Pulsed xenon ultraviolet and non-thermal atmospheric plasma treatments are effective for the disinfection of air in hospital blood sampling rooms.

Shan-Ni Wang1, Jing-Jing Li1, Ying-Xin Liu2, Zhi Lin2, Jiao-Jiao Qiao1, Li-Hua Chen3, Yu Li3, Yong Wu3, Mei-Mei Wang1, Yun-Bo Liu4, Chen Yan5, Zhi-Heng Chen6, Chang-Qing Gao7.   

Abstract

BACKGROUND AND OBJECTIVES: Non-thermal atmospheric plasma treatment and pulsed xenon ultraviolet (PX-UV) treatment are widely used in disinfection of hospital environments. However, their effectiveness has not been evaluated against a comparator. The objective of this study is to evaluate their effectiveness in the disinfection of pathogens in the air in hospital blood sampling rooms.
METHODS: Samples were taken from the air before and after disinfection with PX-UV and non-thermal atmospheric plasma. We counted bacterial colonies and identified the types of bacteria.
RESULTS: Non-thermal plasma treatment significantly reduced bacterial counts in the air, the median reduced from 1 before treatment to zero afterwards (p = 0.03). PX-UV treatment also significantly reduced bacterial counts in the air (p = 0.01), the median reduced from 1.5 before treatment to zero afterwards. Pathogens identified in the current study include nosocomial bacteria, such as Staphylococcus aureus, Staphylococcus epidermidis, and yeast.
CONCLUSION: Disinfection of blood sampling sites is essential in a health service department. The efficiency of PX-UV and non-thermal atmospheric plasma treatment are comparable in air disinfection.
Copyright © 2019 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hospital disinfection; Non-thermal atmospheric plasma; Nosocomial infection; Pulsed xenon ultraviolet; Sterilization

Mesh:

Substances:

Year:  2019        PMID: 31152875      PMCID: PMC7105215          DOI: 10.1016/j.pdpdt.2019.05.034

Source DB:  PubMed          Journal:  Photodiagnosis Photodyn Ther        ISSN: 1572-1000            Impact factor:   3.631


Introduction

Hospitals are a source of cross infection [1,2]. This was demonstrated in 2003 by the epidemic of severe acute respiratory syndrome (SARS) in which 128 subjects were infected by a SARS patient who sat in the emergency department of a community hospital awaiting assignment to a hospital bed [1]. A simulated study showed that, due to the length of contact, the cross infection risk between health workers is greater than between patients or between patients and health workers [2]. To make matters worse, a hospital environment is widely contaminated by multidrug resistant organisms [3,4]. Therefore, it is critical to disinfect hospital environments to control cross infection. The effect of manual cleaning is variable and cleaning is often incomplete even after an intervention to improve cleaning methods [5]. Medical devices used by multiple patients are often inadequately cleaned by manual measures [6]. Therefore automated cleaning systems, such as pulsed xenon ultraviolet (PX-UV), are innovations designed to disinfect hospital environments of different settings, such as wards [[7], [8], [9], [10], [11]], burns units [12], milk feed preparation rooms [13], operation rooms [14,15], surgical sites [16,17], nursing homes [18], long-term acute care facilities [19], isolation rooms [20], and community hospitals [21,22]. Non-thermal atmospheric plasma treatment is also used in prevention of nosocomial infections and other fields, including inactivation of dermatophyte infections in animal models, prevention of bacterial colonization on surgical sutures, and prevention of surgical site infection [[23], [24], [25], [26]], However, the effect is variable [24,27]. Health check-ups, disease prevention, and chronic disease management are an increasingly important subject. The health check-up clinic of the Third XiangYa Hospital sees more than 200 people each day. Blood sampling, an invasive procedure, is essential for the majority of people attending for evaluation. Disinfection of the blood sampling room is therefore important. However, no comparative study has yet compared the effectiveness of disinfection with PX-UV treatment and non-thermal atmospheric plasma treatment. Here, we compare these two automated methods of disinfecting a blood sampling room.

