Fabrication of Low-Cost Patient-Specific Vascular Models for Particle Image Velocimetry.

Katrina L Ruedinger1,2, Rafael Medero3,2, Alejandro Roldán-Alzate4,5,6.   

Abstract

PURPOSE: Particle image velocimetry (PIV), an in vitro experimentation technique that optically measures velocity components to analyze fluid velocity fields, has become increasingly popular to study flow dynamics in various vascular territories. However, it can be difficult and expensive to create patient-specific clear models for PIV due to the importance of refractive index matching of the model and the fluid. We aim to implement and test the use of poly-vinyl alcohol (PVA) in a lost-core casting technique to create low-cost, patient-specific models for PIV.
METHODS: Anonymized patient vascular anatomies were segmented and processed in Mimics/3Matic to create patient-specific cores from 3D digital subtraction angiographies. The cores were 3D-printed with PVA and post-processed with a 80:20 water:glue mixture to smooth the surface. Two silicones, Sylgard 184 and Solaris, were used to encapsulate the model and the PVA core was dissolved using warm water. Computed tomography scans were used to evaluate geometric accuracy using circumferences and surface differences in the model.
RESULTS: Mean geometric differences in circumference along the inlet centerline and the mean surface difference in the aneurysm between the final Silicone Model and the desired STL Print geometry were statistically insignificant (0.6 mm, 95% CI [- 1.4, 2.8] and 0.3 mm 95% CI [- 0.1, 0.7], respectively). Particle illumination within each model was successful. The cost of one 10 cm × 10 cm × 5 cm model was $69.
CONCLUSION: This technique was successful to implement and test the use of PVA in a lost-core casting technique to create low-cost, patient-specific in vitro models for PIV experimentation.

Entities:  

Keywords:  3D printing; Compliant vascular model; Particle image velocimetry; Patient-specific

Mesh:

Substances:

Year:  2019        PMID: 31098919      PMCID: PMC7877060          DOI: 10.1007/s13239-019-00417-2

Source DB:  PubMed          Journal:  Cardiovasc Eng Technol        ISSN: 1869-408X            Impact factor:   2.495


  10 in total

1.  Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch.

Authors:  Marco Laumen; Tim Kaufmann; Daniel Timms; Peter Schlanstein; Sebastian Jansen; Shaun Gregory; Kai Chun Wong; Thomas Schmitz-Rode; Ulrich Steinseifer
Journal:  Artif Organs       Date:  2010-10       Impact factor: 3.094

2.  A new production method of elastic silicone carotid phantom based on MRI acquisition using rapid prototyping technique.

Authors:  Peng Cao; Yvan Duhamel; Guillaume Olympe; Bruno Ramond; Francois Langevin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

3.  In vitro flow investigations in the aortic arch during cardiopulmonary bypass with stereo-PIV.

Authors:  Martin Büsen; Tim A S Kaufmann; Michael Neidlin; Ulrich Steinseifer; Simon J Sonntag
Journal:  J Biomech       Date:  2015-04-03       Impact factor: 2.712

Review 4.  A Review of Arterial Phantom Fabrication Methods for Flow Measurement Using PIV Techniques.

Authors:  Sina G Yazdi; P H Geoghegan; P D Docherty; Mark Jermy; Adib Khanafer
Journal:  Ann Biomed Eng       Date:  2018-07-09       Impact factor: 3.934

5.  MRI-based modeling of spleno-mesenteric confluence flow.

Authors:  David R Rutkowski; Rafael Medero; Felix J Garcia; Alejandro Roldán-Alzate
Journal:  J Biomech       Date:  2019-03-23       Impact factor: 2.712

6.  Impact of image reconstruction parameters when using 3D DSA reconstructions to measure intracranial aneurysms.

Authors:  Katrina L Ruedinger; David R Rutkowski; Sebastian Schafer; Alejandro Roldán-Alzate; Erick L Oberstar; Charles Strother
Journal:  J Neurointerv Surg       Date:  2017-04-06       Impact factor: 5.836

7.  Experimental insights into flow impingement in cerebral aneurysm by stereoscopic particle image velocimetry: transition from a laminar regime.

