hetterich; Jens-Peter Kühn; Guido M Kukuk; Rohit Loomba; Michael S Middleton; Nancy A Obuchowski; Ji Soo Song; An Tang; Xinhuai Wu; Scott B Reeder; Claude B Sirlin
Journal:  Radiology       Date:  2017-09-11       Impact factor: 11.105

6.  Collagen types in normal and cirrhotic liver.

Authors:  M Rojkind; M A Giambrone; L Biempica
Journal:  Gastroenterology       Date:  1979-04       Impact factor: 22.682

7.  Free-breathing liver fat quantification using a multiecho 3D stack-of-radial technique.

Authors:  Tess Armstrong; Isabel Dregely; Alto Stemmer; Fei Han; Yutaka Natsuaki; Kyunghyun Sung; Holden H Wu
Journal:  Magn Reson Med       Date:  2017-04-16       Impact factor: 4.668

8.  Multipeak fat-corrected complex R2* relaxometry: theory, optimization, and clinical validation.

Authors:  Diego Hernando; J Harald Kramer; Scott B Reeder
Journal:  Magn Reson Med       Date:  2013-01-28       Impact factor: 4.668

9.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

10.  In vivo characterization of brain ultrashort-T2 components.

Authors:  Tanguy Boucneau; Peng Cao; Shuyu Tang; Misung Han; Duan Xu; Roland G Henry; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2017-12-01       Impact factor: 4.668

View more
  1 in total

1.  Integrated quantitative susceptibility and R2 * mapping for evaluation of liver fibrosis: An ex vivo feasibility study.

Authors:  Ramin Jafari; Stefanie J Hectors; Anne K Koehne de González; Pascal Spincemaille; Martin R Prince; Gary M Brittenham; Yi Wang
Journal:  NMR Biomed       Date:  2020-09-22       Impact factor: 4.044

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.