Literature DB >> 30989406

Fluorometric determination of cardiac myoglobin based on energy transfer from a pyrene-labeled aptamer to graphene oxide.

Dongkui Liu1,2, Yanbo Zeng1, Guobao Zhou1, Xing Lu1, Dongwei Miao1,2, Yiwen Yang3, Yunyun Zhai1, Jian Zhang1, Zulei Zhang1, Hailong Wang1, Lei Li4.   

Abstract

The authors describe a fluorometric assay for cardiac myoglobin (Mb), a marker for myocardial infarction. An Mb-binding aptamer was labeled with pyrene and adsorbed on the surface of graphene oxide (GO) via noncovalent and reversible binding forces. This causes the fluorescence of pyrene (best measured at excitation/emission wavelengths of 275/376 nm) to be quenched. However, fluorescence is restored on addition of pyrene due to the strong affinity between Mb and aptamer which causes its separation from GO. Fluorescence increases linearly in the 5.6-450 pM Mb concentration range, and the lower detection limit is 3.9 pM (S/N = 3). The assay was applied to the determination of cardiac Mb in spiked serum, and satisfactory results were obtained. Graphical abstract Schematic presentation of the detection of Mb (cardiac myoglobin) by using a fluorometric method based on pyrene-modified anti-Mb aptamer and GO (graphene oxide) through fluorescence quenching and subsequent recovery.

Entities:  

Keywords:  Chemical modifications; FRET; Fluorescent recovery; Fluorophore; PMAMA probe

Mesh:

Substances:

Year:  2019        PMID: 30989406     DOI: 10.1007/s00604-019-3385-x

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  21 in total

1.  Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4 DNA polymerase.

Authors:  C Tuerk; L Gold
Journal:  Science       Date:  1990-08-03       Impact factor: 47.728

2.  Photophysics of pyrene-labelled compounds of biophysical interest.

Authors:  Chunxiang Yao; Heinz-Bernhard Kraatz; Ronald P Steer
Journal:  Photochem Photobiol Sci       Date:  2004-12-06       Impact factor: 3.982

Review 3.  Analytical applications of aptamers.

Authors:  S Tombelli; M Minunni; M Mascini
Journal:  Biosens Bioelectron       Date:  2004-12-16       Impact factor: 10.618

4.  Long range resonance energy transfer from a dye molecule to graphene has (distance)(-4) dependence.

Authors:  R S Swathi; K L Sebastian
Journal:  J Chem Phys       Date:  2009-02-28       Impact factor: 3.488

5.  Iminodiacetic acid-functionalized gold nanoparticles for optical sensing of myoglobin via Cu2+ coordination.

Authors:  Xianfeng Zhang; Xianming Kong; Wenjuan Fan; Xuezhong Du
Journal:  Langmuir       Date:  2011-04-13       Impact factor: 3.882

6.  Plasmonic DNA hotspots made from tungsten disulfide nanosheets and gold nanoparticles for ultrasensitive aptamer-based SERS detection of myoglobin.

Authors:  Munish Shorie; Vinod Kumar; Harmanjit Kaur; Kulvinder Singh; Vijay K Tomer; Priyanka Sabherwal
Journal:  Mikrochim Acta       Date:  2018-02-05       Impact factor: 5.833

7.  Fabrication of biomembrane-like films on carbon electrodes using alkanethiol and diazonium salt and their application for direct electrochemistry of myoglobin.

Authors:  Saima Anjum; Wenjing Qi; Wenyue Gao; Jianming Zhao; Saima Hanif; Guobao Xu
Journal:  Biosens Bioelectron       Date:  2014-10-18       Impact factor: 10.618

8.  Immunoassays for serum and urine myoglobin: myoglobin clearance assessed as a risk factor for acute renal failure.

Authors:  A H Wu; I Laios; S Green; T G Gornet; S S Wong; L Parmley; A S Tonnesen; B Plaisier; R Orlando
Journal:  Clin Chem       Date:  1994-05       Impact factor: 8.327

9.  Sensitive point-of-care monitoring of cardiac biomarker myoglobin using aptamer and ubiquitous personal glucose meter.

Authors:  Qing Wang; Fang Liu; Xiaohai Yang; Kemin Wang; Hui Wang; Xin Deng
Journal:  Biosens Bioelectron       Date:  2014-09-03       Impact factor: 10.618

10.  A graphene platform for sensing biomolecules.

Authors:  Chun-Hua Lu; Huang-Hao Yang; Chun-Ling Zhu; Xi Chen; Guo-Nan Chen
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

View more
  1 in total

Review 1.  Immobilization Techniques for Aptamers on Gold Electrodes for the Electrochemical Detection of Proteins: A Review.

Authors:  Franziska V Oberhaus; Dieter Frense; Dieter Beckmann
Journal:  Biosensors (Basel)       Date:  2020-04-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.