Ungated nonenhanced radial quiescent interval slice-selective (QISS) magnetic resonance angiography of the neck: Evaluation of image quality.

Ioannis Koktzoglou1,2, Emily A Aherne1,3, Matthew T Walker1,2, Joel R Meyer1,2, Robert R Edelman1,3.   

Abstract

BACKGROUND: Standard-of-care time-of-flight (TOF) techniques for nonenhanced magnetic resonance angiography (NEMRA) of the carotid bifurcation and other cervical arteries often provide nondiagnostic image quality due to motion and flow artifacts.
PURPOSE: To perform an initial evaluation of an ungated radial quiescent-interval slice-selective (QISS) technique for NEMRA of the neck, in comparison with 2D TOF and contrast-enhanced magnetic resonance angiography (CEMRA). STUDY TYPE: Retrospective. POPULATION: Sixty patients referred for neck MR angiography. FIELD STRENGTH/SEQUENCE: Ungated radial QISS at 3T. ASSESSMENT: Three radiologists scored image quality of 18 arterial segments using a 4-point scale (1, nondiagnostic; 2, fair; 3, good; 4, excellent), and two radiologists graded proximal internal carotid stenosis using five categories (<50%, 50-69%, 70-99%, occlusion, nondiagnostic). STATISTICAL TESTS: Friedman tests with post-hoc Wilcoxon signed-rank tests; unweighted Gwet's AC1 statistic; tests for equality of proportions.
RESULTS: Ungated radial QISS provided image quality that significantly exceeded 2D TOF (mean scores of 2.7 vs. 2.0, 2.7 vs. 2.2, and 2.9 vs. 2.3; P < 0.001, all comparisons), while CEMRA provided the best image quality (mean scores of 3.6, 3.7, and 3.5 for the three reviewers). Interrater agreement of image quality scores was substantial for CEMRA (AC1 = 0.70, P < 0.001), and moderate for QISS (AC1 = 0.43, P < 0.001) and TOF (AC1 = 0.41, P < 0.001). Compared with TOF, QISS NEMRA provided a significantly higher percentage of diagnostic segments for all three reviewers (91.0% vs. 71.7%, 93.5% vs. 72.9%, 95.5% vs. 85.2%; P < 0.0001) and demonstrated better agreement with CEMRA for grading of proximal internal carotid stenosis (AC1 = 0.94 vs. 0.73 for reviewer 1, P < 0.05; AC1 = 0.89 vs. 0.68 for reviewer 2, P < 0.05). DATA
CONCLUSION: In this initial study, ungated radial QISS significantly outperformed 2D TOF for the evaluation of the neck arteries, with overall better image quality and more diagnostic arterial segments, and improved agreement with CEMRA for grading stenosis of the proximal internal carotid artery. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1798-1807.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  carotid bifurcation; magnetic resonance angiography; neck; nonenhanced; quiescent-interval slice-selective (QISS); time-of-flight

Mesh:

Substances:

Year:  2019        PMID: 31077477      PMCID: PMC7101236          DOI: 10.1002/jmri.26781

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  28 in total

Review 1.  Spontaneous dissection of the carotid and vertebral arteries.

Authors:  W I Schievink
Journal:  N Engl J Med       Date:  2001-03-22       Impact factor: 91.245

2.  Projection reconstruction techniques for reduction of motion effects in MRI.

Authors:  G H Glover; J M Pauly
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

3.  Computing inter-rater reliability and its variance in the presence of high agreement.

Authors:  Kilem Li Gwet
Journal:  Br J Math Stat Psychol       Date:  2008-05       Impact factor: 3.380

4.  MR angiography in carotid stenosis: a comparison of three techniques.

Authors:  T Scarabino; A Carriero; N Magarelli; F Florio; G M Giannatempo; L Bonomo; U Salvolini
Journal:  Eur J Radiol       Date:  1998-09       Impact factor: 3.528

5.  Carotid artery: prospective blinded comparison of two-dimensional time-of-flight MR angiography with conventional angiography and duplex US.

