Literature DB >> 12589285

In vitro kinetic study of absorbency of retraction cords.

Ferenc Csempesz1, János Vág, Arpád Fazekas.   

Abstract

STATEMENT OF PROBLEM: The soaking time required for liquid uptake by retraction cords is a crucial factor in the successful gingival retraction procedure.
PURPOSE: The aim of this investigation was to determine the optimal soaking time for 3 retraction cords of different thickness to ensure adequate uptake of the hemostatic solution.
MATERIAL AND METHODS: Braided ULTRAPAC retraction cords of 3 different thicknesses (No. 00, No. 0, and No. 1) with identical lengths (35 mm) were used. The capability of the cords to absorb liquids was measured by a gravimetric method. Different sulcus retraction solutions (epinephrine, aluminum chloride, and ferric sulfate) were tested, with physiological saline solution used as the control. The cords were soaked for various time intervals (2 seconds; 1, 5, and 60 minutes; and 24 hours) in the medicament solutions at room temperature. Immediately before immersion, air inclusions that may have inhibited the inner moistening of the cords were manually pressed out. In each of the 4 treatment groups, 75 pieces of cord were tested by determining the grams of fluid absorbed by grams of dry cord (gram/gram). Before the cord was weighed, excess fluid accumulating on the outer surface of the cord was removed by filter paper saturated in the corresponding test solution. The data were analyzed by F test analysis, and P<.05 was regarded as significant.
RESULTS: In each group, regardless of the cord type (No. 00, No. 0, or No. 1) or medicament solutions tested, the amount of fluid absorbed increased with the soaking time, but to different extents. A logarithmic relationship in a linear plot between the amount of fluid absorbed and the soaking time was demonstrated. The relationship established offered an exact determination of both the rate and the saturation level of liquid uptake. The rate of liquid uptake calculated from the saturation equations exhibited significant correlation with the cord thickness (P<.05). The saturation levels of the solutions did not show correlation with the cord thickness (P>.30).
CONCLUSION: Within the limitations of this study, the results indicated that 20 minutes of soaking time was necessary for saturation of the cords before use, provided that air trapped within the cords was removed. In addition to the soaking time, the saturation of the cords with the solutions largely depended on the wetting of the cords.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12589285     DOI: 10.1067/mpr.2003.61

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Evaluation of Fluid Absorbency of Retraction Cords after Immersing in Two Retraction Medicaments - An In-vitro Study.

Authors:  Gautam Vishnubhotla; Sreeramulu Basapogu; Rajeev Kumar Reddy Karnati; Pradeep Prabhu Dasari; Mani Victor Thommandru; Mohana Bindu Bethu
Journal:  J Clin Diagn Res       Date:  2016-11-01

2.  Comparison of the effect of different medicaments on surface reproduction of two commercially available Polyvinyl Siloxane impression materials - An Invitro Study.

Authors:  Rina Singh; Jagjit Singh; Ramandeep S Gambhir; Ramanpreet Singh; Sonia Nanda
Journal:  J Clin Exp Dent       Date:  2013-07-01

Review 3.  Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review.

Authors:  Safari S; Vossoghi Sheshkalani Ma; Vossoghi Sheshkalani Mi; Hoseini Ghavam F; Hamedi M
Journal:  J Dent Biomater       Date:  2016-06

4.  Evaluation of antioxidant and antimutagenic activities of aluminum chloride.

Authors:  Nurdan Sarac; Aysel Ugur; Inci Karaca
Journal:  Eur Oral Res       Date:  2019-05-01

5.  Comparative evaluation of three gingival displacement materials for efficacy in tissue management and dimensional accuracy.

Authors:  Vijeta Gajbhiye; Rajlakshmi Banerjee; Priti Jaiswal; Anuj Chandak; Usha Radke
Journal:  J Indian Prosthodont Soc       Date:  2019 Apr-Jun

6.  A comparative evaluation of amount of gingival displacement produced by four different gingival displacement agents - An in vivo study.

Authors:  Zainab Ilyas Kesari; Jyoti Tipin Karani; Saloni Sharad Mistry; Ashutosh Ramesh Pai
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10
  6 in total