Literature DB >> 23771446

Accuracy of impressions with different impression materials in angulated implants.

S Reddy1, K Prasad, H Vakil, A Jain, R Chowdhary.   

Abstract

PURPOSE: To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants.
MATERIALS AND METHODS: Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast.
RESULTS: Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants.
CONCLUSION: On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23771446     DOI: 10.4103/1119-3077.113447

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  6 in total

1.  Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions.

Authors:  Ahmad Ghahremanloo; Mahdieh Seifi; Jalil Ghanbarzade; Seyyed Mohammad Abrisham; Rashid Abdolah Javan
Journal:  J Dent (Tehran)       Date:  2017-01

2.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01

3.  Comparative evaluation of three gingival displacement materials for efficacy in tissue management and dimensional accuracy.

Authors:  Vijeta Gajbhiye; Rajlakshmi Banerjee; Priti Jaiswal; Anuj Chandak; Usha Radke
Journal:  J Indian Prosthodont Soc       Date:  2019 Apr-Jun

4.  Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations.

Authors:  Abbass Fallah Tafti; Mahnaz Hatami; Foroughsadat Razavi; Behnaz Ebadian
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

5.  Custom abutments on tilted implants in the maxilla: A clinical report.

Authors:  Fabrizio Di Francesco; Gennaro De Marco; Attilio Sommella; Alessandro Lanza
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14

6.  Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge after Digital Impression.

Authors:  Mahnaz Arshad; Amirmohsen Asgari; Mohamad Javad Kharazifard; Narges Ameri
Journal:  Int J Dent       Date:  2022-01-25
  6 in total