Authors:  Takanobu Yagi; Ayaka Sato; Manabu Shinke; Sara Takahashi; Yasutaka Tobe; Hiroyuki Takao; Yuichi Murayama; Mitsuo Umezu
Journal:  J R Soc Interface       Date:  2013-02-20       Impact factor: 4.118

8.  In vitro non-rigid life-size model of aortic arch aneurysm for endovascular prosthesis assessment.

Authors:  Abdulrazzaq Sulaiman; Loîc Boussel; Frédéric Taconnet; Jean Michel Serfaty; Hasan Alsaid; Cherif Attia; Laurent Huet; Philippe Douek
Journal:  Eur J Cardiothorac Surg       Date:  2007-11-28       Impact factor: 4.191

Review 9.  MRI segmentation of the human brain: challenges, methods, and applications.

Authors:  Ivana Despotović; Bart Goossens; Wilfried Philips
Journal:  Comput Math Methods Med       Date:  2015-03-01       Impact factor: 2.238

10.  Manufacturing of microcirculation phantoms using rapid prototyping technologies.

Authors:  Anthony Buchoux; Prashant Valluri; Stewart Smith; Adam A Stokes; Peter R Hoskins; Vassilis Sboros
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2015
  10 in total
  9 in total

1.  In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV.

Authors:  Rafael Medero; Katrina Ruedinger; David Rutkowski; Kevin Johnson; Alejandro Roldán-Alzate
Journal:  Ann Biomed Eng       Date:  2020-06-10       Impact factor: 3.934

2.  Patient-specific brain arteries molded as a flexible phantom model using 3D printed water-soluble resin.

Authors:  Daniel P G Nilsson; Madelene Holmgren; Petter Holmlund; Anders Wåhlin; Anders Eklund; Tobias Dahlberg; Krister Wiklund; Magnus Andersson
Journal:  Sci Rep       Date:  2022-06-17       Impact factor: 4.996

3.  Enhancement of cerebrovascular 4D flow MRI velocity fields using machine learning and computational fluid dynamics simulation data.

Authors:  David R Rutkowski; Alejandro Roldán-Alzate; Kevin M Johnson
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.379

4.  A phantom study comparing radial trajectories for accelerated cardiac 4D flow MRI against a particle imaging velocimetry reference.

Authors:  Philip A Corrado; Rafael Medero; Kevin M Johnson; Christopher J François; Alejandro Roldán-Alzate; Oliver Wieben
Journal:  Magn Reson Med       Date:  2021-02-05       Impact factor: 3.737

Review 5.  Imaging Modalities for Intracranial Aneurysm: More Than Meets the Eye.

Authors:  Clémence Maupu; Héloïse Lebas; Yacine Boulaftali
Journal:  Front Cardiovasc Med       Date:  2022-02-15

Review 6.  A Review on Novel Channel Materials for Particle Image Velocimetry Measurements-Usability of Hydrogels in Cardiovascular Applications.

Authors:  Christina Maria Winkler; Antonia Isabel Kuhn; Gesine Hentschel; Birgit Glasmacher
Journal:  Gels       Date:  2022-08-12

7.  Design and validation of a modular micro-robotic system for the mechanical characterization of soft tissues.

Authors:  Andrea Acuna; Julian M Jimenez; Naomi Deneke; Sean M Rothenberger; Sarah Libring; Luis Solorio; Vitaliy L Rayz; Chelsea S Davis; Sarah Calve
Journal:  Acta Biomater       Date:  2021-07-21       Impact factor: 10.633

Review 8.  Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis.

Authors:  Vitaliy L Rayz; Aaron A Cohen-Gadol
Journal:  Annu Rev Biomed Eng       Date:  2020-03-25       Impact factor: 11.324

9.  Development of Custom Wall-Less Cardiovascular Flow Phantoms with Tissue-Mimicking Gel.

Authors:  Megan E Laughlin; Sam E Stephens; Jamie A Hestekin; Morten O Jensen
Journal:  Cardiovasc Eng Technol       Date:  2021-06-02       Impact factor: 2.495

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.