| Literature DB >> 31023382 |
Edith B Milanzi1, Gerard H Koppelman2,3, Marieke Oldenwening1, Sonja Augustijn4, Bernadette Aalders-de Ruijter5, Martijn Farenhorst4, Judith M Vonk3,6, Marjan Tewis1, Bert Brunekreef1,7, Ulrike Gehring8.
Abstract
BACKGROUND: Spirometric lung function measurements have been proven to be excellent objective markers of respiratory morbidity. The use of different types of spirometers in epidemiological and clinical studies may present systematically different results affecting interpretation and implication of results. We aimed to explore considerations in the use of different spirometers in epidemiological studies by comparing forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) measurements between the Masterscreen pneumotachograph and EasyOne spirometers. We also provide a correction equation for correcting systematic differences using regression calibration.Entities:
Keywords: Calibration; Epidemiological studies; Lung function; Spirometry; Systematic difference
Year: 2019 PMID: 31023382 PMCID: PMC6485068 DOI: 10.1186/s12940-019-0478-2
Source DB: PubMed Journal: Environ Health ISSN: 1476-069X Impact factor: 5.984
Study population characteristics
| Masterscreen vs EasyOne1 | Overall ( | Males ( | Females( |
| Age (years) – mean (SD) | 30.2 (10.9) | 29.2 (10.8) | 30.8 (11.1) |
| Age ≤ 30 years – N (%) | 32 (65) | 12 (66) | 29 (67) |
| Ethnicity-N (%) | |||
| Caucasian | 49 (100) | 15 (100) | 34 (100) |
| Weight (Kg) – mean (SD) | 68.9 (11.3) | 72.6 (11.9) | 66.9 (10.6) |
| Height (m) – mean (SD) | 1.74 (8.32) | 1.81 (6.46) | 1.70 (6.57) |
| FEV1Masterscreen (L) – mean (SD) | 3.78 (0.63) | 4.38 (0.62) | 3.51(0.43) |
| FEV1EasyOne 1 – mean (SD) | 3.54 (0.60) | 4.11 (0.57) | 3.29 (0.42) |
| FVC Masterscreen (L) – mean (SD) | 4.78 (0.85) | 5.77 (0.76) | 4.35 (0.42) |
| FVCEasyOne1 (L) – mean (SD) | 4.41 (0.83) | 5.35 (0.74) | 4.01 (0.44) |
| FEV1Masterscreen mean (SD) percent predicted | 98.3 (11.1) | 93.6 (10.5) | 100.4 (10.8) |
| FEV1EasyOne1 mean (SD) percent predicted | 92.3 (10.8) | 87.9 (9.9) | 94.2 (10.7) |
| FVC Masterscreen mean (SD) percent predicted | 103.7 (10.5) | 101.2 (11.4) | 104 (10.1) |
| FVC EasyOne1 mean (SD) percent predicted | 95.5 (10.5) | 93.8 (12.2) | 96.2 (9.87) |
| EasyOne1 vs EasyOne2 | Overall ( | Males ( | Females ( |
| Age (years) - mean (SD) | 35.1 (11.4) | 32.8 (10.4) | 37.4 (12.1) |
| Age ≤ 30 years – N (%) | 23 (46) | 11 (47) | 12 (52) |
| Ethnicity- N (%) | |||
| Caucasian | 43 (88) | 15 (88) | 28 (88) |
| Asian | 4 (8) | 2 (12) | 2 (6) |
| Other | 2 (4) | 0 (0) | 2 (6) |
| Weight (Kg) – mean (SD) | 68.1 (10.1) | 76.1 (9.3) | 63.7 (7.7) |
| Height (m) – mean (SD) | 1.71 (0.11) | 1.82 (0.72) | 1.65 (0.86) |
