| Literature DB >> 31149355 |
Xiaoying Cai1, Xianhui Ding2, Wenbin Wang2, Ke Yang2, Zhiming Zhou2, Yannan Fang3, XiaoLei Shi3,2.
Abstract
OBJECTIVE: Mechanical thrombectomy is recommended for acute ischemic stroke (AIS) with large artery occlusion. Radiation during the endovascular procedure would increase the risk of skin diseases. We sought to identify radiation outcomes during mechanical thrombectomy.Entities:
Keywords: mechanical thrombectomy; occlusion; stroke
Year: 2019 PMID: 31149355 PMCID: PMC6534054 DOI: 10.1515/tnsci-2019-0002
Source DB: PubMed Journal: Transl Neurosci ISSN: 2081-6936 Impact factor: 1.757
Baseline information of the study. y, year; HT, hypertension; DM, diabetes mellitus; AF, arterial fibrillation; NIHSS, National Institute Health Stroke Scale.
| Variables | All |
|---|---|
| No. | 41 |
| Age (y) | 68.73 ± 11.05 |
| Male | 23 |
| Smoke | 13 |
| Alcohol | 12 |
| HT | 27 |
| DM | 10 |
| AF | 27 |
| Hyperglycemia | 12 |
| Arch type | |
| Ⅰ | 12 |
| Ⅱ | 19 |
| Ⅲ | 10 |
| NIHSS | 15.66 ± 5.94 |
Endovascular treatment details of the participants. ICA, internal carotid artery; MCA, middle cerebral artery.
| Variable | No. |
|---|---|
| ICA | 11 |
| MCA | 27 |
| Posterior circulation | 3 |
Endovascular treatment details of all patients. min, minute; s, second; ICA, internal carotid artery; MCA, middle cerebral artery; KAP, kerma area product.
| Time | Dose | ||||||
|---|---|---|---|---|---|---|---|
| Variable | Operation duration (min) | Angiographic run (s) | Fluoroscopy (min) | KAP (Gy- cm2) | Angiographic run (mGy) | Fluoroscopy (mGy) | Cumulative (mGy) |
| All | 84.45 ± 31.66 | 129.71 ± 81.14 | 16.02 ± 11.03 | 26519.68 ± 9502.81 | 1276.43 ± 1647.56 | 607.26 ± 412.34 | 1635.52 ± 593.65 |
| Site | |||||||
| ICA | 79.95 ± 14.43 | 151.93 ± 127.46 | 13.28 ± 4.01 | 23828.00 ± 7348.11 | 1969.34 ± 3119.98 | 477.63 ± 180.10 | 1520.69 ± 311.00 |
| MCA | 84.29 ± 34.58 | 125.73 ± 58.37 | 15.19 ± 10.21 | 26279.70 ±8662.80 | 1031.08 ± 370.60 | 585.35 ± 351.24 | 1616.95 ± 614.17 |
| Posterior | 102.36 ± 53.59 | 83.99 ± 8.56 | 33.59 ± 22.04 | 38549.00 ± 17402.26 | 943.93 ± 461.55 | 1279.73 ± 925.88 | 2223.67 ± 1032.03 |
The association between NIHSS and endovascular procedure parameters. KAP, kerma area product.
| P1 | P2 | |
|---|---|---|
| Operation duration (min) | 0.487 | 0.671 |
| Angiographic run (s) | 0.109 | 0.919 |
| Fluoroscopy (min) | 0.494 | 0.707 |
| KAP (Gy-cm2) | 0.822 | 0.883 |
| Angiographic run (mGy) | 0.398 | 0.085 |
| Fluoroscopy (mGy) | 0.653 | 0.607 |
| Cumulative (mGy) | 0.946 | 0.530 |