Materials and methods

Sampling

Sampling sites: This study was conducted in the blood sampling room of the Health Management Center of the Third XiangYa Hospital. The size of the room is 6 m x 6 m. Blood sampling tables are placed in the center of the room. We measured pathogens in the air of the room. Five plates were used in the analysis of air study. We repeated the PX-UV experiment twice and the non-thermal atmospheric plasma treatment study three times. We did this because a parallel study of the evaluation of the disinfecting effect of PX-UV on a laboratory animal facility showed that PX-UV is effective at sterilizing and the results have been submitted for publication. Due to errors in sampling, one sample using non-thermal atmospheric plasma treatment was missed. Therefore, the total number of samples analysed was 14 instead of 15. Sampling time: Samples were taken in the afternoon of the working day at about 2:30 pm before automated disinfection, and then repeated immediately after disinfection. Sampling methods: For the sampling, 64 cm2 tryptic soy agar plates were left open for 30 min. while the control plates were open and covered immediately. Other procedures were the same for both sets of plates.

Culture count results

The bacterial colonies on each plate were counted and the types of bacteria were classified with matrix-assisted laser desorption/ionization time of flight mass spectrometry (MicroflexLT/SH. BRUKER, Germany). For the surface study, the colony form unit (CFU)/cm2 is the number of colonies counted on each plate. For the air pathogen culture, results were reported as total CFU per plate. When CFU was over 100 per plate, results were reported as 100.

Device

The disinfectant efficacy of the PX-UV machine MX-3600 (Xi’An Fukang Air Purification Equipment and Engineering Co. Ltd, Xi’an, China) was initially assessed and we found that it was set at a wavelength of 100 nm–400 nm, a frequency at 3 Hz, and a duration of work of 6 min, its efficacy was 100% for Staphylococcus aureus and Escherichia coli. Thus, these parameters were used for this study. The machine was deployed on the floor in the center of the room. Hence, all the air in the room is exposed to UV light. A non-thermal atmospheric plasma sterilization machine LK/JKF-Y100 (Chengdu Laokan Medical Technology Co., Ltd, Chengdu, China) is routinely used for disinfection each day by the center after blood sampling. During operation, plasma is formed inside the machine and air is sterilized as it passes through the plasma. With air circulating in the room for some time, all of the air in the room should be disinfected. During the study, the machine was placed in the same position as the PX-UV machine of the room, operated as usual, and turned on for 2 h. Samples were collected as in the PX-UV disinfection study.

Statistical analysis

Data were pooled from the studies and analyzed by performing a Mann-Whitney rank sum test, using MedCalc (version 17) statistical analysis software (MedCalc Software, Ostend, Belgium), to compare the difference between the data before and after disinfection. Threshold statistical significance was set at p<0.05.

Results

Disinfectant effect of two machines on the air

As shown in Table 1 A, non-thermal atmospheric plasma treatment can significantly reduce bacterial colony counts (Mann-Whitney U = 55.50, p = 0.03), the median CFU/cm2 of 1 before treatment reduced to 0 after treatment. PX-UV reduces bacterial colony counts ((Mann-Whitney U = 17.5, p = 0.01), with the median of CFU/cm2 being 1.5 before treatment reduced to 0 after treatment (Table 1B).
Table 1

Comparison of colony counts before and after plasma treatment and after PX-UV disinfection on air.

A
Before plasma treatment on airAfter plasma treatment on air 
no. samplesMedian (95% CV)lowest - highest valuesno. samplesMedian (95% CV)lowest - highest valuesP
141 (0.89 – 1.00)0.00 - 6.00140 (0.00 - 1.00)0.00 - 2.000.03
Comparison of colony counts before and after plasma treatment and after PX-UV disinfection on air.

Pathogens identified in air disinfection study

As shown in Table 2 , 30 types of bacteria were identified in the air disinfection study. Of these, 17 pathogens were identified in the non-thermal atmospheric plasma treatment study; 15 were found before treatment and two were found after treatment. In the PX-UV study, 15 pathogens were identified; 11 were identified before treatment and 4 after treatment. Two bacteria (Micrococcus luteus and Staphylococcus hominis, Table 2) were common to both studies.
Table 2

Comparison of the bacteria species using plasma treatment and PX-UV disinfection on air.