| FEV1EasyOne 1(L) – mean (SD) | 3.50 (0.85) | 4.33 (0.63) | 3.05 (0.58) |
| FEV1EasyOne 2 (L) – mean (SD) | 3.46 (0.84) | 4.27 (0.62) | 3.03 (0.58) |
| FVCEasyOne1(L) – mean (SD) | 4.31 (1.05) | 5.45 (0.64) | 3.71 (0.65) |
| FVCEasyOne2 (L) – mean (SD) | 4.27 (1.04) | 5.38 (0.65) | 3.68 (0.66) |
| FEV1 EasyOne1 mean (SD) percent predicted | 95.8 (11.1) | 92.8 (12.2) | 97.4 (10.2) |
| FEV1 EasyOne2 mean (SD) percent predicted | 94.8 (11.2) | 91.5 (12.1) | 96.5 (10.5) |
| FVCEasyOne1mean (SD) percent predicted | 97.4 (9.9) | 96.1 (11.1) | 98.1 (9.3) |
| FVCEasyOne2mean (SD) percent predicted | 96.5 (10.2) | 94.8 (11.1) | 97.4 (9.7) |
Mean differences (with confidence intervals): Masterscreen vs EasyOne1 and EasyOne1 vs EasyOne2, overall and by age and sex
| FEV1 (L) | FVC (L) | ||||
|---|---|---|---|---|---|
| N | Mean diff. | 95% CI | Mean diff. | 95% CI | |
| Masterscreen –EasyOne1 | |||||
| Overall | 49 | 0.24 | (0.19;0.26) | 0.37 | (0.33; 0.41) |
| ≤ 30 years | 32 | 0.23 | (0.18; 0.27) | 0.37 | (0.31; 0.42) |
| > 30 years | 17 | 0.23 | (0.17; 0.29) | 0.38 | (0.33; 0.44) |
| Males | 15 | 0.26 | (0.18; 0.35) | 0.42 | (0.31; 0.53) |
| Females | 34 | 0.21 | (0.18; 0.24) | 0.35 | (0.31; 0.39) |
| EasyOne1 –EasyOne2 | |||||
| Overall | 49 | 0.03 | (0.01;0.06) | 0.04 | (0.01; 0.06) |
| ≤ 30 years | 23 | 0.03 | (−0.00; 0.08) | 0.04 | (0.00; 0.08) |
| > 30 years | 26 | 0.03 | (0.00; 0.06) | 0.03 | (−0.00; 0.07) |
| Males | 17 | 0.06 | (0.00; 0.11) | 0.06 | (0.01; 0.12) |
| Females | 32 | 0.02 | (0.00; 0.05) | 0.02 | (− 0.00;0.05) |
Fig. 1Correlation between measurements from the first comparison series (Masterscreen and EasyOne1 spirometer, upper panels) and the second series (EasyOne1 spirometer from the first series and another EasyOne2 spirometer of the same generation, lower panel)
Fig. 2Bland and Altman plots of FEV1 and FVC measurements from the first test series (Masterscreen and EasyOne1 spirometer, upper panels) and the second test series (EasyOne1 spirometer from the first series and another EasyOne2 spirometer of the same generation, lower panel)
Means of corrected lung function measurements from PIAMA lung function data
| Uncorrected Mean (95% CI) | Corrected Mean (95% CI) | |
|---|---|---|
| Overall FEV1 (L) | 3.81 (3.75; 3.86) | 3.94 (3.89; 4.00) |
| FEV1_EasyOne1 (L) | 3.65 (3.58; 3.72) | 3.88 (3.81; 3.95) |
| FEV1_Masterscreen (L) | 4.03 (3.95; 4.11) | 4.03 (3.95; 4.11) |
| Mean difference (L) | −0.37 (− 0.47; − 0.26) | −0.13 (− 0.24; − 0.03) |
| Overall FVC (L) | 4.48 (4.42; 4.55) | 4.70 (4.64; 4.77) |
| FVC_EasyOne1 (L) | 4.30 (4.21; 4.38) | 4.67 (4.59;4.76) |
| FVC_Masterscreen (L) | 4.74 (4.64; 4.84) | 4.74 (4.64; 4.84) |
| Mean difference (L) | −0.44 (− 0.56; − 0.31) | −0.07 (− 0.19; 0.07) |