Literature DB >> 25216451

Sensitive point-of-care monitoring of cardiac biomarker myoglobin using aptamer and ubiquitous personal glucose meter.

Qing Wang1, Fang Liu1, Xiaohai Yang1, Kemin Wang2, Hui Wang1, Xin Deng1.   

Abstract

Myoglobin (Myo), which is one of the early markers to increase after acute myocardial infarction (AMI), plays a major role in urgent diagnosis of cardiovascular diseases. Hence, monitoring of Myo in point-of-care is fundamental. Here, a novel assay for sensitive and selective detection of Myo was introduced using a personal glucose meter (PGM) as readout. In the presence of Myo, the anti-Myo antibody immobilized on the surface of polystyrene microplate could capture the target Myo. Then the selected aptamer against Myo, which was obtained using our screening process, was conjugated with invertase, and such aptamer-invertase conjugates bound to the immobilized Myo due to the Myo/aptamer interaction. Subsequently, the resulting "antibody-Myo-aptamer sandwich" complex containing invertase conjugates hydrolyzed sucrose into glucose, thus establishing direct correlation between the Myo concentration and the amount of glucose measured by PGM. By employing the enzyme amplification, as low as 50 pM Myo could be detected. This assay also showed high selectivity for Myo and was successfully used for Myo detection in serum samples. This work may provide a simple but reliable tool for early diagnosis of AMI in the world, especially in developing countries.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Glucose meter; Invertase; Myoglobin; Point-of-care

Mesh:

Substances:

Year:  2014        PMID: 25216451     DOI: 10.1016/j.bios.2014.08.079

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  14 in total

1.  Electroanalysis of myoglobin based on electropolymerized molecularly imprinted polymer poly-o-phenylenediamine and carbon nanotubes/screen printed electrode.

Authors:  V V Shumyantseva; T V Bulko; L V Sigolaeva; A V Kuzikov; A I Archakov
Journal:  Dokl Biochem Biophys       Date:  2016-07-15       Impact factor: 0.788

Review 2.  Trends in the Design and Development of Specific Aptamers Against Peptides and Proteins.

Authors:  Maryam Tabarzad; Marzieh Jafari
Journal:  Protein J       Date:  2016-04       Impact factor: 2.371

3.  Fluorometric determination of cardiac myoglobin based on energy transfer from a pyrene-labeled aptamer to graphene oxide.

Authors:  Dongkui Liu; Yanbo Zeng; Guobao Zhou; Xing Lu; Dongwei Miao; Yiwen Yang; Yunyun Zhai; Jian Zhang; Zulei Zhang; Hailong Wang; Lei Li
Journal:  Mikrochim Acta       Date:  2019-04-15       Impact factor: 5.833

Review 4.  Transforming the blood glucose meter into a general healthcare meter for in vitro diagnostics in mobile health.

Authors:  Tian Lan; Jingjing Zhang; Yi Lu
Journal:  Biotechnol Adv       Date:  2016-03-03       Impact factor: 14.227

5.  Design, Synthesis, and Characterization of Small-Molecule Reagents That Cooperatively Provide Dual Readouts for Triaging and, When Necessary, Quantifying Point-of-Need Enzyme Assays.

Authors:  Adam D Brooks; Hemakesh Mohapatra; Scott T Phillips
Journal:  J Org Chem       Date:  2015-10-16       Impact factor: 4.354

6.  Nanostructured aptamer-based sensing platform for highly sensitive recognition of myoglobin.

Authors:  Neda Ghafori Nia; Azadeh Azadbakht
Journal:  Mikrochim Acta       Date:  2018-06-21       Impact factor: 5.833

7.  Electrochemical Aptasensor for Myoglobin-Specific Recognition Based on Porphyrin Functionalized Graphene-Conjugated Gold Nanocomposites.

Authors:  Guojuan Zhang; Zhiguang Liu; Li Wang; Yujing Guo
Journal:  Sensors (Basel)       Date:  2016-10-28       Impact factor: 3.576

8.  A Multi-Region Magnetoimpedance-Based Bio-Analytical System for Ultrasensitive Simultaneous Determination of Cardiac Biomarkers Myoglobin and C-Reactive Protein.

Authors:  Zhen Yang; Huanhuan Wang; Pengfei Guo; Yuanyuan Ding; Chong Lei; Yongsong Luo
Journal:  Sensors (Basel)       Date:  2018-06-01       Impact factor: 3.576

Review 9.  Electrochemical Aptasensors: Current Status and Future Perspectives.

Authors:  Ragaa Abd-Ellatief; Maha Ragaa Abd-Ellatief
Journal:  Diagnostics (Basel)       Date:  2021-01-11

10.  Ultrasensitive, Label Free, Chemiresistive Nanobiosensor Using Multiwalled Carbon Nanotubes Embedded Electrospun SU-8 Nanofibers.

Authors:  Matta Durga Prakash; Siva Rama Krishna Vanjari; Chandra Shekhar Sharma; Shiv Govind Singh
Journal:  Sensors (Basel)       Date:  2016-08-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.