Name of the bacteria identified in the airStainingSpecies identified before plasma treatmentSpecies identified after plasma treatmentSpecies identified before PX-UVSpecies identified after PX-UV
Acinetobacter calcoaceticusG-+
Bacillus galactosidilyticusG++
Bacillus megateriumG++
Exiguobacterium aurantiacumG++
Flavobacterium flevenseG-+
Flavobacterium gelidilacusG-+
Kocuria marinaG++
Lactobacillus crispatusG++
Lactobacillus fuchuensisG++
Lactobacillus ingluvieiG++
Lactobacillus maliG++
Methylobacterium extorquensG-+
Methylobacterium organophilumG-+
Micrococcus luteusG+++
Micrococcus lylaeG++
Pseudomonas monteiliiG-+
Pseudomonas poaeG-+
Pseudomonas veroniiG-+
Rhizobium radiobacterG-+
Sphingomonas aerolataG-+
Staphylococcus arlettaeG++
Staphylococcus capitisG++
Staphylococcus epidermidisG++
Staphylococcus epidermidisG+++
Staphylococcus equorumG++
Staphylococcus hominisG+++
Staphylococcus kloosiiG++
Staphylococcus lugdunensisG++
Streptococcus pneumoniaeG++
Streptococcus pseudopneumoniaeG++

G+: Gram Positive, G-: Gram Negative.

+: organism present, - : organism absent.

Comparison of the bacteria species using plasma treatment and PX-UV disinfection on air. G+: Gram Positive, G-: Gram Negative. +: organism present, - : organism absent.

Discussion

In our study, we found that both PX-UV treatment and non-thermal atmospheric plasma treatment can significantly reduce air pathogen counts and their effects are comparable. Some of the pathogens identified in our study commonly cause nosocomial infections. Nosocomial infection is a worldwide issue that needs to be addressed [1,2]. An investigation in China showed that 1245 patients were diagnosed with a nosocomial infection among 24,390 hospital inpatients [28]. Another study investigated 914 elderly inpatients in a department of gerontology and found that 10% of the patients suffered from nosocomial infection [29]. A study in a hospitalized neonatal intensive care unit found 9% of patients with nosocomial infections [30]. The bacteria identified in this study include those that often cause nosocomial infections, such as Staphylococcus aureus [31,32]. Yeasts [32], Staphylococcus epidermidis [30,33,34]. Staphylococcus aureus and Staphylococcus epidermidis are often resistant to multidrug treatment [35,36]. As so few bacteria were identified in each plate we decided against testing them for resistance to antibiotics. Instead we used the published literature as a reference. Therefore, the percentage of drug resistant bacteria in the study is unknown. Health management and disease prevention play an important role in reducing catastrophic expenditure and the economic burden of society [37]. Cultural and social issues are implicated in the process of chronic disease development, and hence are pivotal to prevention [38]. In China, health examination often involves blood sampling. Taking blood samples is an invasive procedure and is a risk for transmitting nosocomial infections. Indeed, bacteremia is one of the most frequent forms of nosocomial infection [30]. Staphylococcus aureus bacteremia is often a serious threat to health [39]. Our study shows that disinfection of the blood sampling environment is important in prevention of nosocomial infections, such as with S. aureus. Non-thermal plasma is a gas that is partially ionized with its energy being stored mostly in free electrons, which can be generated by various electric discharges, such as corona discharges, dielectric barrier discharge, gliding arc, electrospray, plasma jets, and so forth [40,41]. Its biological effects are the results of the effect of heat, ultraviolet radiation, reactive species, and that of charged particles [42]. The types of bacteria identified in the non-thermal atmospheric plasma treatment study in the air were greater than in the study of PX-UV treatment. This is probably caused by two factors. First, plasma treatment was repeated three times, while PX-UV treatment was repeated twice. Second, the total number of people visiting clinic on the days that plasma treatment was used was nearly double than that of the days PX-UV was used. Hence, more types of bacteria were probably brought into the clinic. In both PX-UV and non-thermal plasma treatment studies, new bacterial species were identified after treatment. These were most likely brought into the room by the automatic ventilation system which was running throughout. Taken together, our study shows that disinfection of blood sampling sites in a health management department is essential, and PX-UV and non-thermal atmospheric plasma treatment are comparable in killing air-borne pathogens.

Author contributions

C.Q.G., Z.H.C., Y.C., and Y.B.L., conceptualized the study and wrote the manuscript. S.N.W., J.J.L., Y.X.L., Z.L., J.J.Q., L.H.C, Y.L., Y.W., and M.M.W conducted the experiments. All authors reviewed the manuscript.

Ethics approval

Not required.

Competing interests

The authors declare no competing interests.
  33 in total

Review 1.  Nonthermal plasma--A tool for decontamination and disinfection.

Authors:  Vladimir Scholtz; Jarmila Pazlarova; Hana Souskova; Josef Khun; Jaroslav Julak
Journal:  Biotechnol Adv       Date:  2015-01-13       Impact factor: 14.227

2.  The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital.

Authors:  Joanne Levin; Linda S Riley; Christine Parrish; Daniel English; Sehoon Ahn
Journal:  Am J Infect Control       Date:  2013-05-16       Impact factor: 2.918

Review 3.  Staphylococcus epidermidis as a cause of bacteremia.

