| Literature DB >> 31040552 |
Vijeta Gajbhiye1, Rajlakshmi Banerjee1, Priti Jaiswal1, Anuj Chandak1, Usha Radke1.
Abstract
AIM: Displacement of gingiva is essential for obtaining accurate impressions for the fabrication of fixed prostheses, particularly when the finish line is at or within the gingival sulcus. Various newer impression materials have been introduced to achieve gingival displacement while recording the impressions. A comparative evaluation of these new gingival displacement materials was deemed necessary for efficacy in tissue management and dimensional accuracy.Entities:
Keywords: Dimensional accuracy; gingival displacement; impression
Year: 2019 PMID: 31040552 PMCID: PMC6482624 DOI: 10.4103/jips.jips_285_18
Source DB: PubMed Journal: J Indian Prosthodont Soc ISSN: 0972-4052
Latin block design
| Subject | Day 1 | Day 2 | Day 12 | Day 22 |
|---|---|---|---|---|
| 1 | C | R | N | A |
| 2 | C | A | R | N |
| 3 | C | N | A | R |
| - | - | - | - | - |
| - | - | - | - | - |
| - | - | - | - | - |
| 18 | C | N | A | R |
| 19 | C | R | N | A |
| 20 | C | A | R | N |
Figure 1Reference points for measurements for dimensional accuracy
Figure 2Measurements made to evaluate dimensional accuracy using Vernier caliper
Figure 3Marking and die cutting for measuring gingival displacement under optical microscope
Figure 4Viewing gingival displacement under optical microscope
Graph 1Change in sulcus width produced by Retraction cord, NoCord, and Aquasil
Mean change in sulcus width
| Retraction Methods | Mean (mm) | Standard deviation | |
|---|---|---|---|
| Retraction Cord | 10 | 0.27 | 0.02 |
| NoCord | 10 | 0.26 | 0.02 |
| Aquasil | 10 | 0.22 | 0.02 |
Comparison of change in sulcus width using post-hoc test
| Retraction method | Comparison group | Level of significance |
|---|---|---|
| Retraction Produced | Nocord | 1.000 |
| Retraction Cord | Aquasil | <0.0001** |
| Retraction Cord | 1.000 | |
| Nocord | Aquasil | <0.0001** |
| Retraction Cord | <0.0001** | |
| Aquasil | Nocord | <0.0001** |
**Highly Significant (P<0.05 is significant)
Mean change in sulcus depth using one-way ANOVA
| Retraction methods | Mean (mm) | Standard deviation | |
|---|---|---|---|
| Retraction Cord | 10 | 0.299 | 0.04 |
| NoCord | 10 | 0.231 | 0.04 |
| Aquasil | 10 | 0.195 | 0.04 |
Graph 2Change in sulcus depth obtained with all three methods
Graph 3Mean measurements for dimensional accuracy
Level of significance of change in width using Wilcoxon’s signed test and paired t-test
| Retraction methods | Significance of Change in width produced (Pre-retraction to Post retraction) |
|---|---|
| Retraction Cord | <0.002** |
| NoCord | <0.002** |
| Aquasil | <0.002** |