Authors:  J Huston; B D Lewis; D O Wiebers; F B Meyer; S J Riederer; A L Weaver
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

6.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

7.  Super-resolution intracranial quiescent interval slice-selective magnetic resonance angiography.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2017-05-03       Impact factor: 4.668

8.  Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: Technical considerations and clinical feasibility.

Authors:  Robert R Edelman; John J Sheehan; Eugene Dunkle; Nancy Schindler; James Carr; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

9.  Autopsy prevalence of proximal extracranial atherosclerosis in patients with fatal stroke.

Authors:  Mikael Mazighi; Julien Labreuche; Fernando Gongora-Rivera; Charles Duyckaerts; Jean-Jacques Hauw; Pierre Amarenco
Journal:  Stroke       Date:  2008-12-31       Impact factor: 7.914

10.  Diagnostic accuracy of contrast-enhanced MR angiography in severe carotid stenosis: meta-analysis with metaregression of different techniques.

Authors:  Jan Menke
Journal:  Eur Radiol       Date:  2009-04-28       Impact factor: 5.315

View more
  6 in total

1.  High spatial resolution whole-neck MR angiography using thin-slab stack-of-stars quiescent interval slice-selective acquisition.

Authors:  Ioannis Koktzoglou; Rong Huang; Archie L Ong; Pascale J Aouad; Matthew T Walker; Robert R Edelman
Journal:  Magn Reson Med       Date:  2020-06-10       Impact factor: 4.668

2.  Non-Contrast-Enhanced Carotid MRA: Clinical Evaluation of a Novel Ungated Radial Quiescent-Interval Slice-Selective MRA at 1.5T.

Authors:  S Peters; M Huhndorf; U Jensen-Kondering; N Larsen; I Koktzoglou; R R Edelman; J Graessner; M Both; O Jansen; M Salehi Ravesh
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-08       Impact factor: 3.825

3.  Imaging of the extracranial internal carotid artery in acute ischemic stroke: assessment of stenosis, plaques, and image quality using relaxation-enhanced angiography without contrast and triggering (REACT).

Authors:  Ulrike Cornelia Isabel Hoyer; Simon Lennartz; Nuran Abdullayev; Florian Fichter; Stephanie T Jünger; Lukas Goertz; Kai Roman Laukamp; Roman Johannes Gertz; Jan-Peter Grunz; Christopher Hohmann; David Maintz; Thorsten Persigehl; Christoph Kabbasch; Jan Borggrefe; Kilian Weiss; Lenhard Pennig
Journal:  Quant Imaging Med Surg       Date:  2022-07

4.  Feasibility of a sub-3-minute imaging strategy for ungated quiescent interval slice-selective MRA of the extracranial carotid arteries using radial k-space sampling and deep learning-based image processing.

Authors:  Ioannis Koktzoglou; Rong Huang; Archie L Ong; Pascale J Aouad; Emily A Aherne; Robert R Edelman
Journal:  Magn Reson Med       Date:  2020-01-23       Impact factor: 4.668

5.  High-resolution, non-contrast-enhanced magnetic resonance angiography of the wrist, hand and digital arteries using optimized implementation of Cartesian quiescent interval slice selective (QISS) at 1.5 T.

Authors:  Mona Salehi Ravesh; Annett Lebenatus; Alexandra Bonietzki; Johannes Hensler; Ioannis Koktzoglou; Robert R Edelman; Joachim Graessner; Olav Jansen; Marcus Both
Journal:  Magn Reson Imaging       Date:  2021-02-11       Impact factor: 2.546

6.  Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT) for Fast Imaging of Extracranial Arteries in Acute Ischemic Stroke at 3 T.

Authors:  Lenhard Pennig; Christoph Kabbasch; Ulrike Cornelia Isabel Hoyer; Simon Lennartz; David Zopfs; Lukas Goertz; Kai Roman Laukamp; Anton Wagner; Jan-Peter Grunz; Jonas Doerner; Thorsten Persigehl; Kilian Weiss; Jan Borggrefe
Journal:  Clin Neuroradiol       Date:  2020-10-07       Impact factor: 3.649

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.