Background  Ulnar variance (UV) and center of rotation (COR) location at the level of the distal radioulnar joint (DRUJ) change with forearm rotation. Nevertheless, these parameters have not been assessed dynamically during active in vivo pronosupination. This assessment could help us to improve our diagnosis and treatment strategies. Questions/purposes  We sought to (1) mathematically model the UV change, and (2) determine the dynamic COR's location during active pronosupination. Methods  We used biplanar videoradiography to study DRUJ during in vivo pronation and supination in nine healthy subjects. UV was defined as the proximal-distal distance of ulnar fovea with respect to the radial sigmoid notch, and COR was calculated using helical axis of motion parameters. The continuous change of UV was evaluated using a generalized linear regression model. Results  A second-degree polynomial with R 2 of 0.85 was able to model the UV changes. Maximum negative UV occurred at 38.0 degrees supination and maximum positive UV occurred at maximum pronation. At maximum pronation, the COR was located 0.5 ± 1.8 mm ulnarly and 0.6 ± 0.8 mm volarly from the center of the ulnar fovea, while at maximum supination, the COR was located 0.2 ± 0.6 mm radially and 2.0 ± 0.5 mm volarly. Conclusion  Changes in UV and volar translation of the COR are nonlinear at the DRUJ during pronosupination. Clinical Relevance  Understanding the dynamic nature of UV as a function of pronosupination can help guide accurate evaluation and treatment of wrist pathology where the UV is an important consideration. The dynamic behavior of COR might be useful in designing DRUJ replacement implants to match the anatomical motion. Thieme. All rights reserved.

Entities:  

Keywords:  DRUJ; center of rotation; kinematics; radioulnar joint; ulnar variance

Year:  2021        PMID: 34109063      PMCID: PMC8169167          DOI: 10.1055/s-0040-1722334

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  42 in total

1.  The Scheker distal radioulnar joint arthroplasty to unravel a virtually unsolvable problem.

Authors:  Ilse Degreef; Luc De Smet
Journal:  Acta Orthop Belg       Date:  2013-04       Impact factor: 0.500

2.  The influence of the axial, antero-posterior and lateral positions of the center of rotation of a ball-and-socket disc prosthesis on the cervical spine biomechanics.

Authors:  Fabio Galbusera; Federica Anasetti; Chiara Maria Bellini; Francesco Costa; Maurizio Fornari
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-02-10       Impact factor: 2.063

3.  A mathematical approach for three-dimensional analysis of the mechanics of the spine.

Authors:  M Panjabi; A A White
Journal:  J Biomech       Date:  1971-05       Impact factor: 2.712

4.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques.

Authors:  Daniel L Miranda; Joel B Schwartz; Andrew C Loomis; Elizabeth L Brainerd; Braden C Fleming; Joseph J Crisco
Journal:  J Biomech Eng       Date:  2011-12       Impact factor: 2.097

5.  Ulnar variance: correlation of plain radiographs, computed tomography, and magnetic resonance imaging with anatomic dissection.

Authors:  Daniel K Laino; Catherine N Petchprapa; Steve K Lee
Journal:  J Hand Surg Am       Date:  2011-11-25       Impact factor: 2.230

6.  Effects of forearm rotation on the clinical evaluation of ulnar variance.

Authors:  G L Yeh; P K Beredjiklian; M A Katz; D R Steinberg; D J Bozentka
Journal:  J Hand Surg Am       Date:  2001-11       Impact factor: 2.230

7.  Proximal-distal shift of the center of rotation in a total wrist arthroplasty is more than twice of the healthy wrist.

Authors:  Bardiya Akhbari; Amy M Morton; Kalpit N Shah; Janine Molino; Douglas C Moore; Arnold-Peter C Weiss; Scott W Wolfe; Joseph J Crisco
Journal:  J Orthop Res       Date:  2020-05-25       Impact factor: 3.494

8.  Ulnar variance--the effect of wrist positioning and roentgen filming technique.

Authors:  R A Epner; W H Bowers; W B Guilford
Journal:  J Hand Surg Am       Date:  1982-05       Impact factor: 2.230

9.  The triangular fibrocartilage complex of the wrist--anatomy and function.

Authors:  A K Palmer; F W Werner
Journal:  J Hand Surg Am       Date:  1981-03       Impact factor: 2.230

10.  Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion.

Authors:  Michael J Bey; Stephanie K Kline; Scott Tashman; Roger Zauel
Journal:  J Orthop Surg Res       Date:  2008-09-04       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.