Authors:  Sharon Kleinschmidt; Flavia Huygens; Joan Faoagali; Irani U Rathnayake; Louise M Hafner
Journal:  Future Microbiol       Date:  2015-10-30       Impact factor: 3.165

4.  Nosocomial infections in medical intensive care units in the United States. National Nosocomial Infections Surveillance System.

Authors:  M J Richards; J R Edwards; D H Culver; R P Gaynes
Journal:  Crit Care Med       Date:  1999-05       Impact factor: 7.598

5.  Reduced nosocomial infection rate in a neonatal intensive care unit during a 4-year surveillance period.

Authors:  Yong-Chuan Chen; Chen-Fu Lin; Yun-Jiau Fuh Rehn; Juei-Chao Chen; Po-Yen Chen; Chao-Huei Chen; Teh-Ming Wang; Fang-Liang Huang
Journal:  J Chin Med Assoc       Date:  2017-05-03       Impact factor: 2.743

6.  Interaction of healthcare worker hands and portable medical equipment: a sequence analysis to show potential transmission opportunities.

Authors:  Chetan Jinadatha; Frank C Villamaria; John D Coppin; Charles R Dale; Marjory D Williams; Ryan Whitworth; Mark Stibich
Journal:  BMC Infect Dis       Date:  2017-12-28       Impact factor: 3.090

7.  Evaluation of an ultraviolet room disinfection protocol to decrease nursing home microbial burden, infection and hospitalization rates.

Authors:  Christine R Kovach; Yavuz Taneli; Tammy Neiman; Elaine M Dyer; Alvin Jason A Arzaga; Sheryl T Kelber
Journal:  BMC Infect Dis       Date:  2017-03-03       Impact factor: 3.090

8.  The Risk of Cross Infection in the Emergency Department: A Simulation Study.

Authors:  Vicki Stover Hertzberg; Yuke A Wang; Lisa K Elon; Douglas W Lowery-North
Journal:  Infect Control Hosp Epidemiol       Date:  2018-04-16       Impact factor: 3.254

9.  Reduction of Clostridium Difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods.

Authors:  Brittany C Eckstein; Daniel A Adams; Elizabeth C Eckstein; Agam Rao; Ajay K Sethi; Gopala K Yadavalli; Curtis J Donskey
Journal:  BMC Infect Dis       Date:  2007-06-21       Impact factor: 3.090

10.  Sterilization of Biofilm on a Titanium Surface Using a Combination of Nonthermal Plasma and Chlorhexidine Digluconate.

Authors:  Tripti Thapa Gupta; Surya B Karki; Jyl S Matson; Daniel J Gehling; Halim Ayan
Journal:  Biomed Res Int       Date:  2017-09-19       Impact factor: 3.411

View more
  3 in total

1.  A Practical Assessment of the Disinfectant Efficacy of UV Light with and without Ozone Using a Novel Transfer Hatch in a Research Animal Facility.

Authors:  Jiao-Jiao Qiao; Jing-Jing Li; Chun-Hui Li; Yong Qi; Li-Yu Chen; Shan-Ni Wang; Paul E Honess; Yun-Bo Liu; Chen Zhang; Qing-Xia Liu; Bin Yi; Chang-Qing Gao
Journal:  J Am Assoc Lab Anim Sci       Date:  2022-04-07       Impact factor: 1.706

2.  Portable pulsed xenon ultraviolet light disinfection in a teaching hospital animal laboratory in China.

Authors:  Jing-Jing Li; Shan-Ni Wang; Jiao-Jiao Qiao; Li-Hua Chen; Yu Li; Yong Wu; Yan-Xia Ding; Mei-Mei Wang; Yun Tian; Yun-Bo Liu; Chen Yan; Chen Zhang; Chang-Qing Gao
Journal:  J Photochem Photobiol B       Date:  2020-04-06       Impact factor: 6.252

3.  Application Effect of the 6S Care Model in Sterilization in the Department of Stomatology and Its Impact on the Incidence of Nosocomial Infection.

Authors:  Jing Lou; Guiqin Wang; Man Jiang; Guochao Xu
Journal:  Emerg Med Int       Date:  2022-07-18       Impact factor: 1.621

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.