Literature DB >> 31239430

On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

M Pizzichemi1, A Polesel, G Stringhini, S Gundacker, P Lecoq, S Tavernier, M Paganoni, E Auffray.   

Abstract

The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed and tested. For these purposes, a dedicated 64-channels readout setup has been developed with intrinsic timing resolution of 16 ps FWHM. Several PET modules have been produced, based on LYSO:Ce scintillators and commercial silicon photomultiplier (SiPM) arrays, with [Formula: see text] mm2 individual SiPM size. The results show the possibility to achieve a timing resolution of 157 ps FWHM, combined with the already demonstrated spatial resolution of 1.5 mm FWHM, DOI resolution of 3 mm FWHM, and energy resolution of 9% FWHM at 511 keV, with 15 mm long crystals of section [Formula: see text] mm2 and [Formula: see text] mm2. At the same time, the extraction of the DOI coordinate has been demonstrated not to deteriorate the timing performance of the PET module.

Mesh:

Year:  2019        PMID: 31239430     DOI: 10.1088/1361-6560/ab2cb0

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.

Authors:  Andy LaBella; Xinjie Cao; Eric Petersen; Rick Lubinsky; Anat Biegon; Wei Zhao; Amir H Goldan
Journal:  J Nucl Med       Date:  2020-02-28       Impact factor: 10.057

2.  A high resolution and high detection efficiency depth-encoding detector for brain positron emission tomography based on a 0.75 mm pitch scintillator array.

Authors:  J Du; S R Cherry
Journal:  J Instrum       Date:  2021-05-20       Impact factor: 1.415

3.  Investigation of a Model-based Time-over-threshold Technique for Phoswich Crystal Discrimination.

Authors:  Haithem Bouziri; Catherine M Pepin; Konin Koua; Maher Benhouria; Caroline Paulin; Jinsong Ouyang; Marc Normandin; Jean-François Pratte; Georges El Fakhri; Roger Lecomte; Réjean Fontaine
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-05-04

4.  Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSO4 Reflector.

Authors:  Junwei Du
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-07-12

5.  Performance evaluation of dual-ended readout PET detectors based on BGO arrays with different reflector arrangements.

Authors:  Junwei Du; Qian Wang; Chih-Chieh Liu; Jinyi Qi; Simon R Cherry
Journal:  Phys Med Biol       Date:  2021-10-19       Impact factor: 4.174

6.  A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

Authors:  Junwei Du; Xiaowei Bai; Simon R Cherry
Journal:  Phys Med Biol       Date:  2020-08-19       Impact factor: 3.609

7.  High resolution detectors for whole-body PET scanners by using dual-ended readout.

Authors:  Zheng Liu; Ming Niu; Zhonghua Kuang; Ning Ren; San Wu; Longhan Cong; Xiaohui Wang; Ziru Sang; Crispin Williams; Yongfeng Yang
Journal:  EJNMMI Phys       Date:  2022-04-21

Review 8.  Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review.

Authors:  Haewook Park; Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-07-16
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.