S Peters1, M Huhndorf1, U Jensen-Kondering1, N Larsen1, I Koktzoglou2,3, R R Edelman2,4, J Graessner5, M Both1, O Jansen1, M Salehi Ravesh6. 1. From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany. 2. Department of Radiology (I.K., R.R.E.), NorthShore University Health System, Evanston, Illinois. 3. University of Chicago Pritzker School of Medicine (I.K.), Chicago, Illinois. 4. Northwestern University Feinberg School of Medicine (R.R.E.), Chicago, Illinois. 5. Siemens Healthcare (J.G.), Hamburg, Germany. 6. From the Department of Radiology and Neuroradiology (S.P., M.H., U.J.-K., N.L., M.B., O.J., M.S.R.), University Medical Center Schleswig-Holstein, Kiel University, Kiel, Germany Mona.Salehiravesh@uksh.de.
Abstract
BACKGROUND AND PURPOSE: Non-contrast-enhanced MRA techniques have experienced a renaissance due to the known correlation between the use of gadolinium-based contrast agents and the development of nephrogenic systemic fibrosis and the deposition of gadolinium in some brain regions. The purpose of this study was to assess the diagnostic performance of ungated non-contrast-enhanced radial quiescent-interval slice-selective MRA of the extracranial supra-aortic arteries in comparison with conventional contrast-enhanced MRA in patients with clinical suspicion of carotid stenosis. MATERIALS AND METHODS: In this prospective study, both MRA pulse sequences were performed in 31 consecutive patients (median age, 68.8 years; 19 men). For the evaluation, the cervical arterial system was divided into 35 segments (right and left side). Three blinded reviewers separately evaluated these segments. An ordinal scoring system was used to assess the image quality of arterial segments and the stenosis grading of carotid arteries. RESULTS: Overall venous contamination in quiescent-interval slice-selective MRA was rated as "none" by all readers in 84.9% of cases and in 8.1% of cases in contrast-enhanced MRA (P < .0001). The visualization quality of arterial segments was considered good to excellent in 40.2% for the quiescent-interval slice-selective MRA and in 52.2% for the contrast-enhanced MRA (P < .0001). The diagnostic accuracy of ungated quiescent-interval slice-selective MRA concerning the stenosis grading showed a total sensitivity and specificity of 85.7% and 90.0%, respectively. CONCLUSIONS: Ungated quiescent-interval slice-selective MRA can be used clinically as an alternative to contrast-enhanced MRA without a significantly different image quality or diagnostic accuracy for the detection of carotid stenosis at 1.5T.
BACKGROUND AND PURPOSE: Non-contrast-enhanced MRA techniques have experienced a renaissance due to the known correlation between the use of gadolinium-based contrast agents and the development of nephrogenic systemic fibrosis and the deposition of gadolinium in some brain regions. The purpose of this study was to assess the diagnostic performance of ungated non-contrast-enhanced radial quiescent-interval slice-selective MRA of the extracranial supra-aortic arteries in comparison with conventional contrast-enhanced MRA in patients with clinical suspicion of carotid stenosis. MATERIALS AND METHODS: In this prospective study, both MRA pulse sequences were performed in 31 consecutive patients (median age, 68.8 years; 19 men). For the evaluation, the cervical arterial system was divided into 35 segments (right and left side). Three blinded reviewers separately evaluated these segments. An ordinal scoring system was used to assess the image quality of arterial segments and the stenosis grading of carotid arteries. RESULTS: Overall venous contamination in quiescent-interval slice-selective MRA was rated as "none" by all readers in 84.9% of cases and in 8.1% of cases in contrast-enhanced MRA (P < .0001). The visualization quality of arterial segments was considered good to excellent in 40.2% for the quiescent-interval slice-selective MRA and in 52.2% for the contrast-enhanced MRA (P < .0001). The diagnostic accuracy of ungated quiescent-interval slice-selective MRA concerning the stenosis grading showed a total sensitivity and specificity of 85.7% and 90.0%, respectively. CONCLUSIONS: Ungated quiescent-interval slice-selective MRA can be used clinically as an alternative to contrast-enhanced MRA without a significantly different image quality or diagnostic accuracy for the detection of carotid stenosis at 1.5T.
Authors: E K Yucel; C M Anderson; R R Edelman; T M Grist; R A Baum; W J Manning; A Culebras; W Pearce Journal: Circulation Date: 1999-11-30 Impact factor: 29.690
Authors: Robert W Hobson; William C Mackey; Enrico Ascher; M Hassan Murad; Keith D Calligaro; Anthony J Comerota; Victor M Montori; Mark K Eskandari; Douglas W Massop; Ruth L Bush; Brajesh K Lal; Bruce A Perler Journal: J Vasc Surg Date: 2008-08 Impact factor: 4.268
Authors: J Weber; P Veith; B Jung; G Ihorst; O Moske-Eick; S Meckel; H Urbach; C A Taschner Journal: Clin Neuroradiol Date: 2014-01-03 Impact factor: 3.649
Authors: Harald Kramer; Val M Runge; John N Morelli; Kenneth D Williams; L Gill Naul; Konstantin Nikolaou; Maximilian F Reiser; Bernd J Wintersperger Journal: Eur Radiol Date: 2011-04-09 Impact factor: 5.315
Authors: Robert R Edelman; John J Sheehan; Eugene Dunkle; Nancy Schindler; James Carr; Ioannis Koktzoglou Journal: Magn Reson Med Date: 2010-04 Impact factor: 4.668
Authors: Matthew L Flaherty; Brett Kissela; Jane C Khoury; Kathleen Alwell; Charles J Moomaw; Daniel Woo; Pooja Khatri; Simona Ferioli; Opeolu Adeoye; Joseph P Broderick; Dawn Kleindorfer Journal: Neuroepidemiology Date: 2012-10-11 Impact factor: 3.282
Authors: Ioannis Koktzoglou; Rong Huang; Archie L Ong; Pascale J Aouad; Matthew T Walker; Robert R Edelman Journal: Magn Reson Med Date: 2020-06-10 Impact factor: 4.668
Authors: Ulrike Cornelia Isabel Hoyer; Simon Lennartz; Nuran Abdullayev; Florian Fichter; Stephanie T Jünger; Lukas Goertz; Kai Roman Laukamp; Roman Johannes Gertz; Jan-Peter Grunz; Christopher Hohmann; David Maintz; Thorsten Persigehl; Christoph Kabbasch; Jan Borggrefe; Kilian Weiss; Lenhard Pennig Journal: Quant Imaging Med Surg Date: 2022-07
Authors: Ioannis Koktzoglou; Rong Huang; Archie L Ong; Pascale J Aouad; Emily A Aherne; Robert R Edelman Journal: Magn Reson Med Date: 2020-01-23 Impact factor: 4.668
Authors: Lenhard Pennig; Christoph Kabbasch; Ulrike Cornelia Isabel Hoyer; Simon Lennartz; David Zopfs; Lukas Goertz; Kai Roman Laukamp; Anton Wagner; Jan-Peter Grunz; Jonas Doerner; Thorsten Persigehl; Kilian Weiss; Jan Borggrefe Journal: Clin Neuroradiol Date: 2020-10-07 Impact factor: 3.649