Literature DB >> 31174845

Accuracy of biplane videoradiography for quantifying dynamic wrist kinematics.

Bardiya Akhbari1, Amy M Morton2, Douglas C Moore2, Arnold-Peter C Weiss2, Scott W Wolfe3, Joseph J Crisco4.   

Abstract

Accurately assessing the dynamic kinematics of the skeletal wrist could advance our understanding of the normal and pathological wrist. Biplane videoradiography (BVR) has allowed investigators to study dynamic activities in the knee, hip, and shoulder joint; however, currently, BVR has not been utilized for the wrist joint because of the challenges associated with imaging multiple overlapping bones. Therefore, our aim was to develop a BVR procedure and to quantify its accuracy for evaluation of wrist kinematics. BVR was performed on six cadaveric forearms for one neutral static and six dynamic tasks, including flexion-extension, radial-ulnar deviation, circumduction, pronation, supination, and hammering. Optical motion capture (OMC) served as the gold standard for assessing accuracy. We propose a feedforward tracking methodology, which uses a combined model of metacarpals (second and third) for initialization of the third metacarpal (MC3). BVR-calculated kinematic parameters were found to be consistent with the OMC-calculated parameters, and the BVR/OMC agreement had submillimeter and sub-degree biases in tracking individual bones as well as the overall joint's rotation and translation. All dynamic tasks (except pronation task) showed a limit of agreement within 1.5° for overall rotation, and within 1.3 mm for overall translations. Pronation task had a 2.1° and 1.4 mm limit of agreement for rotation and translation measurement. The poorest precision was achieved in calculating the pronation-supination angle, and radial-ulnar and volar-dorsal translational components, although they were sub-degree and submillimeter. The methodology described herein may assist those interested in examining the complexities of skeletal wrist function during dynamic tasks.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy study; Biplane videoradiography; Markerless tracking; Wrist kinematics

Mesh:

Year:  2019        PMID: 31174845      PMCID: PMC6612458          DOI: 10.1016/j.jbiomech.2019.05.040

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  In vivo kinematic behavior of the radio-capitate joint during wrist flexion-extension and radio-ulnar deviation.

Authors:  C P Neu; J J Crisco; S W Wolfe
Journal:  J Biomech       Date:  2001-11       Impact factor: 2.712

3.  Model-based tracking of the hip: implications for novel analyses of hip pathology.

Authors:  Daniel E Martin; Nicholas J Greco; Brian A Klatt; Vonda J Wright; William J Anderst; Scott Tashman
Journal:  J Arthroplasty       Date:  2010-03-26       Impact factor: 4.757

4.  Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Authors:  Michael J Bey; Roger Zauel; Stephanie K Brock; Scott Tashman
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

5.  Coordinate systems for the carpal bones of the wrist.

Authors:  James C Coburn; Mohammad A Upal; Joseph J Crisco
Journal:  J Biomech       Date:  2006-01-19       Impact factor: 2.712

6.  Measuring dynamic in-vivo glenohumeral joint kinematics: technique and preliminary results.

Authors:  Michael J Bey; Stephanie K Kline; Roger Zauel; Terrence R Lock; Patricia A Kolowich
Journal:  J Biomech       Date:  2007-11-09       Impact factor: 2.712

7.  X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research.

Authors:  Elizabeth L Brainerd; David B Baier; Stephen M Gatesy; Tyson L Hedrick; Keith A Metzger; Susannah L Gilbert; Joseph J Crisco
Journal:  J Exp Zool A Ecol Genet Physiol       Date:  2010-06-01

8.  Validation of three-dimensional model-based tibio-femoral tracking during running.

Authors:  William Anderst; Roger Zauel; Jennifer Bishop; Erinn Demps; Scott Tashman
Journal:  Med Eng Phys       Date:  2008-04-23       Impact factor: 2.242

9.  Carpal and forearm kinematics during a simulated hammering task.

Authors:  Evan L Leventhal; Douglas C Moore; Edward Akelman; Scott W Wolfe; Joseph J Crisco
Journal:  J Hand Surg Am       Date:  2010-07       Impact factor: 2.230

10.  Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion.

Authors:  Michael J Bey; Stephanie K Kline; Scott Tashman; Roger Zauel
Journal:  J Orthop Surg Res       Date:  2008-09-04       Impact factor: 2.359

View more
  9 in total

1.  Proximal-distal shift of the center of rotation in a total wrist arthroplasty is more than twice of the healthy wrist.

Authors:  Bardiya Akhbari; Amy M Morton; Kalpit N Shah; Janine Molino; Douglas C Moore; Arnold-Peter C Weiss; Scott W Wolfe; Joseph J Crisco
Journal:  J Orthop Res       Date:  2020-05-25       Impact factor: 3.494

2.  Total Wrist Arthroplasty Alignment and Its Potential Association with Clinical Outcomes.

Authors:  Bardiya Akhbari; Kalpit N Shah; Amy M Morton; Janine Molino; Douglas C Moore; Scott W Wolfe; Arnold-Peter C Weiss; Joseph J Crisco
Journal:  J Wrist Surg       Date:  2021-04-14

3.  Optical motion capture accuracy is task-dependent in assessing wrist motion.

Authors:  Brian McHugh; Bardiya Akhbari; Amy M Morton; Douglas C Moore; Joseph J Crisco
Journal:  J Biomech       Date:  2021-03-06       Impact factor: 2.712

4.  Biplanar Videoradiography to Study the Wrist and Distal Radioulnar Joints.

Authors:  Bardiya Akhbari; Amy M Morton; Douglas C Moore; Joseph J Crisco
Journal:  J Vis Exp       Date:  2021-02-04       Impact factor: 1.355

5.  Biomechanics of the Distal Radioulnar Joint During In Vivo Forearm Pronosupination.

Authors:  Bardiya Akhbari; Kalpit N Shah; Amy M Morton; Douglas C Moore; Arnold-Peter C Weiss; Scott W Wolfe; Joseph J Crisco
Journal:  J Wrist Surg       Date:  2021-02-04

6.  A Practical Guide to Measuring Ex vivo Joint Mobility Using XROMM.

Authors:  Armita R Manafzadeh
Journal:  Integr Org Biol       Date:  2020-11-12

7.  Finite element analysis of the performance of additively manufactured scaffolds for scapholunate ligament reconstruction.

Authors:  Nataliya Perevoshchikova; Kevin M Moerman; Bardiya Akhbari; Randy Bindra; Jayishni N Maharaj; David G Lloyd; Maria Gomez Cerezo; Amelia Carr; Cedryck Vaquette; David J Saxby
Journal:  PLoS One       Date:  2021-11-19       Impact factor: 3.240

8.  Automatic landmark detection and mapping for 2D/3D registration with BoneNet.

Authors:  Van Nguyen; Luis F Alves Pereira; Zhihua Liang; Falk Mielke; Jeroen Van Houtte; Jan Sijbers; Jan De Beenhouwer
Journal:  Front Vet Sci       Date:  2022-08-18

9.  The Reliability of Foot and Ankle Bone and Joint Kinematics Measured With Biplanar Videoradiography and Manual Scientific Rotoscoping.

Authors:  Jayishni N Maharaj; Sarah Kessler; Michael J Rainbow; Susan E D'Andrea; Nicolai Konow; Luke A Kelly; Glen A Lichtwark
Journal:  Front Bioeng Biotechnol       Date:  2020-03-10
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.