Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch.

Marco Laumen1, Tim Kaufmann, Daniel Timms, Peter Schlanstein, Sebastian Jansen, Shaun Gregory, Kai Chun Wong, Thomas Schmitz-Rode, Ulrich Steinseifer.   

Abstract

Tip geometry and placement of rotary blood pump inflow and outflow cannulae influence the dynamics of flow within the ventricle and aortic branch. Cannulation, therefore, directly influences the potential for thrombus formation and end-organ perfusion during ventricular assist device (VAD) support or cardiopulmonary bypass (CPB). The purpose of this study was to investigate the effect of various inflow/outflow cannula tip geometries and positions on ventricular and greater vessel flow patterns to evaluate ventricular washout and impact on cerebral perfusion. Transparent models of a dilated cardiomyopathic ventricle and an aortic branch were reconstructed from magnetic resonance imaging data to allow flow measurements using particle image velocimetry (PIV). The contractile function of the failing ventricle was reproduced pneumatically, and supported with a rotary pump. Flow patterns were visualized around VAD inflow cannulae, with various tip geometries placed in three positions in the ventricle. The outflow cannula was placed in the subclavian artery and at several positions in the aorta. Flow patterns were measured using PIV and used to validate an aortic flow computational fluid dynamic study. The PIV technique indicated that locating the inflow tip in the left ventricular outflow tract improved complete ventricular washout while the tip geometry had a smaller influence. However, side holes in the inflow cannula improved washout in all cases. The PIV results confirmed that the positioning and orientation of the outflow cannula in the aortic branch had a high impact on the flow pattern in the vessels, with a negative blood flow in the right carotid artery observed in some cases. Cannula placement within the ventricle had a high influence on chamber washout. The positioning of the outflow cannula directly influences the flow through the greater vessels, and may be responsible for the occasional reduction in cerebral perfusion seen in clinical CPB.
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20964698     DOI: 10.1111/j.1525-1594.2010.01098.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  9 in total

1.  Small Left Ventricular Size Is an Independent Risk Factor for Ventricular Assist Device Thrombosis.

Authors:  Venkat Keshav Chivukula; Jennifer A Beckman; Anthony R Prisco; Shin Lin; Todd F Dardas; Richard K Cheng; Stephen D Farris; Jason W Smith; Nahush A Mokadam; Claudius Mahr; Alberto Aliseda
Journal:  ASAIO J       Date:  2019-02       Impact factor: 2.872

2.  Fabrication of Low-Cost Patient-Specific Vascular Models for Particle Image Velocimetry.

Authors:  Katrina L Ruedinger; Rafael Medero; Alejandro Roldán-Alzate
Journal:  Cardiovasc Eng Technol       Date:  2019-05-16       Impact factor: 2.495

Review 3.  3D Printing for Cardiovascular Applications: From End-to-End Processes to Emerging Developments.

Authors:  Ramtin Gharleghi; Claire A Dessalles; Ronil Lal; Sinead McCraith; Kiran Sarathy; Nigel Jepson; James Otton; Abdul I Barakat; Susann Beier
Journal:  Ann Biomed Eng       Date:  2021-05-17       Impact factor: 3.934

4.  Understanding the influence of left ventricular assist device inflow cannula alignment and the risk of intraventricular thrombosis.

Authors:  Michael Neidlin; Sam Liao; Zhiyong Li; Benjamin Simpson; David M Kaye; Ulrich Steinseifer; Shaun Gregory
Journal:  Biomed Eng Online       Date:  2021-05-11       Impact factor: 2.819

5.  Effects of Cone-Shaped Bend Inlet Cannulas of an Axial Blood Pump on Thrombus Formation: An Experiment and Simulation Study.

Authors:  Guangmao Liu; Jianye Zhou; Hansong Sun; Yan Zhang; Haibo Chen; Shengshou Hu
Journal:  Med Sci Monit       Date:  2017-04-05

6.  Ventricular Flow Field Visualization During Mechanical Circulatory Support in the Assisted Isolated Beating Heart.

Authors:  P Aigner; M Schweiger; K Fraser; Y Choi; F Lemme; N Cesarovic; U Kertzscher; H Schima; M Hübler; M Granegger
Journal:  Ann Biomed Eng       Date:  2019-11-18       Impact factor: 3.934

7.  Research on Optimization Model of Multisource Traffic Information Collection Combination Based on Genetic Algorithm.

Authors:  Jianwei Guo; Yongbo Lv
Journal:  Comput Intell Neurosci       Date:  2022-01-27

8.  Experimental Validation of Enhanced Magnetic Resonance Imaging (EMRI) Using Particle Image Velocimetry (PIV).

Authors:  Giacomo Annio; Ryo Torii; Andrea Ducci; Vivek Muthurangu; Victor Tsang; Gaetano Burriesci
Journal:  Ann Biomed Eng       Date:  2021-06-28       Impact factor: 3.934

9.  Numerical investigation of the effect of cannula placement on thrombosis.

Authors:  ChiWei Ong; Socrates Dokos; BeeTing Chan; Einly Lim; Amr Al Abed; Noor Azuan Bin Abu Osman; Suhaini Kadiman; Nigel H Lovell
Journal:  Theor Biol Med Model       Date:  2013-05-16       Impact factor: 2.432

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.