Effect of compliance mismatch on flow disturbances in a model of an arterial graft replacement.

F Miyawaki1, T V How, D Annis.   

Abstract

Flow disturbances in a model of an interposition graft in an arterial segment were measured using an ultrasound Doppler velocimeter. The effect of the degree of compliance mismatch between a stiff' graft' and compliant 'arterial' segments was investigated. In steady flow, disturbances were detected when the compliance ratio (stiff to compliant segments) was less than or equal to 0.1 and the Reynolds number greater than or equal to 2200. A recirculation zone just downstream of the distal anastomosis was observed at a Reynolds number greater than or equal to 2400. Disturbances were also measured under pulsatile flow which consisted of a time-varying component superimposed on a steady flow component. The time-varying flow component was either quasiphysiological or sinusoidal in shape. The Reynolds number was 500 but the frequency parameter varied from 4.2 to 8.5. Significant disturbances were observed for conduits with compliance ratio less than or equal to 0.19. The disturbance intensity tended to increase as the compliance ratio decreased and the frequency parameter increased. The magnitude of the disturbance was also greater with the quasiphysiological than the sinusoidal input flow waveform.

Mesh:

Year:  1990        PMID: 2277546     DOI: 10.1007/bf02441969

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  26 in total

1.  Effect of compliance mismatch on vascular graft patency.

Authors:  W M Abbott; J Megerman; J E Hasson; G L'Italien; D F Warnock
Journal:  J Vasc Surg       Date:  1987-02       Impact factor: 4.268

2.  Pulsed Doppler ultrasound system for the measurement of velocity distributions and flow disturbances in arterial prostheses.

Authors:  R A Black; T V How
Journal:  J Biomed Eng       Date:  1989-01

3.  Poststenotic flow disturbance in the dog aorta as measured with pulsed Doppler ultrasound.

Authors:  N Talukder; J T Fulenwider; R F Mabon; D P Giddens
Journal:  J Biomech Eng       Date:  1986-08       Impact factor: 2.097

4.  Transcutaneous measurement of the elastic properties of the human femoral artery.

Authors:  D J Mozersky; D S Sumner; D E Hokanson; D E Strandness
Journal:  Circulation       Date:  1972-11       Impact factor: 29.690

5.  Velocity measurements in steady flow through axisymmetric stenoses at moderate Reynolds numbers.

Authors:  S A Ahmed; D P Giddens
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

6.  Intimal hyperplasia and neointima: An ultrastructural analysis of thrombosed grafts in humans.

Authors:  V S Sottiurai; J S Yao; W R Flinn; R C Batson
Journal:  Surgery       Date:  1983-06       Impact factor: 3.982

7.  Current PTFE grafts: a biomechanical, scanning electron, and light microscopic evaluation.

Authors:  K C Hanel; C McCabe; W M Abbott; J Fallon; J Megerman
Journal:  Ann Surg       Date:  1982-04       Impact factor: 12.969

8.  Current status of vascular grafts.

Authors:  A D Callow
Journal:  Surg Clin North Am       Date:  1982-06       Impact factor: 2.741

9.  An elastomeric vascular prosthesis.

Authors:  D Annis; A Bornat; R O Edwards; A Higham; B Loveday; J Wilson
Journal:  Trans Am Soc Artif Intern Organs       Date:  1978

10.  Effect of suture technique on arterial anastomotic compliance.

Authors:  S R Klein; L Goldberg; R M Miranda; P Bosco; R J Nelson; R A White
Journal:  Arch Surg       Date:  1982-01
View more
  5 in total

1.  Comparative analysis of the biaxial mechanical behavior of carotid wall tissue and biological and synthetic materials used for carotid patch angioplasty.

Authors:  Alexey V Kamenskiy; Iraklis I Pipinos; Jason N MacTaggart; Syed A Jaffar Kazmi; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

2.  Biaxial Stretch Improves Elastic Fiber Maturation, Collagen Arrangement, and Mechanical Properties in Engineered Arteries.

Authors:  Angela H Huang; Jenna L Balestrini; Brooks V Udelsman; Kevin C Zhou; Liping Zhao; Jacopo Ferruzzi; Barry C Starcher; Michael J Levene; Jay D Humphrey; Laura E Niklason
Journal:  Tissue Eng Part C Methods       Date:  2016-06       Impact factor: 3.056

3.  Haemodynamic model of a unilateral iliac stenosis with an aortoiliac bypass.

Authors:  M A Helal; K C Watts; A E Marble
Journal:  Med Biol Eng Comput       Date:  1993-11       Impact factor: 2.602

4.  Prosthetic aortic graft replacement of the ascending thoracic aorta alters biomechanics of the native descending aorta as assessed by transthoracic echocardiography.

Authors:  Maria C Palumbo; Lisa Q Rong; Jiwon Kim; Pedram Navid; Razia Sultana; Jonathan Butcher; Alberto Redaelli; Mary J Roman; Richard B Devereux; Leonard N Girardi; Mario F L Gaudino; Jonathan W Weinsaft
Journal:  PLoS One       Date:  2020-03-12       Impact factor: 3.240

5.  Tissue engineering of acellular vascular grafts capable of somatic growth in young lambs.

Authors:  Zeeshan Syedain; Jay Reimer; Matthew Lahti; James Berry; Sandra Johnson; Robert T Tranquillo
Journal:  Nat Commun       Date:  2016-09-27       Impact factor: 14.919

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.