Literature DB >> 18434230

Validation of three-dimensional model-based tibio-femoral tracking during running.

William Anderst1, Roger Zauel, Jennifer Bishop, Erinn Demps, Scott Tashman.   

Abstract

The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquired after bead implantation. The subjects ran 2.5m/s on a treadmill positioned within a biplane radiographic system while images were acquired at 250 frames per second. Three-dimensional implanted bead locations were determined and used as a "gold standard" to measure the accuracy of the model-based tracking. The model-based tracking technique optimized the correlation between the radiographs acquired via the biplane X-ray system and digitally reconstructed radiographs created from the volume-rendered CT model. Accuracy was defined in terms of measurement system bias, precision and root-mean-squared (rms) error. Results were reported in terms of individual bone tracking and in terms of clinically relevant tibio-femoral joint translations and rotations (joint kinematics). Accuracy for joint kinematics was as follows: model-based tracking measured static joint orientation with a precision of 0.2 degrees or better, and static joint position with a precision of 0.2mm or better. Model-based tracking precision for dynamic joint rotation was 0.9+/-0.3 degrees , 0.6+/-0.3 degrees , and 0.3+/-0.1 degrees for flexion-extension, external-internal rotation, and ab-adduction, respectively. Model-based tracking precision when measuring dynamic joint translation was 0.3+/-0.1mm, 0.4+/-0.2mm, and 0.7+/-0.2mm in the medial-lateral, proximal-distal, and anterior-posterior direction, respectively. The combination of high-speed biplane radiography and volumetric model-based tracking achieves excellent accuracy during in vivo, dynamic knee motion without the necessity for invasive bead implantation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18434230      PMCID: PMC2668117          DOI: 10.1016/j.medengphy.2008.03.003

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  19 in total

1.  Abnormal rotational knee motion during running after anterior cruciate ligament reconstruction.

Authors:  Scott Tashman; David Collon; Kyle Anderson; Patricia Kolowich; William Anderst
Journal:  Am J Sports Med       Date:  2004-06       Impact factor: 6.202

2.  Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics.

Authors:  Guoan Li; Thomas H Wuerz; Louis E DeFrate
Journal:  J Biomech Eng       Date:  2004-04       Impact factor: 2.097

3.  Three-dimensional in vivo displacements of the shoulder complex from biplanar radiography.

Authors:  E Berthonnaud; G Herzberg; K D Zhao; K N An; J Dimnet
Journal:  Surg Radiol Anat       Date:  2005-03-24       Impact factor: 1.246

4.  In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

Authors:  Douglas A Dennis; Mohamed R Mahfouz; Richard D Komistek; William Hoff
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

Review 5.  Roentgen stereophotogrammetric analysis.

Authors:  G Selvik
Journal:  Acta Radiol       Date:  1990-03       Impact factor: 1.990

6.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.

Authors:  S A Banks; W A Hodge
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

7.  Three-dimensional instability of the anterior cruciate deficient knee.

Authors:  J Kärrholm; G Selvik; L G Elmqvist; L I Hansson; H Jonsson
Journal:  J Bone Joint Surg Br       Date:  1988-11

8.  A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs.

Authors:  L Lemieux; R Jagoe; D R Fish; N D Kitchen; D G Thomas
Journal:  Med Phys       Date:  1994-11       Impact factor: 4.071

9.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

10.  Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system.

Authors:  George R Hanson; Jeremy F Suggs; Andrew A Freiberg; Sridar Durbhakula; Guoan Li
Journal:  J Orthop Res       Date:  2006-05       Impact factor: 3.494

View more
  87 in total

1.  Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

Authors:  Shawn Farrokhi; Scott Tashman; Alexandra B Gil; Brian A Klatt; G Kelley Fitzgerald
Journal:  Clin Biomech (Bristol, Avon)       Date:  2011-11-08       Impact factor: 2.063

Review 2.  Dynamic knee laxity measurement devices.

Authors:  Mattias Ahldén; Yuichi Hoshino; Kristian Samuelsson; Paulo Araujo; Volker Musahl; Jón Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-31       Impact factor: 4.342

3.  Internal tibial rotation during in vivo, dynamic activity induces greater sliding of tibio-femoral joint contact on the medial compartment.

Authors:  Yuichi Hoshino; Scott Tashman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-25       Impact factor: 4.342

4.  The effects of limb alignment on anterior cruciate ligament graft tunnel positions estimated from plain radiographs.

Authors:  Carola F van Eck; Andrew K Wong; J J Irrgang; Freddie H Fu; Scott Tashman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

5.  Measuring Three-Dimensional Thorax Motion Via Biplane Radiographic Imaging: Technique and Preliminary Results.

Authors:  Timothy G Baumer; Joshua W Giles; Anne Drake; Roger Zauel; Michael J Bey
Journal:  J Biomech Eng       Date:  2016-01       Impact factor: 2.097

6.  Quantifying cross-scatter contamination in biplane fluoroscopy motion analysis systems.

Authors:  Janelle A Cross; Ben McHenry; Taly Gilat Schmidt
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-23

7.  Continuous cervical spine kinematics during in vivo dynamic flexion-extension.

Authors:  William J Anderst; William F Donaldson; Joon Y Lee; James D Kang
Journal:  Spine J       Date:  2013-11-07       Impact factor: 4.166

8.  Prediction and Validation of Load-Dependent Behavior of the Tibiofemoral and Patellofemoral Joints During Movement.

Authors:  Rachel L Lenhart; Jarred Kaiser; Colin R Smith; Darryl G Thelen
Journal:  Ann Biomed Eng       Date:  2015-04-28       Impact factor: 3.934

9.  Using relative velocity vectors to reveal axial rotation about the medial and lateral compartment of the knee.

Authors:  William J Anderst; Scott Tashman
Journal:  J Biomech       Date:  2009-12-14       Impact factor: 2.712

10.  Motion path of the instant center of rotation in the cervical spine during in vivo dynamic flexion-extension: implications for artificial disc design and evaluation of motion quality after arthrodesis.

Authors:  William Anderst; Emma Baillargeon; William Donaldson; Joon Lee; James Kang
Journal:  Spine (Phila Pa 1976)       Date:  2013-05-01       Impact factor: 3.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.